Industrial Automation
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/a40c36bf15325f4886a85bb685dfcd8a/-S204x204-FJPG Width: 24.4 mm Height: 119.8 mm Depth: 71.5 mm |
Interfaces | INTERBUS Connection method: Inline data jumper Transmission speed: 2 Mbps INTERBUSâ Connection method: FSMA plugs Transmission speed: 2 Mbps Transmission physics: FO Inline local bus Connection method: Inline data jumper Transmission speed: 2 Mbps Transmission physics: Copper |
System properties | Module ID code (dec.): 04 ID code (hex): 04 Length code (hex): 0 Length code (dec): 0 Process data channel: 0 bit Input address area: 0 Byte Output address area: 0 Byte Register length: 0 bit Required parameter data: 0 Byte Required configuration data: 0 Byte |
Product properties | Type: modular Product type: I/O component Product family: Inline Scope of delivery: without accessories |
Electrical properties | Potentials: Supply of analog modules (U Supply voltage: 24 VDC (via voltage jumper) Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple) Current draw: max. 57 mA typ. 47 mA Electrical isolation/isolation of the voltage ranges Test voltage: 5 V supply, incoming remote bus, electrically isolated from 5 V supply, outgoing remote bus: 500 VAC, 50 Hz, 1 min. Test voltage: 5 V supply, incoming remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block: 500 VAC, 50 Hz, 1 min. Test voltage: 5 V supply, incoming remote bus, electrically isolated from 24 V main supply, 24 V segment supply: 500 VAC, 50 Hz, 1 min. Test voltage: 5V supply incoming remote bus / functional ground: 500 VAC, 50 Hz, 1 min. Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 5 V supply, incoming remote bus: 500 VAC, 50 Hz, 1 min. Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block: 500 VAC, 50 Hz, 1 min. Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 24 V main supply, 24 V segment supply: 500 VAC, 50 Hz, 1 min. Test voltage: 5V supply outgoing remote bus, electrically isolated from functional ground: 500 VAC, 50 Hz, 1 min. Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply incoming remote bus: 500 VAC, 50 Hz, 1 min. Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply outgoing remote bus: 500 VAC, 50 Hz, 1 min. Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 24 V main supply, 24 V segment supply: 500 VAC, 50 Hz, 1 min. Test voltage: 7.5V communications power, 24V analog supply, 24V bus terminal module supply, 5V communications power, bus branch terminal electrically isolated from functional ground: 500 VAC, 50 Hz, 1 min. Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, incoming remote bus: 500 VAC, 50 Hz, 1 min. Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, outgoing remote bus: 500 VAC, 50 Hz, 1 min. Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block: 500 VAC, 50 Hz, 1 min. Test voltage: 24V main supply, 24V segment supply, electrically isolated from the functional ground: 500 VAC, 50 Hz, 1 min. |
Connection data | Connection method: FSMA plugs Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 55°C Degree of protection: IP20 Air pressure (operation): 80 kPa ... 106 kPa (up to 2000m above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level) Ambient temperature (storage/transport): -25°C ... 85°C Permissible humidity (operation): 75 % (On average, 85 % occasionally) Permissible humidity (storage/transport): 75 % (On average, 85 % occasionally) |
Standards and regulations | Protection class: III (IEC 61140, EN61140, VDE0140-1) |
Mounting | Mounting type: DIN rail mounting |
ECLASS | ECLASS-11.0: 27242608 ECLASS-12.0: 27242608 ECLASS-13.0: 27242608 |
ETIM | ETIM 9.0: EC001604 |
UNSPSC | UNSPSC 21.0: 32151600 |