Industrial Automation
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area |
Product properties | Product type: Frequency value transformer Product family: MINI Analog Pro No. of channels: 1 Type: Signal conditioner Configuration: DIP switches Software App Insulation characteristics Overvoltage category: II Pollution degree: 2 |
System properties | Functionality Configuration: DIP switches Software App |
Electrical properties | No. of channels: 1 Electrical isolation between input and output: yes Step response (0â99%): 120 ms (15 Hz sample rate) 35 ms (60Hz sample rate) 15 ms (240Hz sample rate, can only be set via software) 130 ms (15 Hz sample rate) 40 ms (60Hz sample rate) 20 ms (240Hz sample rate, can only be set via software) Maximum temperature coefficient: < 0.01 %/K Temperature coefficient, typical: 0.01 %/K Electrical isolation Input/output/power supply Rated insulation voltage: 300 Vrms Test voltage: 3 kV AC (50Hz, 60s) Insulation: Reinforced insulation according to IEC/EN61010-1 Supply Nominal supply voltage: 24 VDC Supply voltage range: 9.6 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715) Typical current consumption: 27 mA (12VDC) 13.5 mA (24VDC) Power consumption: ⤠350 mW (9.6VDC) |
Input data | Signal: Voltage/current Number of inputs: 1 Configurable/programmable: Yes Voltage input signal: 0 V ... 10 V (via DIP switch) 2 V ... 10 V (via DIP switch) 0 V ... 5 V (via DIP switch) 1 V ... 5 V (via DIP switch) 10 V ... 0 V (via DIP switch) 10 V ... 2 V (via DIP switch) 5 V ... 0 V (via DIP switch) 5 V ... 1 V (via DIP switch) 0 V ... 12 V (can be set via software) Max. voltage input signal: 12 V Current input signal: 0 mA ... 20 mA (via DIP switch) 4 mA ... 20 mA (via DIP switch) 0 mA ... 10 mA (via DIP switch) 2 mA ... 10 mA (via DIP switch) 20 mA ... 0 mA (via DIP switch) 20 mA ... 4 mA (via DIP switch) 10 mA ... 0 mA (via DIP switch) 10 mA ... 2 mA (via DIP switch) 0 mA ... 24 mA (can be set via software) Max. current input signal: 24 mA Input resistance of voltage input: > 120 ké Input resistance current input: ~ 50 é (+0.7V for test diode) |
Output data | Frequency: Frequency/transistor Frequency output: 0 Hz ... 10 kHz (via DIP switch) 0 Hz ... 5 kHz (via DIP switch) 0 Hz ... 2.5 kHz (via DIP switch) 0 Hz ... 1 kHz (via DIP switch) 0 Hz ... 500 Hz (via DIP switch) 0 Hz ... 250 Hz (via DIP switch) 0 Hz ... 100 Hz (via DIP switch) 0 Hz ... 50 Hz (via DIP switch) 0 Hz ... 10.5 kHz (can be set via software) Load min.: 4 mA ⤠(UL / RL) ⤠100 mA 12 mA ⤠(UL / RL) ⤠100 mA Maximum transmission error: ⤠0.1 % (> 7 kHz ⤠0.2%) < 0.2 % (PWM frequency ï£ 500Hz) < 0.5 % (500Hz < PWM frequency ï£ 2000Hz) < 1 % (2000Hz < PWM frequency ï£ 4000Hz) < 2 % (4000Hz < PWM frequency ï£ 8000Hz) < 3 % (8000Hz < PWM frequency ï£ 16000Hz) Output signal PWM: 15.6 kHz (10bits, via DIP switch) 1.9 kHz (10bits, via DIP switch) 3.9 kHz (12bits, via DIP switch) 488 Hz (12bits, via DIP switch) 977 Hz (14bits, via DIP switch) 122 Hz (14bits, via DIP switch) 244 Hz (16bits, via DIP switch) 31 Hz (16bits, via DIP switch) 31 Hz ... 15.6 kHz (can be set via software) Load current maximum: 100 mA Maximum switching voltage: 30 VDC Overrange/underrange: Can be set (via software) Switching: Transistor Number of outputs: 1 Contact switching type: 1 N/O contact Minimum switching voltage: 1 VDC Maximum switching voltage: 30 VDC Min. switching current: 100 µA Max. switching current: 100 mA (30VDC) Signal Number of outputs: 1 |
Connection data | Connection method: Screw connection Stripping length: 10 mm Screw thread: M3 Conductor cross section rigid: 0.2 mm² ... 1.5 mm² (with ferrule) 0.14 mm² ... 2.5 mm² (without ferrule) Conductor cross section flexible: 0.14 mm² ... 2.5 mm² Conductor cross section AWG: 24 ... 12 (flexible) Tightening torque: 0.5 Nm ... 0.6 Nm |
Ex data | Ex installation (EPL): Gc Div.2 |
Interfaces | Data: IFS interface Connection method: Micro USB type B |
Signaling | Error indication: Red LED |
Dimensions | Width: 6.2 mm Height: 109.81 mm Depth: 119.2 mm |
Material specifications | Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2 Housing material: PBT |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 (not assessed by UL) Ambient temperature (operation): -40°C ... 70°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠2000 m Permissible humidity (operation): 5 % ... 95 % (non-condensing) |
Approvals | CE Certificate: CE-compliant ATEX Identification: ï II 3 G Ex ec IIC T4 Gc Certificate: BVS 19 ATEX E 083 X UKCAEx(UKEX) Identification: ï II 3 G Ex ec IIC T4 Gc Certificate: PxCIF21UKEX2905026X IECEx Identification: Ex ec IIC T4 Gc Certificate: IECEx BVS 19.0072X CCC/China-Ex Identification: Ex nA IIC T4 Gc Certificate: NEPSIGYJ20.1318X UL, USA/Canada Identification: UL508 Listed Class I, Div. 2, Groups A, B, C, D T6 Class I, Zone 2, Group IIC T6 Shipbuilding approval Certificate: DNV GL TAA000021E Rev. 1 EACEx Identification: ï 2Ex ec IIC T4 Gc Certificate: BY/112 02.01 TP012 103.01 00081 DNV GL data Temperature: B Humidity: B Vibration: A EMC: A Enclosure: Required protection according to the Rules shall be provided upon installation on board |
EMC data | Noise immunity: EN 61000-6-2 Note: When being exposed to interference, there may be minimal deviations. Electromagnetic compatibility: Conformance with EMC directive Noise emission: EN 61000-6-4 |
Mounting | Mounting type: DIN rail mounting Assembly instructions: The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35mm EN60715 DIN rail. Mounting position: any |
ECLASS | ECLASS-11.0: 27210128 ECLASS-12.0: 27210128 ECLASS-13.0: 27210128 |
ETIM | ETIM 9.0: EC002918 |
UNSPSC | UNSPSC 21.0: 39121000 |