EMD-FL-PF-400 - Monitoring relay

Monitoring relay for load monitoring (cos ϕ = 0,1…1) in 1- and 3-phase networks, underload, overload, window, error memory, wide range power supply unit, 2 changeover contacts
Product Code: 2885809
Partner cod.: 2885809
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Load monitoring relay
Operating mode: 100% operating factor
Mechanical service life: approx. 2x 107 cycles
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics​
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesService life electrical: 2x 105 cycles at ohmic load, 1000 VA
Mains type: 1 and 3-phase
Rated insulation voltage: 300 V
Rated surge voltage: 4 kV
Supply
Supply voltage range: 24 VAC ... 240 VAC -15%...+10%
24 VDC ... 240 VDC (-20%...+25%)
Type of supply voltage: AC/DC
Nominal power consumption: 4.5 VA (1.5W)
Input dataInput name: Measuring input
Measured value: AC sine (10 ... 100 Hz)
Nominal input voltage UN: 3 N ~ 415/240 V
Input voltage range: 40 VAC ... 415 VAC (1(N) ~, single-phase load)
40 VAC ... 415 VAC (3(N) ~, 3-phase load)
Maximum input voltage: 3 N ~ 500/289 V
Input current range: 0.5 A ... 10 A (Connection terminal blocks: L1i and L1k)
Overload capacity: 12 A permanent
Input resistance of voltage input: ≥ 1 MΩ
Input resistance current input: 5 mΩ
Min. switching threshold cos φ: 0.1 ... 0.99
Max. switching threshold cos φ: 0.2 ... 1
Frequency range: 48 Hz ... 400 Hz
Maximum temperature coefficient: ≤ 0.1 %/K
Setting range for response delay: 0.1 s ... 40 s
Setting range for starting delay: 1 s ... 100 s
Function: Underload
Overload
Window
Error memory
Basic accuracy: ± 5 % (At cos φ = 0.8)
Setting accuracy: ≤ 5 % (At cos φ = 0.8)
Repeat accuracy: ± 1.8 %
Recovery time: 500 ms
Output dataSwitching
Contact switching type: 2 floating changeover contacts
Maximum switching voltage: 250 VAC (in acc. with IEC 60664-1)
Interrupting rating (ohmic load) max.: 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)
1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)
Output fuse: 5 A (fast-blow)
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Conductor cross section rigid: 0.5 mm² ... 2.5 mm²
Conductor cross section flexible: 0.25 mm² ... 2.5 mm²
Conductor cross section AWG: 20 ... 14
DimensionsWidth: 22.5 mm
Height: 90 mm
Depth: 113 mm
Material specificationsHousing insulation material: Polyamide PA, self-extinguishing
Environmental and real-life conditionsAmbient conditions
Degree of protection (Housing): IP40 (Housing)
Degree of protection (Connection terminal blocks): IP20 (Connection terminal blocks)
Ambient temperature (operation): -25°C ... 55°C
-25°C ... 40°C (corresponds to UL508)
Ambient temperature (storage/transport): -25°C ... 70°C
Climatic class: 3K3 (in acc. with EN 60721)
Permissible humidity (operation): 15 % ... 85 %
ApprovalsCE
Certificate: CE-compliant
UL, USA/Canada
Identification: UL/C-UL Listed UL 508
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Noise immunity: EN 61000-6-2
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Standards and regulationsStandards/regulations: EN50178
MountingMounting type: DIN rail mounting
Assembly instructions: on standard DIN rail NS 35 in accordance with EN 60715
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371016
ECLASS-13.0: 27371016
ECLASS-12.0: 27371016
ETIMETIM 9.0: EC002055
UNSPSCUNSPSC 21.0: 39121100
Description
Monitoring relay for load monitoring (cos ? = 0,1 ... 1) in 1- and 3-phase networks, underload, overload, window, error memory, wide-range power supply unit, 2 PDTs
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Data_sheet_03701.pdf

Manufacturer_declaration_01582.pdf

Manufacturer_declaration_04697.pdf

Package_slip_01003.pdf

Technical_drawing_39165.pdf