PLC-BPT-230UC/ 1/SEN/SO46 - Relay base


Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area |
Product properties | Product type: Relay socket Product family: PLC-INTERFACE Application: Filter to prevent interference Operating mode: 100% operating factor Compatible components: Miniature relay, REL-MR-60DC/21AU, REL-MR-60DC/21; miniature optocoupler, OPT-60DC/48DC/100, OPT-60DC/24DC/2, OPT-60DC/230AC/1 |
Electrical properties | Protective circuit: Bridge rectifier; Bridge rectifier RCZ filter; RCZ filter |
Input data | Nominal input voltage UN: 230 VÃAC Relay assembly Nominal input voltage UN: 230 VÃAC Input voltage range in reference to UN: 0.78 ... 1.14 Typical input current at UN: 8.8 mA (50ÃHz) 10 mA (60ÃHz) Typical response time: 7 ms Typical release time: 20 ms Typical release voltage: 80 VÃAC Operating voltage display: Yellow LED Protective circuit: Bridge rectifier; Bridge rectifier Filter; Filter Optocoupler assembly Nominal input voltage UN: 230 VÃAC Input voltage range in reference to UN: 0.8 ... 1.1 Typical input current at UN: 8.8 mA 10 mA Switching threshold "0" signal in reference to UN: ââ°¤ 0.4 Typical response time: 6 ms Typical release time: 10 ms Operating voltage display: Yellow LED Protective circuit: Bridge rectifier; Bridge rectifier Filter; Filter |
Output data | Compatible components: Miniature relay, REL-MR-60DC/21AU, REL-MR-60DC/21; miniature optocoupler, OPT-60DC/48DC/100, OPT-60DC/24DC/2, OPT-60DC/230AC/1 Maximum switching voltage: 48 VÃDC 30 VÃDC 253 VÃAC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) Minimum switching voltage: 3 VÃDC 24 VÃAC Limiting continuous current: 100 mA 3 A 0.75 A Voltage drop at max. limiting continuous current: < 1 VÃDC < 200 mV < 1 VÃAC Output circuit: 2-conductor, floating Protective circuit: Reverse polarity protection Surge protection Reverse polarity protection Surge protection RCV circuit Maximum inrush current: 15 A (10 ms) 30 A (10 ms) Leakage current: < 1 mA Phase angle cos phi min: 0.5 Max. load value: 4.5 A2s |
Connection data | Connection method: Push-in connection Stripping length: 10 mm Conductor cross section rigid: 0.14 mm² ... 2.5 mm² Conductor cross section flexible: 0.14 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² (Single ferrule) 2x 0.5 mm² ... 1 mm² (TWIN ferrule) Conductor cross section AWG: 26 ... 14 |
Signaling | Status display: LED |
Dimensions | Width: 6.2 mm Height: 80 mm Depth: 94 mm |
Material specifications | Flammability rating according to UL 94: V0 (Housing) |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -40°C ... 55°C Ambient temperature (storage/transport): -40°C ... 85°C |
Approvals | CE Certificate: CE-compliant UKCA Certificate: UKCA-compliant Shipbuilding approval Certificate: TAE0000196 Corrosive gas test Identification: ISA-S71.04. G3 Harsh Group ENÃ60068-2-60 DNV GL data Temperature: D Humidity: A Vibration: B/C EMC: B Enclosure: Required protection according to the Rules shall be provided upon installation on board |
EMC data | Low Voltage Directive: Conformance with Low Voltage Directive Electromagnetic compatibility: Conformance with EMC directive |
Mounting | Mounting type: DIN rail mounting Assembly instructions: in rows with zero spacing Mounting position: any |