Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2905908
PHOENIX CONTACT 2905908
PHOENIX CONTACTNot available

TRIO-UPS-2G/1AC/1AC/120V/750VA - Uninterruptible power supply

1AC/1AC/750VA uninterruptible power supply with integrated energy storage, lead AGM, VRLA technology, 24DC, 4Ah for 120VAC applications.
Product Code: 2905908
Partner cod.: 2905908
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Input dataAC operation
Input voltage: 120 VAC
Input voltage range: 96 VAC ... 138 VAC
Voltage type of supply voltage: AC
Frequency range (fN): 45 Hz ... 55 Hz
55 Hz ... 65 Hz
Current consumption: 6 A (max.)
Power factor (cos phi): 0.8
Input fuse: 10 A 400 V gRL
Permissible backup fuse: B10 B16 Listed breaker
Digital Control (configurable)
Designation: Remote
Low signal: Connection to SGnd with < 2.7 kΩ
High signal: Open (> 35 kΩ between Remote and SGnd)
Digital Control Low-Active (configurable)
Battery-operated start 120 VAC low signal: Connection to SGnd with < 2.7 kΩ
Battery-operated start 120 VAC high signal: Open (> 200 kΩ between Bat.-Start and SGnd)
Output dataClassification according to IEC 62040-3: VFD-SS-311
Efficiency: > 95 % (100%load, with charged energy storage)
~ 81 % (100%load)
Nominal output voltage: 120 VAC
Form of output voltage: Pure sine
Nominal output current (IN): 6 A
Bridging time: 60 s
UPS connection in parallel: no
UPS connection in series: no
Apparent power: 750 VA
Nominal power: 600 W (Real power)
Crest factor: 2.8
Switch-over time: < 10 ms
Connection in parallel: no
Connection in series: No
Mains operation
Nominal output voltage: 120 VAC
Nominal output current (IN): 6 A (750 VA)
Battery operation
Nominal output voltage: 120 VAC
Nominal output current (IN): 6 A (750 VA)
Frequency (after automatic detection in mains operation): 50 Hz
60 Hz
Signal: Alarm
Output voltage: 24 V (SELV)
Continuous load current: ≤ 20 mA
Signal: Battery mode
Output voltage: 24 V (SELV)
Continuous load current: ≤ 20 mA
Signal: Ready
Output voltage: 24 V (SELV)
Continuous load current: ≤ 20 mA
Signal:
Signal ground SGnd: Reference potential for Bat.-Mode, Ready, Remote, and Bat.-Start
Energy storageNominal voltage UN: 24 VDC
Charging current: 0.7 A ... 1.1 A
Nominal capacity: 4 Ah
Nominal capacity range: 4 Ah
Charging time: 7 h
Buffer period: 20 min. (100 W)
4 min. (300W)
1 min. (600W)
Latest startup date (battery only): 6 Months (0°C ... 20°C)
Latest startup (battery only) - range: 6 Months ... 3 Months (20°C...30°C)
3 Months ... 1 Months (30°C ... 40°C)
Battery technology: Lead rechargeable battery module
Memory medium: Lead rechargeable battery module
Accumulator type: 2x Panasonic UP-VW1220P1 / BB Battery HR4.2-12FR
Can be extended with external battery: 1x 24 V 4 Ah
Battery fuse: 40 A, 32 V
Connection dataInput
Connection method: Push-in connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 4 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 10 mm
Output
Connection method: Push-in connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 4 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 10 mm
Signal
Connection method: Push-in connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 1.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 1.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 16
Stripping length: 8 mm
InterfacesInterface: MINI-USB type B
Maximum cable length: 3 m
SignalingTypes of signaling: LED
Signal output: Transistor output, active
Signalization designation: Alarm
Status display: LED
Color: red
Signal output: Transistor output, active​
Signalization designation: Battery mode
Status display: LED
Color: yellow
Signal output: Transistor output, active​​
Signalization designation: Ready
Signal output
Status display: LED
Color: green
Signal output​
Signalization designation: Battery charge
Status display: LED
Color: yellow
Signal output​​
Signalization designation: Service
Status display: LED
Color: red
Electrical propertiesNumber of phases: 1.00
Product propertiesProduct type: AC UPS
Product family: TRIO AC UPS – UPS with integrated energy storage
MTBF (IEC 61709, SN 29500): > 206000 h (40°C)
Insulation characteristics
Protection class: I
Overvoltage category: II
Degree of pollution: 3
Life expectancy (electrolytic capacitors)
Time: 32861 h
DimensionsWidth: 210 mm
Height: 170 mm
Depth: 136 mm
Installation dimensions
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 50 mm / 50 mm
MountingMounting type: DIN rail mounting
Material specificationsType of housing: DX51D+AZ (steel sheet / Galvalume)
Hood version: PC + ABS
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): 0°C ... 40°C
Ambient temperature (storage/transport): -15°C ... 40°C (with charged energy storage device)
Maximum altitude: ≤ 3000 m (> 2000 m, observe derating)
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (25°C, non-condensing)
Shock: 20g in all directions (EN 60068-2-27)
30g in each space direction with UWA 130
Vibration (operation): 5Hz...100Hz, 0.7g (EN60068-2-6)
Standards and regulationsStandards
Standard uninterruptible power supply systems: EN62040-1
ApprovalsUL approvals: UL/C-UL Recognized UL1778
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
Interference emission: Noise emission in accordance with EN62040-2
Noise immunity: Immunity in accordance with EN62040-2
Immunity in accordance with EN61000-6-1 (residential), EN61000-6-2 (industrial), and EN61000-6-5 (power station equipment zone), IEC/EN61850-3 (power supply)
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Conducted noise emission: EN62040-02 (Class C2)
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 6 kV (Test Level 3)
Discharge in air: 8 kV (Test Level 3)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 3 GHz
Test field strength: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 2 kV (Test Level 3 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Signal: 2 kV (Test Level 3 - asymmetrical)
Comments: Criterion A (B for USB)
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Input: 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Output: 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal: 1 kV (Test Level 2 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V
Power frequency magnetic field
Standards/regulations: EN61000-4-8
Frequency: 60 Hz
Test field strength: 100 A/m
Comments: Criterion A
Emitted interference
Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Technical Specs
ECLASSECLASS-11.0: 27040705
ECLASS-13.0: 27040705
ECLASS-12.0: 27040705
ETIMETIM 9.0: EC000382
UNSPSCUNSPSC 21.0: 39121000
Description
1AC/1AC/750 VA uninterruptible energy supply with integrated energy storage, lead AGM, VRLA technology, 24 V DC, 3.4 Ah for 120 V AC applications.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00250.pdf

Approvals_00251.pdf

Approvals_01254.pdf

Approvals_01255.pdf

Approvals_01418.pdf

Approvals_01617.pdf

Data_sheet_03882.pdf

Manufacturer_declaration_00983.pdf

Manufacturer_declaration_03089.pdf

Manufacturer_declaration_05509.pdf

Manufacturer_declaration_16087.pdf

Package_slip_01476.pdf

Package_slip_02256.pdf

Package_slip_02470.pdf

Technical_drawing_40207.pdf

Various_00006.pdf

Various_00047.pdf