Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2902829
PHOENIX CONTACTNot available

MINI MCR-SL-UI-I-LP-NC - Signal conditioner

2-way loop-powered isolating amplifier (supplied on the output side), can be configured via DIP switches, with screw connection technology and standard configuration.
Product Code: 2902829
Partner cod.: 2902829
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Signal conditioner
Product family: MINI Analog
No. of channels: 1
Configuration: DIP switches
Insulation characteristics
Overvoltage category: II
Pollution degree: 2
Electrical propertiesAlignment span: ± 2 %
Alignment zero: ± 2 %
No. of channels: 1
Electrical isolation: 2-way isolation
Electrical isolation between input and output: yes
Limit frequency (3 dB): approx. 30 Hz
Maximum power dissipation for nominal condition: 19 mW
Step response (10-90%): approx. 16 ms
Maximum temperature coefficient: 0.01 %/K
Temperature coefficient, typical: 0.005 %/K
Maximum transmission error: < 0.1 % (of final value)
< 0.2 % (Without adjustment)
Electrical isolation Input/output
Rated insulation voltage: 50 V AC/DC
Test voltage: 1.5 kV AC (50Hz, 60s)
Insulation: Basic insulation in accordance with IEC/EN61010
Supply
Supply voltage range: loop-powered, no external supply necessary
Power consumption: 28 mW (without signal)
Input dataSignal: Voltage/current
Number of inputs: 1
Voltage input signal: 0 mV ... 1000 mV
0 mV ... 750 mV
0 mV ... 500 mV
0 mV ... 300 mV
0 mV ... 250 mV
0 mV ... 200 mV
0 mV ... 150 mV
0 mV ... 125 mV
0 mV ... 120 mV
0 mV ... 100 mV
0 mV ... 75 mV
0 mV ... 60 mV
0 mV ... 50 mV
0 V ... 10 V
0 V ... 7.5 V
0 V ... 5 V
0 V ... 3 V
0 V ... 2.5 V
0 V ... 2 V
0 V ... 1.5 V
0 V ... 1.25 V
0 V ... 1.2 V
0 V ... 30 V
0 V ... 25 V
0 V ... 20 V
0 V ... 12.5 V
0 V ... 12 V
0 V ... 15 V
-1000 mV ... 1000 mV
-750 mV ... 750 mV
-500 mV ... 500 mV
-300 mV ... 300 mV
-250 mV ... 250 mV
-200 mV ... 200 mV
-125 mV ... 125 mV
-120 mV ... 120 mV
-150 mV ... 150 mV
-100 mV ... 100 mV
-75 mV ... 75 mV
-60 mV ... 60 mV
-50 mV ... 50 mV
-10 V ... 10 V
-7.5 V ... 7.5 V
-5 V ... 5 V
-3 V ... 3 V
-2.5 V ... 2.5 V
-2 V ... 2 V
-1.25 V ... 1.25 V
-1.2 V ... 1.2 V
-1.5 V ... 1.5 V
-30 V ... 30 V
-25 V ... 25 V
-20 V ... 20 V
-12.5 V ... 12.5 V
-12 V ... 12 V
-15 V ... 15 V
200 mV ... 1000 mV
150 mV ... 750 mV
100 mV ... 500 mV
60 mV ... 300 mV
50 mV ... 250 mV
40 mV ... 200 mV
25 mV ... 125 mV
24 mV ... 120 mV
30 mV ... 150 mV
20 mV ... 100 mV
15 mV ... 75 mV
12 mV ... 60 mV
10 mV ... 50 mV
2 V ... 10 V (additional areas can be configured, see table)
1.5 V ... 7.5 V
1 V ... 5 V
0.6 V ... 3 V
0.5 V ... 2.5 V
0.4 V ... 2 V
0.25 V ... 1.25 V
0.24 V ... 1.2 V
0.3 V ... 1.5 V
6 V ... 30 V
5 V ... 25 V
4 V ... 20 V
2.5 V ... 12.5 V
2.4 V ... 12 V
3 V ... 15 V
Max. voltage input signal: < 40 V
Current input signal: 0 mA ... 40 mA
0 mA ... 30 mA
0 mA ... 20 mA
0 mA ... 12 mA
0 mA ... 10 mA
0 mA ... 8 mA
0 mA ... 7.5 mA
0 mA ... 5 mA
0 mA ... 6 mA
0 mA ... 4 mA
0 mA ... 3 mA
0 mA ... 2.5 mA
0 mA ... 2 mA
-40 mA ... 40 mA
-30 mA ... 30 mA
-20 mA ... 20 mA
-12 mA ... 12 mA
-10 mA ... 10 mA
-8 mA ... 8 mA
-7.5 mA ... 7.5 mA
-5 mA ... 5 mA
-6 mA ... 6 mA
-4 mA ... 4 mA
-3 mA ... 3 mA
-2.5 mA ... 2.5 mA
-2 mA ... 2 mA
8 mA ... 40 mA
6 mA ... 30 mA
4 mA ... 20 mA
2.4 mA ... 12 mA
2 mA ... 10 mA
1.6 mA ... 8 mA
1.5 mA ... 7.5 mA
1 mA ... 5 mA
1.2 mA ... 6 mA
0.8 mA ... 4 mA
0.6 mA ... 3 mA
0.5 mA ... 2.5 mA
0.4 mA ... 2 mA
Max. current input signal: < 50 mA (Dielectric strength up to 30 V)
Input resistance of voltage input: 100 kΩ (≤1V)
1 MΩ (≥ 1 V)
Input resistance current input: ≤ 50 Ω
Output dataSignal
Number of outputs: 1
Configurable/programmable: Yes, preconfigured
Current output signal: 4 mA ... 20 mA
Max. current output signal: 35 mA (output limit)
Load/output load current output: < 1000 Ω ((UB - 8V) / 22mA)
Ripple: < 20 mVPP (at 500 Ω)
Connection dataConnection method: Screw connection
Stripping length: 12 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 26 ... 12
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/8450693c9d67004aa7841c306225c8da/-S204x204-FJPG
Width: 6.2 mm
Height: 93.1 mm
Depth: 101.2 mm
Material specificationsFire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
Housing material: PBT
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA/Canada
Identification: UL508 Listed
Class I, Div. 2, Groups A, B, C, D T5
Class I, Zone 2, Group IIC
Shipbuilding approval
Certificate: DNV GL TAA00002R0
DNV GL data
Temperature: B
Humidity: B
Vibration: B
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Comments: Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Typical deviation from the measuring range final value: 0.5 %
Electromagnetic HF field​
Comments: Criterion A
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Typical deviation from the measuring range final value: 2 %
Fast transients (burst)​
Comments: Criterion B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Comments: Criterion B
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Typical deviation from the measuring range final value: 0.5 %
Conducted interference​
Comments: Criterion A
Standards and regulationsElectrical isolation: 2-way isolation
MountingMounting type: DIN rail mounting
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01435.pdf

Data_sheet_03775.pdf

Manual_00026.pdf

Manufacturer_declaration_02214.pdf

Manufacturer_declaration_04758.pdf

Manufacturer_declaration_15733.pdf

Package_slip_01673.pdf

Product_information_00033.pdf

Technical_drawing_39657.pdf