Industrial Automation
FLT 100 N/PE CTRL-3.0 - Type 1+2 combined lightning current and surge arrester
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Notes | General Note: 100 % lightning impulse sparkover voltage (1.2/50) µs ⤠1.5 kV |
Product properties | IEC test classification: I T1 EN type: T1 IEC power supply system: TT TN-S Type: DIN rail module, one-piece Product type: Combination type Number of positions: 1 Surge protection fault message: none Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Nominal frequency fN: 50 Hz (60Hz) |
Connection data | Connection method: Screw terminal blocks Screw thread: M6 Tightening torque: 8 Nm Stripping length: 19 mm Conductor cross section flexible: 35 mm² Conductor cross section rigid: 10 mm² ... 50 mm² Conductor cross section AWG: 6 ... 1 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3fc3e8408653964ab5978ac207232c2e/-S204x204-FJPG Width: 35.8 mm Height: 89.8 mm Depth: 65.8 mm Horizontal pitch: 2 Div. |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PBT Material group: I Housing material: PBT |
Mechanical properties | Mechanical data Open side panel: No |
Protective circuit | Mode of protection: N-PE Direction of action: N-PE Nominal voltage UN: 230/400VAC (TN - only N-PE) 230/400VAC (TT - only N-PE) Nominal frequency fN: 50 Hz (60Hz) Maximum continuous voltage UC: 260 VAC Rated load current IL: 80 A Residual current IPE: ⤠0.1 mA Standby power consumption PC: ⤠26 mVA Nominal discharge current In (8/20) µs: 100 kA Impulse discharge current (10/350)µs, charge: 50 As Impulse discharge current (10/350)µs, specific energy: 2500 kJ/é Impulse discharge current (10/350)µs, peak value limp: 100 kA Follow current interrupt rating Ifi: 100 A (260 V AC) Voltage protection level Up: ⤠3 kV Front of wave sparkover voltage at 6 kV (1.2/50) µs: ⤠3 kV TOV behavior at UT: 1200 VAC (200ms / withstand mode) Response time tA: ⤠100 ns |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 (only when all terminal points are used) Ambient temperature (operation): -40°C ... 85°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠2000 m (amsl) Permissible humidity (operation): 5 % ... 95 % |
Standards and regulations | Standards/specifications: IEC 61643-11 EN61643-11 Note: 2011 2012 |
Mounting | Mounting type: DIN rail: 35 mm |
ECLASS | ECLASS-11.0: 27130802 ECLASS-13.0: 27171201 |
ETIM | ETIM 9.0: EC000381 |
UNSPSC | UNSPSC 21.0: 39121600 |