Industrial Automation
Product properties | IEC power supply system: TN-S Type: Male Product type: Replacement plug Product family: SEC Family Number of positions: 2 Surge protection fault message: optical Insulation characteristics Overvoltage category: III Pollution degree: 2 IEC test classification: III T3 EN type: T3 Number of ports: One |
Connection data | Connection method: pluggable |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/25e5299f9f2d3a47963ae1591d8c2c5d/-S204x204-FJPG Width: 17.5 mm Height: 46.7 mm Depth: 65.7 mm Horizontal pitch: 1 Div. |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PA 6.6-FR 20 % GF PA 6.6-FR Housing material: PA 6.6-FR 20% GF PA 6.6-FR |
Protective circuit | Mode of protection: L-N L-PE N-PE Direction of action: 1L-N & N-PE Nominal voltage UN: 60VAC(TN-S) Nominal frequency fN: 50 Hz (60Hz) Maximum continuous voltage UC: 80 VAC Residual current IPE: ⤠5 µA Standby power consumption PC: ⤠5.3 mVA (at UREF) ⤠8.4 mVA (at UC) Reference test voltage UREF: 66 VAC Nominal discharge current In (8/20) µs: 2 kA Combination wave UOC: 4 kV Voltage protection level Up (L-N): ⤠0.48 kV Voltage protection level Up (L-PE): ⤠0.8 kV Voltage protection level Up (N-PE): ⤠0.8 kV TOV behavior at UT (L-N): 120 VAC (120min / safe failure mode) TOV behavior at UT (L-PE): 120 VAC (120min / withstand mode) Response time tA (L-N): ⤠25 ns Response time tA (L-PE): ⤠100 ns Response time tA (N-PE): ⤠100 ns Short-circuit current rating ISCCR: 10 kA AC Max. backup fuse with branch wiring: 32 A (gG / B / C) Additional technical data Short-circuit current rating ISCCR: 0.25 kA DC (Without additional backup fuse in the DC branch wiring) 5 kA DC (for 20 A gG / B backup fuse) Maximum discharge current Imax (8/20) µs: 4 kA Residual voltage Ures (L-N): ⤠0.42 kV (at 1 kA) ⤠0.48 kV (at 2 kA) ⤠0.4 kV (at UOC = 2 kV) Residual voltage Ures (L-PE): ⤠0.55 kV (at 1 kA) ⤠0.6 kV (at 2 kA) ⤠0.6 kV (at UOC = 2 kV) Residual voltage Ures (N-PE): ⤠0.55 kV (at 1 kA) ⤠0.6 kV (at 2 kA) ⤠0.6 kV (at UOC = 2 kV) Maximum continuous voltage UC: 80 VDC Mode of protection: (DC+) - (DC-) (DC+/DC-) - PE |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 80°C Ambient temperature (storage/transport): -40°C ... 80°C Altitude: ⤠6000 m (amsl) Permissible humidity (operation): 5 % ... 95 % Shock (operation): 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation): 5g (5...500Hz / 2.5h / X, Y, Z) |
Approvals | UL specifications Maximum continuous operating voltage MCOV: 100 VAC 80 VDC Nominal discharge current In: 3 kA Mode of protection: L-N L-G N-G (DC+) - (DC-) (DC+) - G (DC-) - G Nominal voltage: 80 VDC Power distribution system: Single phase DC Nominal frequency: 50/60 Hz Measured limiting voltage MLV (L-N): 490 V Measured limiting voltage MLV (L-G): 680 V Measured limiting voltage MLV (N-G): 680 V SPD Type: 4CA |
Standards and regulations | Standards/specifications: IEC 61643-11 Note: 2011 EN 61643-11 Standards/specifications: EN61643-11 Note: 2012 |
Mounting | Mounting type: on base element |
ECLASS | ECLASS-11.0: 27130890 ECLASS-13.0: 27171292 |
ETIM | ETIM 8.0: EC002496 |
UNSPSC | UNSPSC 21.0: 39121600 |
Description other products