PHOENIX CONTACT 2903527
PHOENIX CONTACTAvailable

EMD-BL-PH-480 - Monitoring relay

Monitoring relay for monitoring the phase sequence and asymmetry of 3-phase voltages at 208 ... 480 V AC / 120 ... 277 V AC, configurable asymmetry, 1 changeover contact, with screw connection
Product Code: 2903527
Partner cod.: 2903527
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Phase monitoring relay
Operating mode: 100% operating factor
Mechanical service life: 15x 106 cycles
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics​
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesService life electrical: 1x 105 cycles
Mains type: 3-phase
Rated insulation voltage: 519 V (Supply circuit)
250 V (Output circuit)
Rated surge voltage: 4 kV
Supply
Supply voltage: ±10% (= measuring voltage)
Supply voltage range: ±10% (= measuring voltage)
Nominal power consumption: 10 VA ((1W) at 400V/50Hz)
16 VA ((1.5W) at 480V/60Hz)
Input dataInput name: Measuring input
Measured value: AC sine (48 Hz ... 63 Hz)
Nominal input voltage UN: 480 V (3~ 208 ... 480 V/120 ... 277 V)
Frequency range: 48 Hz ... 63 Hz
Setting range for response delay: 0.1 s ... 10 s
Min setting range of the voltage threshold value: 187 VAC
Max. setting range of the voltage threshold value: 519 VAC
Function: Phase sequence
Phase failure
Asymmetry
Basic accuracy: ≤ 5 % (of scale end value)
Setting accuracy: ± 5 % (of scale end value)
Repeat accuracy: ≤ 2 %
Asymmetry: 5% ... 25% / OFF
Recovery time: > 500 ms
Output dataSwitching
Contact switching type: 1 floating changeover contact
Maximum switching voltage: 250 VAC (in acc. with IEC 60664-1)
Interrupting rating (ohmic load) max.: 1250 VA (5A / 250VAC)
Output fuse: 5 A (fast-blow)
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Conductor cross section rigid: 0.5 mm² ... 2.5 mm²
Conductor cross section flexible: 0.5 mm² ... 2.5 mm²
Conductor cross section AWG: 20 ... 14
Tightening torque: 1 Nm ... 1 Nm
SignalingStatus display: Yellow LED
Operating voltage display: Green LED
Error indication: Red LED
DimensionsWidth: 17.5 mm
Height: 89.5 mm
Depth: 65.5 mm
Material specificationsHousing insulation material: Polyamide PA 6.6, self-extinguishing
Environmental and real-life conditionsAmbient conditions
Degree of protection (Housing): IP40 (Housing)
Degree of protection (Connection terminal blocks): IP20 (Connection terminal blocks)
Ambient temperature (operation): -25°C ... 55°C
Ambient temperature (storage/transport): -25°C ... 70°C
Climatic class: 3K3 (in acc. with EN 60721)
Permissible humidity (operation): 15 % ... 85 %
ApprovalsCE
Certificate: CE-compliant
UL, USA/Canada
Identification: UL/C-UL Listed UL 508
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Noise immunity: EN 61000-6-2
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-3
Standards and regulationsStandards/regulations: DINEN60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: on standard DIN rail NS 35 in accordance with EN 60715
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371803
ECLASS-12.0: 27371803
ECLASS-13.0: 27371803
ETIMETIM 9.0: EC001441
UNSPSCUNSPSC 21.0: 39121100
Description
Monitoring relay for monitoring the phase sequence and asymmetry of 3-phase voltages at 208 ... 480 V AC/120 ... 277 V AC, configurable asymmetry, 1 PDT, with screw connection
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Data_sheet_03818.pdf

Manufacturer_declaration_01960.pdf

Manufacturer_declaration_04792.pdf

Package_slip_00996.pdf

Product_information_00033.pdf

Product_information_00623.pdf

Technical_drawing_39811.pdf