PHOENIX CONTACT 2908065
PHOENIX CONTACT 2908065
PHOENIX CONTACTNot available

MACX MCR-IDS-2I-2I - Output signal conditioner

2-channel output signal conditioner, HART-transparent. Isolates and transmits 0/4mA...20mA signals to a load in the safe area. 4-way electrical isolation, line fault detection, SIL2 (SC3) in accordance with IEC61508, screw connection.
Product Code: 2908065
Partner cod.: 2908065
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Output signal conditioner
Product family: MACX Analog
No. of channels: 2
Type: Signal conditioners with SIL functional safety
Electrical propertiesNo. of channels: 2
Electrical isolation: 4-way isolation
Signal transmission behavior: In=Out
Step response (10-90%): < 140 µs (for 4 mA ... 20 mA step)
Maximum temperature coefficient: 0.01 %/K
Temperature coefficient, typical: ≤ 0.005 %/K
Maximum transmission error: 0.1 % (of final value)
Transmission error, typical: ≤ 0.05 % (of final value)
Electrical isolation​
Overvoltage category: II
Pollution degree: 2
Electrical isolation Input/output IEC/EN61010-1
Standards/regulations: IEC/EN61010-1
Rated insulation voltage: 300 Vrms
Test voltage: 2.5 kV AC (50Hz, 60s)
Insulation: Safe isolation
Electrical isolation Input/power supply IEC/EN61010-1
Standards/regulations: IEC/EN61010-1
Rated insulation voltage: 50 Vrms
Test voltage: 1.5 kV AC (50Hz, 60s)
Insulation: Basic insulation
Electrical isolation Output/supply IEC/EN61010-1
Standards/regulations: IEC/EN61010-1
Rated insulation voltage: 300 Vrms
Test voltage: 2.5 kV AC (50Hz, 60s)
Insulation: Safe isolation
Electrical isolation Input1/input2, output1/output2
Test voltage: 1.5 kV AC (50Hz, 60s)
Supply
Nominal supply voltage: 24 VDC -20%...+25%
Supply voltage range: 19.2 VDC ... 30 VDC
Max. current consumption: < 85 mA (24VDC / 20mA)
Power dissipation: < 1.4 W (24VDC / 20mA)
Power consumption: ≤ 2 W (24VDC / 20mA)
Input dataSignal: Current
Current input signal: 0.2 mA ... 20 mA (Function)
4 mA ... 20 mA (Safety)
0 mA ... 24 mA (Underload/overload range)
Input current: ≤ 30 mA
Input impedance: > 1 MΩ (If there is a line fault)
Line fault detection: > 0.2 mA (Response threshold of input current)
Voltage drop: < 2.4 V (at 20 mA)
Output dataSignal: Current
Number of outputs: 2
Current output signal: 0.2 mA ... 20 mA (Function)
4 mA ... 20 mA (Safety)
0 mA ... 24 mA (Underload/overload range)
Load: 100 Ω ... 700 Ω (20mA)
100 Ω ... 650 Ω (20.5mA)
100 Ω ... 500 Ω (24mA)
Output ripple: < 20 mVrms
Non-load voltage: ≤ 27 V
Line fault detection: > 10 kΩ (Line break)
< 50 Ω (Short circuit)
Connection dataConnection method: Screw connection
Stripping length: 7 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 14
Tightening torque: 0.5 Nm ... 0.6 Nm
COMBICON connection
Max. diameter: 2 mm
Ex dataEx installation (EPL): Gc
Div.2
InterfacesData communication (bypass)
HART function: Yes
Protocols supported: HART-transparent
SignalingStatus display: Green LED (supply voltage)
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3edd36290ae8094db8e0add7aa964a6f/-S204x204-FJPG
Width: 12.5 mm
Height: 112.5 mm
Depth: 113.7 mm
Depth NS35/7,5: 114.5 mm (Snapped onto DIN rail NS35/7,5 in accordance with EN60715)
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Housing material: PA 6.6-FR
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 70°C (Any mounting position)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Altitude range (≤ 2000 m (Ex))
