Input data | AC operation Nominal input voltage range: 3x 400 VAC ... 500 VAC Input voltage range: 3x 320 VAC ... 575 VAC 2x 360 VAC ... 575 VAC (for 2-phase operation) Input voltage range AC: 3x 320 VAC ... 575 VAC 2x 360 VAC ... 575 VAC (for 2-phase operation) Voltage type of supply voltage: AC Inrush current: < 20 A Inrush current integral (I2t): 1.3 A2s AC frequency range: 45 Hz ... 65 Hz Mains buffering time: > 16 ms (400VAC) > 20 ms (480VAC) Current consumption: 3x 2 A (400VAC) 3x 1.6 A (480VAC) Nominal power consumption: 1387 VA Protective circuit: Transient surge protection; Varistor Power factor (cos phi): 0.76 Typical response time: < 1 s Permissible backup fuse: B10 B16 Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K) Discharge current to PE: < 3.5 mA |
Output data | Efficiency: > 91.5 % (at 400 V AC and nominal values) Output characteristic: U/I Nominal output voltage: 24 VDC ±1% Setting range of the output voltage (USet): 22.5 VDC ... 29.5 VDC (> 24 VDC, constant capacity restricted) Nominal output current (IN): 40 A (-25°C...55°C) Derating: 55°C ... 70°C (2.5%/K) Feedback voltage resistance: 35 VDC Protection against overvoltage at the output (OVP): < 35 VDC Max. capacitive load: unlimited Active current limitation: Approx. 48 A Control deviation: < 1 % (change in load, static 10 % ... 90 %) < 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %) Residual ripple: < 20 mVPP Output power: 960 W Peak switching voltages nominal load: < 40 mVPP Maximum no-load power dissipation: 16 W Power loss nominal load max.: 91 W Rise time: < 2 ms (UOUT (10 % ... 90 %)) Connection in parallel: yes, for redundancy and increased capacity Connection in series: yes |
Connection data | Input Connection method: Screw connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 6 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 4 mm² Conductor cross section AWG min.: 22 Conductor cross section AWG max.: 10 Stripping length: 8 mm Screw thread: M3 Tightening torque, min: 0.5 Nm Tightening torque max: 0.6 Nm Output Connection method: Screw connection Conductor cross section, rigid min.: 0.5 mm² Conductor cross section, rigid max.: 16 mm² Conductor cross section flexible min.: 0.5 mm² Conductor cross section flexible max.: 10 mm² Conductor cross section AWG min.: 8 Conductor cross section AWG max.: 6 Stripping length: 10 mm Screw thread: M4 Tightening torque, min: 1.2 Nm Tightening torque max: 1.5 Nm |
Signaling | Types of signaling: LED Operating voltage display: Green LED Signal output Status display: "DC OK" LED green Note on status display: UOUT > 21.5 V: LED lights up |
Electrical properties | Insulation voltage input/output: 4 kV AC (type test) 2 kV AC (routine test) Insulation voltage output / PE: 500 VDC (routine test) Insulation voltage input / PE: 2 kV AC (type test) 2 kV AC (routine test) |
Product properties | Product type: Power supply Product family: TRIO POWER MTBF (IEC 61709, SN 29500): > 930000 h (40°C) Insulation characteristics Protection class: I (with PE connection) Overvoltage category: III Degree of pollution: 2 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/b1eafe341bfc9d4d88302e2149ca86f1/-S204x204-FJPG Width: 139 mm Height: 130 mm Depth: 190 mm Installation dimensions Installation distance right/left: 0 mm / 0 mm Installation distance top/bottom: 50 mm / 50 mm |
Mounting | Assembly instructions: alignable: horizontally 0mm, vertically 50mm Mounting position: horizontal DIN rail NS 35, EN 60715 With protective coating: No |
Material specifications | Housing material: Metal Type of housing: Steel sheet, zinc-plated Side element version: Aluminum |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 70°C (> 55° C derating : 2.5%/K) Ambient temperature (storage/transport): -40°C ... 85°C Climatic class: 3K3 (in acc. with EN 60721) Max. permissible relative humidity (operation): 95 % (at 25°C, non-condensing) Shock: 15g in all directions in acc. with IEC 60068-2-27 Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 2.3g, 90 min. |
Standards and regulations | Rail applications: EN50121-4 Standard â Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN50178/VDE0160 (PELV) Standard â Limitation of mains harmonic currents: EN61000-3-2 Standard - Electrical safety: EN60950-1/VDE0805 (SELV) Standard â Protection against shock currents, basic requirements for protective separation in electrical equipment: EN50178 Standard â Safety extra-low voltage: EN60950-1 (SELV) EN60204 (PELV) Standard - Safe isolation: DINVDE0100-410 |
Approvals | UL approvals: UL/C-UL listed UL508 UL/C-UL Recognized UL60950-1 Conformity/Approvals SIL in accordance with IEC 61508: 0 |
EMC data | Low Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC EMC requirements for noise emission: EN61000-6-3 EN61000-6-4 EMC requirements for noise immunity: EN61000-6-1 EN61000-6-2 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: 8 kV (Test Level 4) Discharge in air: 8 kV (Test Level 3) Comments: Criterion A Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 1 GHz 1 GHz ... 2 GHz 2 GHz ... 3 GHz Test field strength: 10 V/m Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: 4 kV (Test Level 4 - asymmetrical) Output: 4 kV (Test Level 4 - asymmetrical) Signal: 2 kV (Test Level 3 - asymmetrical) Comments: Criterion A Surge voltage load (surge) Standards/regulations: EN61000-4-5 Input: 2 kV (Test Level 3 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output: 1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Comments: Criterion A Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V (Test Level 3) Voltage dips Standards/regulations: EN61000-4-11 Emitted interference Standards/regulations: EN61000-6-3 Radio interference voltage in acc. with EN 55011: EN55011 (EN55022) ClassB, area of application: Industry and residential Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential |
ECLASS | ECLASS-11.0: 27040701 ECLASS-12.0: 27040701 ECLASS-13.0: 27040701 |
ETIM | ETIM 8.0: EC002540 |
UNSPSC | UNSPSC 21.0: 39121000 |