Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2900363
PHOENIX CONTACT 2900363
PHOENIX CONTACTNot available

PLC-OPT- 24DC/TTL - Solid-state relay module

PLC-INTERFACE for TTL signal, consisting of PLC-O.../TTL basic terminal block with push-in connection and integrated solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24 V DC, output: TTL (5 V DC)
Product Code: 2900363
Partner cod.: 2900363
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Solid-state relay module
Product family: PLC-INTERFACE
Application: TTL signal at output
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.08 W
Test voltage (Input/output): 2.5 kVrms (50Hz, 1min., input/output)
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VDC
Rated surge voltage: 4 kV
Input dataRated actuating voltage UC: 24 VDC
Voltage range with reference to UC: 0.8 ... 1.2
Rated actuating current IC: 3.4 mA
Switching threshold "0" signal in reference to UN: < 0.4
Switching threshold "1" signal in reference to UN: > 0.8
Typical input current at UN: 3.4 mA
Typical response time: 35 µs
Typical turn-off time: 35 µs
Operating voltage display: Yellow LED
Protective circuit: Reverse polarity protection; Parallel polarity protection diode
Surge protection
Surge voltage protection: > 33 V
Transmission frequency: 1 kHz
Output dataDesignation: Output data
Contact switching type: 1 N/O contact
Design of digital output: electronic
Contact connection type: Signal contact
Rated control circuit supply voltage US: 5 VDC
Voltage range with reference to US: 0.9 ... 1.2
Output voltage range: 4.5 VDC ... 6 VDC
Limiting continuous current: 50 mA (a TTL load (Fan out = 1))
Fan out: 1
Surge voltage protection: > 8 V
Voltage drop at max. limiting continuous current: < 80 mV
Output circuit: 3-conductor, ground-referenced
Protective circuit: Reverse polarity protection; Parallel polarity protection diode
Surge protection
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 86 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCorrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371604
ECLASS-12.0: 27371604
ECLASS-13.0: 27371604
ETIMETIM 9.0: EC001504
UNSPSCUNSPSC 21.0: 39122300
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01883.pdf

Manufacturer_declaration_01205.pdf

Manufacturer_declaration_01848.pdf

Manufacturer_declaration_03448.pdf

Manufacturer_declaration_03449.pdf

Manufacturer_declaration_03605.pdf

Manufacturer_declaration_15539.pdf

Package_slip_01741.pdf

Product_information_00033.pdf

Product_information_00842.pdf

Technical_drawing_39382.pdf