PHOENIX CONTACTNot available

BLT-T2-320-UT - Type 2 surge arrester

Type 2 surge arrester for universal mounting in lights and cable connection boxes. Specifically for insulation class II with optical fault indication. Installation in branch or through wiring. Version: 230 V AC
Product Code: 2906100
Partner cod.: 2906100
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesIEC test classification: II / III
T2 / T3
EN type: T2 / T3
IEC power supply system: TT
TN-C
IT
Type: Installation module
Product type: Surge arrester
Surge protection fault message: optical
Insulation characteristics
Protection class: II
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal frequency fN: 50 Hz (60Hz)
Nominal voltage UN: 100 VAC ... 277 VAC
Dielectric strength: < 6 kV
Connection dataConnection method: Screw terminal blocks
Screw thread: M3
Tightening torque: 0.6 Nm
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section rigid: 0.2 mm² ... 4 mm²
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/9d19fe157ab7974780e2746e30c4dc4f/-S204x204-FJPG
Width: 36.5 mm
Height: 56 mm
Depth: 34 mm
Material specificationsFlammability rating according to UL 94: V-0
CTI value of material: 600
Insulating material: PA 6.6
Material group: I
Housing material: PA 6.6
Protective circuitMode of protection: L-N
Direction of action: 1L-N
Nominal voltage UN: 100 VAC ... 277 VAC
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous voltage UC: 320 VAC
Rated load current IL: 16 A
Nominal discharge current In (8/20) µs: 5 kA
Maximum discharge current Imax (8/20) µs: 10 kA
Combination wave UOC: 10 kV
Short-circuit current rating ISCCR: 3 kA
Voltage protection level Up: ≤ 1.3 kV
Residual voltage Ures: ≤ 1.3 kV (at In)
≤ 1.3 kV (at UOC)
TOV behavior at UT: 400 VAC (5s / withstand mode)
528 VAC (120min / safe failure mode)
Response time tA: ≤ 25 ns
Max. backup fuse with V-type through wiring: 16 A (MCB B/C)
Max. backup fuse with branch wiring: 16 A (MCB B/C)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 80°C
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 2000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Standards and regulationsStandards/specifications: IEC 61643-11
EN61643-11
Note: 2011
2012
MountingMounting type: 4 mm screw
Technical Specs
ECLASSECLASS-11.0: 27130805
ECLASS-13.0: 27171202
ETIMETIM 9.0: EC000941
UNSPSCUNSPSC 21.0: 39121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01861.pdf

Flyer_00001.pdf

Flyer_00002.pdf

Manufacturer_declaration_00821.pdf

Manufacturer_declaration_02199.pdf

Package_slip_00232.pdf

Product_information_00033.pdf

Product_information_00684.pdf