Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2904508
PHOENIX CONTACTNot available

MINI MCR-2-FM-RC-PT - Monitoring block

Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the FM system and for monitoring the supply voltages. Error message via N/C contact. Push-in connection technology, standard configuration
Product Code: 2904508
Partner cod.: 2904508
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Evaluation unit
Product family: MINI Analog Pro
Configuration: DIP switches
Insulation characteristics: GBStandard
Overvoltage category: II
Pollution degree: 2
System propertiesFunctionality
Configuration: DIP switches
Electrical propertiesRated insulation voltage: 50 V AC/DC (effective)
Electrical isolation: Basic insulation in accordance with EN 61010
Test voltage (Input/output): 1.5 kV AC (50Hz, 60s)
Maximum temperature coefficient: < 0.01 %/K
Electrical isolation​
Electrical isolation: Input, power supply and output to the switching output
Supply
Supply voltage range: 9.6 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715)
Max. current consumption: < 16 mA (24VDC)
Power consumption: < 410 mW (24VDC)
Input dataSignal: Voltage
Description of the input: Voltage input for redundancy monitoring
Number of inputs: 1
Voltage input signal: 9.9 VDC ... 30 VDC
Output dataSwitching: Relay
Maximum switching voltage: 30 VDC
Max. switching current: 50 mA
Signal: Voltage
Number of outputs: 1
Voltage output signal: 9.6 VDC ... 29.7 VDC
Max. current output signal: 3.2 A
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.2 mm² ... 2.5 mm² (with ferrule)
0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12 (flexible)
Ex dataEx installation (EPL): Gc
Div.2
SignalingStatus display: Green LED (supply voltage)
Yellow LED (switching output)
Error indication: Red LED
DimensionsWidth: 6.2 mm
Height: 109.81 mm
Depth: 119.2 mm
Material specificationsFire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
Housing material: PBT
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (not assessed by UL)
Ambient temperature (operation): -40°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
ATEX
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: BVS 20 ATEX E 014X
UKCAEx(UKEX)
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: PxCIF21UKEX2902004X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECEx BVS 20.0010X
CCC/China-Ex
Identification: Ex nA IIC T4 Gc
Certificate: NEPSIGYJ20.1320X
UL, USA/Canada
Identification: UL508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Shipbuilding approval
Certificate: DNV GL TAA00002UA
EACEx
Identification:  2Ex ec IIC T4 Gc
Certificate: BY/112 02.01 TP012 103.01 00079
DNV GL data
Temperature: B
Humidity: B
Vibration: A
EMC: A
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Comments: Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Surge current load (surge)
Standards/regulations: EN61000-4-5
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Standards and regulationsElectrical isolation: Basic insulation in accordance with EN 61010
GBStandard
Standards/regulations: GB3836.1
GB3836.8
MountingMounting type: DIN rail mounting
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371392
ECLASS-12.0: 27371392
ECLASS-13.0: 27371392
ETIMETIM 9.0: EC002498
UNSPSCUNSPSC 21.0: 39121100
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00128.pdf

Approvals_00172.pdf

Approvals_00173.pdf

Approvals_01457.pdf

Approvals_01462.pdf

Approvals_01468.pdf

Data_sheet_03828.pdf

Manual_00026.pdf

Manufacturer_declaration_00754.pdf

Manufacturer_declaration_01719.pdf

Manufacturer_declaration_15936.pdf

Manufacturer_declaration_17788.pdf

Package_slip_01614.pdf

Product_information_00033.pdf

Product_information_00639.pdf

Technical_drawing_39964.pdf