MINI MCR-2-T-2RO-PT - Limit value switch

Universally configurable temperature limit value switch with two transistor outputs for the connection of 2, 3, and 4-conductor resistance thermometers and thermocouples. Configurable via DIP switch or software, push-in connection technology
Product Code: 2906877
Partner cod.: 2906877
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Limit value switch
Product family: MINI Analog Pro
No. of channels: 1
Type: Signal conditioner
Configuration: DIP switches
Software
App
Insulation characteristics
Overvoltage category: II
Pollution degree: 2
System propertiesFunctionality
Configuration: DIP switches
Software
App
Electrical propertiesNo. of channels: 1
Switching point accuracy: < 0.1 %
Step response (0–99%): 300 ms
570 ms
380 ms
300 ms
570 ms
Maximum temperature coefficient: 0.01 %/K
Electrical isolation Input/output/power supply
Rated insulation voltage: 300 Vrms
Test voltage: 3 kV AC (50Hz, 60s)
Insulation: Reinforced insulation according to IEC/EN61010-1
Supply
Nominal supply voltage: 24 VDC
Supply voltage range: 9.6 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715)
Typical current consumption: 20 mA (12VDC)
10 mA (24VDC)
Power consumption: 350 mW
Input dataSignal
Number of inputs: 1
Measurement
Number of inputs: 1
Configurable/programmable: Yes
Sensor types (RTD) that can be used: Pt, Ni, Cu sensors
Sensor types that can be used (TC): B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Available input sources: Resistance thermometers
Thermocouples
Temperature measuring range: -250°C ... 2500°C (RTD)
≥ 20 K (RTD)
Sensor type:: 500°C ... 1820°C
-230°C ... 1000°C
-210°C ... 1200°C
-250°C ... 1372°C
-200°C ... 1300°C
-50°C ... 1768°C
-50°C ... 1768°C
-200°C ... 400°C
-200°C ... 900°C
-200°C ... 600°C
0°C ... 2500°C
0°C ... 1800°C
0°C ... 1800°C
-200°C ... 100°C
-200°C ... 800°C
Sensor input current:  200 µA (RTD)
Max. permissible overall conductor resistance: ≤ 25 Ω (Per line, RTD in 3- or 4-conductor technology)
≤ 50 Ω (adjustable, RTD in 2-conductor technology)
Linear resistance measuring range: 0 Ω ... 4000 Ω (RTD)
Linear mV signal range: -500 mV ... 500 mV (RTD)
Connection technology: 2-, 3-, 4-conductor
Output dataSwitching: Transistor
Number of outputs: 2
Contact switching type: 2 N/O contacts
Maximum switching voltage: 30 VDC
Max. switching current: 100 mA (30V)
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.2 mm² ... 2.5 mm² (with ferrule)
0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12 (flexible)
Ex dataEx installation (EPL): Gc
Div.2
InterfacesData: IFS interface
Connection method: Micro USB type B
SignalingStatus display: Green LED (supply voltage)
Yellow LED (switching output)
Error indication: Red LED
DimensionsWidth: 6.2 mm
Height: 109.81 mm
Depth: 119.2 mm
Material specificationsFire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
Housing material: PBT
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (not assessed by UL)
Ambient temperature (operation): -40°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
ATEX
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: BVS 20 ATEX E 024 X
UKCAEx(UKEX)
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: PxCIF21UKEX2902049X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECEx BVS 20.0017X
CCC/China-Ex
Identification: Ex nA IIC T4 Gc
Certificate: NEPSIGYJ21.1041X
UL, USA/Canada
Identification: UL508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Shipbuilding approval
Certificate: DNV GL TAA000021E Rev. 1
EACEx
Identification:  2Ex ec IIC T4 Gc
Certificate: BY/112 02.01 TP012 103.01 00081
DNV GL data
Temperature: B
Humidity: B
Vibration: A
EMC: A
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
MountingMounting type: DIN rail mounting
Assembly instructions: The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35mm EN60715 DIN rail.
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27210120
ECLASS-12.0: 27210120
ECLASS-13.0: 27210120
ETIMETIM 9.0: EC002653
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00128.pdf

Approvals_00172.pdf

Approvals_00173.pdf

Approvals_01460.pdf

Approvals_01500.pdf

Approvals_01944.pdf

Data_sheet_03894.pdf

Manual_00026.pdf

Manufacturer_declaration_00860.pdf

Manufacturer_declaration_01814.pdf

Manufacturer_declaration_16208.pdf

Manufacturer_declaration_17788.pdf

Package_slip_01626.pdf

Product_information_00033.pdf

Technical_drawing_40392.pdf