Description: Ex applications
Altitude: ≤ 2000 m (The technical data refers to altitudes ≤2000m above mean sea level. For altitudes >2000m above mean sea level, refer to the data sheet.)
Ambient temperature (operation): -40°C ... 70°C
Rated insulation voltage: 320 V (Power supply, input / output)
Altitude range (≤ 3000 m (Ex))
Description: Ex applications
Height range: > 2000 m ... 3000 m
Ambient temperature (operation): -40°C ... 60°C
Rated insulation voltage: 190 V (Power supply, input / output)
Altitude range (≤ 4000 m (Ex))
Description: Ex applications
Height range: > 3000 m ... 4000 m
Ambient temperature (operation): -40°C ... 55°C
Rated insulation voltage: 63 V (Power supply, input / output)
Altitude range (≤ 5000 m (Ex))
Description: Ex applications
Height range: > 4000 m ... 5000 m
Ambient temperature (operation): -40°C ... 45°C
Rated insulation voltage: 63 V (Power supply, input / output)
Altitude range (≤ 2000 m)
Description: Non-Ex applications (EN61010-1)
Altitude: ≤ 2000 m (The technical data refers to altitudes ≤2000m above mean sea level. For altitudes >2000m above mean sea level, refer to the data sheet.)
Ambient temperature (operation): -40°C ... 70°C
Rated insulation voltage: 300 V (Power supply, input / output)
Altitude range (≤ 3000 m)
Description: Non-Ex applications (EN61010-1)
Height range: > 2000 m ... 3000 m
Ambient temperature (operation): -40°C ... 60°C
Rated insulation voltage: 150 V (Power supply, input / output)
Altitude range (≤ 4000 m)
Description: Non-Ex applications (EN61010-1)
Height range: > 3000 m ... 4000 m
Ambient temperature (operation): -40°C ... 55°C
Rated insulation voltage: 150 V (Power supply, input / output)
Altitude range (≤ 5000 m)
Description: Non-Ex applications (EN61010-1)
Height range: > 4000 m ... 5000 m
Ambient temperature (operation): -40°C ... 45°C
Rated insulation voltage: 150 V (Power supply, input / output)
ApprovalsCE
Certificate: CE-compliant
Note: and EN61326
ATEX
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: BVS 20 ATEX E 003 X
UKCAEx(UKEX)
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: PxCIF21UKEx2908065X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECEx BVS 20.0003X
CCC/China-Ex
Identification: Ex ec IIC T4 Gc
Certificate: 2021122304114079
UL, USA/Canada
Identification: UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Shipbuilding approval
Certificate: DNV GL TAA00000AG
Safety Integrity Level (SIL, IEC 61508)
Identification: 3
Systematic Capability
Identification: 3
INMETRO
Identification: Ex ec IIC T4 Gc
Certificate: DNV 21.0092 X
EAC
Identification: 2Ex e IIC T4 Gc X
Certificate: RU C-DE.HB49.B.00145/21
DNV GL data
Temperature: B
Humidity: B
Vibration: A
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Standards and regulationsElectrical isolation: 4-way isolation
GBStandard
Standards/regulations: GB/T3836.1
GB/T3836.3
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27210120
ECLASS-12.0: 27210120
ECLASS-13.0: 27210120
ETIMETIM 8.0: EC002653
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01172.pdf

Approvals_01413.pdf

Approvals_01414.pdf

Approvals_01436.pdf

Data_sheet_03912.pdf

Manufacturer_declaration_01382.pdf

Manufacturer_declaration_02289.pdf

Manufacturer_declaration_16309.pdf

Manufacturer_declaration_17786.pdf

Package_slip_01545.pdf

Technical_drawing_40578.pdf