Industrial Automation
Notes | General: For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Product properties | Product type: Extension module Product family: PLC logic Operating mode: 100% operating factor Insulation characteristics Insulation: Basic insulation Insulation characteristics: Air clearances and creepage distances Insulation: Basic insulation Overvoltage category: III Pollution degree: 2 |
Electrical properties | Air clearances and creepage distances Rated insulation voltage: 50 V Rated surge voltage: 0.5 kV Supply Rated control circuit supply voltage US: 24 VDC Rated control supply voltage range with reference to US: 0.8 ... 1.1 Rated control supply current IS: 14 mA Protective circuit: Reverse polarity protection Surge protection |
Input data | Analog input resistance Sensor types (RTD) that can be used: Pt 100 (IEC 60751, ñ = 0,00385) Number of inputs: 1 Connection technology: 2-conductor Sensor input current: 900 µA Temperature measuring range: -50°C ... 200°C Maximum temperature coefficient: 0.01 %/K Maximum transmission error: 1 % Surge voltage protection: > 33 V Resolution: 10 bit (scaled to 0 to 1000) Analog input resistanceâ Sensor types (RTD) that can be used: Pt 1000 (IEC 60751, ñ = 0.00385) Number of inputs: 1 Connection technology: 2-conductor Sensor input current: 900 µA Temperature measuring range: -50°C ... 200°C Maximum temperature coefficient: 0.01 %/K Maximum transmission error: 1 % Surge voltage protection: > 33 V Resolution: 10 bit (scaled to 0 to 1000) |
Output data | Digital Output name: Digital output Switching voltage range: 5 VDC ... 30 VDC Switching current: ⤠3 mA |
Connection data | Connection method: Screw connection Stripping length: 8 mm Screw thread: M3 Conductor cross section rigid: 0.14 mm² ... 2.5 mm² Conductor cross section flexible: 0.14 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² (Single ferrule) 2x 0.5 mm² ... 1.5 mm² (TWIN ferrule) Conductor cross section AWG: 26 ... 14 Tightening torque: 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing)) |
Signaling | Operating voltage display: Green LED Error indication: Red LED |
Dimensions | Width: 6.2 mm Height: 80 mm Depth: 86 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -20°C ... 50°C Ambient temperature (storage/transport): -20°C ... 70°C |
Approvals | CE Certificate: CE-compliant UL, USA/Canada Identification: UL508 Listed |
Standards and regulations | Air clearances and creepage distances Standards/regulations: DINEN50178 |
Mounting | Mounting type: DIN rail mounting Assembly instructions: in rows with zero spacing Mounting position: any |
ECLASS | ECLASS-11.0: 27242201 ECLASS-13.0: 27242201 ECLASS-12.0: 27242201 |
ETIM | ETIM 9.0: EC001420 |
UNSPSC | UNSPSC 21.0: 32151600 |