Industrial Automation
EEM-MB370 - Measuring instrument
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Product properties | Product type: Energy measuring device Product family: EMpro Insulation characteristics Overvoltage category: III (300V) Pollution degree: 2 |
Electrical properties | Electrical isolation: IEC 61010-1 (Overvoltage category III at 300VACOvervoltage category II at 600VAC) IEC 61010-1 (Measurement category III at 300VACMeasurement category II at 600VAC) Test voltage: 4 kV AC (50Hz, 60s) Maximum power dissipation for nominal condition: 10 VA Mains type: 3-phase (3 or 4-conductor), 2-phase (2-conductor), and single-phase (1-conductor) Supply Supply voltage range: 100 VAC ... 230 VAC (±20%) 150 VDC ... 250 VDC (±20%) Power consumption: ⤠4 W Nominal frequency: 50 Hz ... 60 Hz (AC sine) |
Input data | General Measuring principle: True r.m.s. value measurement (TRMS) Measured value: ACsine (50/60 Hz) Acquisition of harmonics: up to 63rd harmonic Description of the input: Digital input in accordance with IEC/EN61131-2 (type 3) Number: 1 Voltage input signal: 24 VDC 0 VDC ... 30 VDC Current input signal: 2 mA ... 15 mA Protection: 250 mA (fast-blow) Measurement: Voltage Input name: Voltage measuring input V1, V2, V3 Input voltage range direct: 35 VAC ... 690 VAC (Phase/Phase) 20 VAC ... 400 VAC (Phase/neutral conductor) Input voltage range via external transformers: 60 VAC ... 2000000 VAC (primary) 60 VAC ... 400 VAC (secondary) Surge voltage capacity: 760 VAC (Phase/Phase) Precision: 0.2 % Power consumption: < 2 VA Measurement: Current Input name: Current measurement I1, I2, I3 Input current: 1 A (secondary) 5 A (secondary) Current measuring range: 1 A ... 20000 A (primary) Overload capacity: 6 A (Imax) Response threshold from measuring range nominal value: 10 mA (1A) 50 mA (5A) Precision: 0.2 % Current overload: 50 A for 1 s Power consumption: < 0.5 VA Measurement: Power Precision: 0.5 % Active energy (IEC 62053-22): Class 0.5S Reactive power (IEC 62053-23): Class2 ANSI C12.20: Class 0.5S |
Output data | Output description: Digital output in accordance with IEC/EN61131-2 (type 3) Number: 1 Current output signal: ⤠100 mA Voltage output signal: 24 VDC Protection: 250 mA (fast-blow) |
Connection data | Current/voltage/supply Connection method: Screw connection Stripping length: 8 mm Screw thread: M3 Conductor cross section rigid: 0.2 mm² ... 6 mm² Conductor cross section flexible: 0.2 mm² ... 4 mm² Conductor cross section AWG: 24 ... 10 Tightening torque: 0.5 Nm ... 0.6 Nm Digital I/O/communication Connection method: Screw connection Stripping length: 7 mm Screw thread: M3 Conductor cross section rigid: 0.14 mm² ... 2.5 mm² Conductor cross section flexible: 0.14 mm² ... 1.5 mm² Conductor cross section AWG: 26 ... 14 Tightening torque: 0.5 Nm ... 0.6 Nm |
Interfaces | Data: Network interface Communication protocol: Modbus/TCP REST Connection method: RJ45 |
Dimensions | Width: 90 mm Height: 90 mm Depth: 71.7 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection (Housing): IP20 (Housing) Ambient temperature (operation): -25°C ... 70°C Ambient temperature (storage/transport): -30°C ... 80°C Altitude: ⤠2000 m Max. permissible relative humidity (operation): ⤠95 % (non-condensing) |
Approvals | CE Certificate: CE-compliant UKCA Certificate: UKCA-compliant UL, USA/Canada Identification: UL/C-UL Listed UL61010-1 UL data Operating mode: Indoor use UL dataâ Operating mode: Indoor use |
Mounting | Mounting type: DIN rail mounting Mounting position: Horizontal DIN rail |
ECLASS | ECLASS-11.0: 27142330 ECLASS-12.0: 27142330 ECLASS-13.0: 27142330 |
ETIM | ETIM 9.0: EC002301 |
UNSPSC | UNSPSC 21.0: 41113600 |