Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2908285
PHOENIX CONTACTNot available

EEM-MA771-R - Measuring instrument

Multi-functional energy measuring device with direct Rogowski connection and integrated ModbusRTU/TCP interface for measuring electrical parameters in low-voltage installations up to 690V. (phoenixcontact.com/empro-help)
Product Code: 2908285
Partner cod.: 2908285
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Energy measuring device
Product family: EMpro
Insulation characteristics
Overvoltage category: III (300V)
Pollution degree: 2
Electrical propertiesElectrical isolation: IEC 61010-1 (Overvoltage category III at 300VACOvervoltage category II at 600VAC)
IEC 61010-1 (Measurement category III at 300VACMeasurement category II at 600VAC)
Test voltage: 4 kV AC (50Hz, 60s)
Maximum power dissipation for nominal condition: 10 VA
Mains type: 3-phase (3 or 4-conductor), 2-phase (2-conductor), and single-phase (1-conductor)
Supply
Supply voltage range: 100 VAC ... 400 VAC (±20%)
150 VDC ... 250 VDC (±20%)
Power consumption: ≤ 4 W
Nominal frequency: 50 Hz ... 60 Hz (AC sine)
Input dataGeneral
Measuring principle: True r.m.s. value measurement
Measured value: ACsine (50/60 Hz)
Acquisition of harmonics: up to 63rd harmonic
Description of the input: Digital input in accordance with IEC/EN61131-2 (type 3)
Number: 1
Voltage input signal: 24 VDC
0 VDC ... 30 VDC
Current input signal: 2 mA ... 15 mA
Protection: 250 mA (fast-blow)
Measurement: Voltage
Input name: Voltage measuring input V1, V2, V3
Input voltage range direct: 35 VAC ... 690 VAC (Phase/Phase)
20 VAC ... 400 VAC (Phase/neutral conductor)
Input voltage range via external transformers: 60 VAC ... 2000000 VAC (primary)
60 VAC ... 400 VAC (secondary)
Surge voltage capacity: 760 VAC (Phase/Phase)
Precision: 0.2 %
Power consumption: < 2 VA
Measurement: Current
Input name: Current measurement RC1, RC2, RC3
Input current: ≤ 400 A (Measurement level1)
≤ 4000 A (Measurement level2)
Input measuring range voltage: 500 µV ... 400 mV (1000 A)
Response threshold from measuring range nominal value: 5 A
Operate threshold: 500 µV (5A)
Precision: 0.5 %
Secondary current: ≤ 500 mV (Imax)
Measurement: Power
Precision: 1 %
Real energy (IEC 62053-21): Class1
Reactive power (IEC 62053-23): Class2
Output dataOutput description: Digital output in accordance with IEC/EN61131-2 (type 3)
Number: 1
Current output signal: ≤ 100 mA
Voltage output signal: 24 VDC
Protection: 250 mA (fast-blow)
Connection dataCurrent/voltage/supply
Connection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 6 mm²
Conductor cross section flexible: 0.2 mm² ... 4 mm²
Conductor cross section AWG: 24 ... 10
Tightening torque: 0.5 Nm ... 0.6 Nm
Digital I/O/communication
Connection method: Screw connection
Stripping length: 7 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 1.5 mm²
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.5 Nm ... 0.6 Nm
RS-485
Connection method: Screw connection
Stripping length: 7 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
Tightening torque: 0.5 Nm ... 0.6 Nm
InterfacesData: Network interface
Communication protocol: Modbus/TCP
REST
Connection method: RJ45
Data: Network interface​
Communication protocol: Modbus/RTU
Communication standard: RS-485
Connection method: Screw connection
Transmission speed range: 2.4 kbps ... 115.2 kbps
Resistance: 120 Ω (integrated)
DimensionsWidth: 96 mm
Height: 96 mm
Depth: 58 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection (Housing): IP20 (Housing)
Degree of protection (Display): IP54 (Display (+ EEM-MA-IP))
Ambient temperature (operation): -25°C ... 70°C
Ambient temperature (storage/transport): -30°C ... 80°C
Altitude: ≤ 2000 m
Max. permissible relative humidity (operation): ≤ 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA/Canada
Identification: UL/C-UL Listed UL61010-1
UL data
Operating mode: Indoor use
UL data​
Operating mode: Indoor use
MountingMounting type: Panel mount
Mounting position: Front panel installation, horizontal
Technical Specs
ECLASSECLASS-11.0: 27142330
ECLASS-12.0: 27142330
ECLASS-13.0: 27142330
ETIMETIM 9.0: EC002301
UNSPSCUNSPSC 21.0: 41113600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00078.pdf

Approvals_01227.pdf

Approvals_01228.pdf

Manual_00220.pdf

Manufacturer_declaration_01121.pdf

Manufacturer_declaration_02259.pdf

Manufacturer_declaration_16336.pdf

Package_slip_00927.pdf

Product_information_00033.pdf

Product_information_00719.pdf

Technical_drawing_40612.pdf