Industrial Automation
PLT-SEC-T3-BE-FM-UT - Type 3 surge protection base element
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Product properties | IEC power supply system: TN-S TT Type: DIN rail module, two-section, divisible Product type: Base element Product family: SEC Family Number of positions: 2 Surge protection fault message: Remote indication contact Insulation characteristics Overvoltage category: III Pollution degree: 2 IEC test classification: II / III T2 / T3 EN type: T2 / T3 Number of ports: One |
Electrical properties | Indicator/remote signaling Connection name: Remote fault indicator contact Switching function: Changeover contact Operating voltage: 250 VAC 125 VDC (200 mA DC) Operating current: 0.5 A AC 0.5 ADC (75VDC) |
Connection data | Connection method: Screw connection Screw thread: M3 Tightening torque: 0.5 Nm Conductor cross section flexible: 0.2 mm² ... 2.5 mm² Conductor cross section rigid: 0.2 mm² ... 4 mm² Conductor cross section AWG: 24 ... 12 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/7bbef8e44094c94e8afcc4872555bcaf/-S204x204-FJPG Width: 17.7 mm Height: 93.4 mm Depth: 51.5 mm (incl. DIN rail 7.5mm) Horizontal pitch: 1 Div. |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PA 6.6-FR 20 % GF PA 6.6-FR Housing material: PA 6.6-FR 20% GF PA 6.6-FR |
Mechanical properties | Mechanical data Open side panel: No |
Protective circuit | Direction of action: 1L-N & N-PE Nominal voltage UN: 240VAC(TN-S) 240VAC(TT) Nominal frequency fN: 50 Hz (60Hz) Maximum continuous voltage UC: 264 VAC Rated load current IL: 26 A (at 30°C) Short-circuit current rating ISCCR: 10 kA AC Max. backup fuse with branch wiring: depends on the plug used Additional technical data Short-circuit current rating ISCCR: max. 5 kA DC (depends on the plug used) Maximum continuous voltage UC: 240 VDC |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 80°C Ambient temperature (storage/transport): -40°C ... 80°C Altitude: ⤠2000 m (amsl) Permissible humidity (operation): 5 % ... 95 % Shock (operation): 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation): 5g (5...500Hz / 2.5h / X, Y, Z) |
Approvals | UL specifications Nominal voltage: 240 VDC Rated load current IL: 20 A Power distribution system: Single phase DC Nominal frequency: 50/60 Hz SPD Type: ACC UL indicator/remote signaling Operating voltage: 250 VAC (0.5A) DC operating voltage: 12 VDC (4A) 24 VDC (2A) 48 VDC (1A) UL connection data Tightening torque: 4.4 lbf-in. Conductor cross section AWG: 16 ... 12 |
Standards and regulations | Standards/specifications: IEC 61643-11 Note: 2011 EN 61643-11 Standards/specifications: EN61643-11 Note: 2012 |
Mounting | Mounting type: DIN rail: 35 mm |
ECLASS | ECLASS-11.0: 27130803 ECLASS-13.0: 27171292 |
ETIM | ETIM 8.0: EC000472 |
UNSPSC | UNSPSC 21.0: 39121600 |