PHOENIX CONTACT 2882297
PHOENIX CONTACTNot available

MNT-TV-SAT D/WH - Type 3 surge protection device

Socket attachment plug with surge protection for the power supply unit and signal connection for radio and television equipment (cable, terrestrial antenna, satellite system). Cable is provided.
Product Code: 2882297
Partner cod.: 2882297
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesGeneral
Note: Shielding requirements according to DINEN50083-2, Class A
Product propertiesIEC test classification: C2
C3
D1
IEC power supply system: TN
TT
Type: Attachment plug
Product type: Device protection
Product family: MAINTRAB
Number of positions: 2
For country-specific use in: D, A, NL, E, S, FIN, TR
Surge protection fault message: optical
Insulation characteristics
Overvoltage category: II
Pollution degree: 2
IEC test classification: III
T3
EN type: T3
Number of ports: One
Connection dataConnection method: F connector
Grounding plug/socket
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/0019a1ac9c3f1c44ac6534a2f3ab1b3f/-S204x204-FJPG
Width: 63 mm
Height: 107 mm
Depth: 78 mm
Material specificationsFlammability rating according to UL 94: V-0
CTI value of material: 400
600
Insulating material: PA 6
Housing material: PA 6
Protective circuitPower supplies
Direction of action: L/N-PE & Signal Line-Shield-Earth Ground
Nominal voltage UN: 230/400VAC(TN/TT)
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous operating voltage UC (L-N): 275 VAC
Maximum continuous operating voltage UC (L-PE): 360 VAC
Maximum continuous operating voltage UC (N-PE): 360 VAC
Rated load current IL: 16 A (30°C)
Residual current IPE: ≤ 5 µA
Standby power consumption PC: ≤ 1 VA
Reference test voltage UREF: 255 VAC
Combination wave UOC: 6 kV
Voltage protection level Up: ≤ 1.5 kV
TOV behavior at UT (L-N): 460 VAC (5s / withstand mode)
460 VAC (120min / safe failure mode)
TOV behavior at UT (L-PE): 460 VAC (5s / withstand mode)
460 VAC (120min / withstand mode)
1455 VAC (200ms / safe failure mode)
TOV behavior at UT (N-PE): 1200 VAC (200ms / safe failure mode)
Response time tA (L-N): ≤ 25 ns
Response time tA (L-PE): ≤ 100 ns
Response time tA (N-PE): ≤ 100 ns
Max. required back-up fuse: 16 A (gG / B / C)
Short-circuit current rating ISCCR: 1.5 kA AC
Information technology
Maximum continuous voltage UC: 24 VDC
Rated current: 1.5 A (25°C)
Operating effective current IC at UC: ≤ 1 µA
Standby power consumption PC: ≤ 1 VA
Residual current IPE: ≤ 1 µA
Insulation resistance Riso: ≥ 70 MΩ
Nominal discharge current In (8/20) µs (line-ground): 2.5 kA
Nominal discharge current In (8/20) µs (line-shield): 2.5 kA
Nominal discharge current In (8/20)µs (shield-ground): 5 kA
Total discharge current Itotal (8/20)µs: 5 kA
Nominal pulse current Ian (10/1000) µs (line-shield): 120 A
Nominal pulse current Ian (10/1000) µs (shield-ground): 200 A
Output voltage limitation at 1 kV/µs (line-shield) spike: ≤ 700 V
Output voltage limitation at 1kV/µs (shield-ground) spike: ≤ 1 kV
Output voltage limitation at 1 kV/µs (line-shield) static: ≤ 700 V
Output voltage limitation at 1kV/µs(shield-ground) static: ≤ 1 kV
Residual voltage at In (conductor-shield): ≤ 40 V
Residual voltage at In (shield-ground): ≤ 50 V
Voltage protection level Up (line-shield): ≤ 700 V (C2 - 2 kA)
Voltage protection level Up (shield-ground): ≤ 1.2 kV (C2 - 5 kA)
Response time tA (line-shield): ≤ 100 ns
Response time tA (shield-ground): ≤ 100 ns
Input attenuation aE, asym.: typ. 0.3 dB (≤ 2.4 GHz /75 Ω)
Cut-off frequency fg (3dB), asym. (shield) in 75Ω system: typ. 2.5 GHz
Frequency range: 0 Hz ... 2400 MHz
Capacity asymmetrical (shield): typ. 10 pF
Alternating current carrying capacity (line-shield): 5A - 1s
Alternating current carrying capacity (shield-ground): 10A - 1s
Pulse reset time (line-shield): ≤ 4s
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (Child-proofing)
Ambient temperature (operation): -25°C ... 75°C
Ambient temperature (storage/transport): -25°C ... 75°C
Altitude: ≤ 2000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Standards and regulationsStandards/specifications: IEC 61643-11
EN61643-11
EN61643-21
IEC 61643-21
EN50083
Note: 2011
2019
A2:2013
A2:2012
CLASS-A
MountingMounting type: Plugging into the mains socket
Technical Specs
ECLASSECLASS-11.0: 27130810
ECLASS-13.0: 27171603
ETIMETIM 9.0: EC001625
UNSPSCUNSPSC 21.0: 39121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Flyer_00001.pdf

Flyer_00002.pdf

Manufacturer_declaration_01357.pdf

Manufacturer_declaration_02315.pdf

Manufacturer_declaration_15396.pdf

Package_slip_00340.pdf

Technical_drawing_39143.pdf