EEM-MA771-EIP - Measuring instrument

Multifunctional energy measuring device with direct Rogowski connection and integrated Modbus/TCP and EtherNet/IPâ„¢ interface for measuring electrical parameters in low-voltage installations up to 690V. (phoenixcontact.com/empro-help)
Product Code: 2908302
Partner cod.: 2908302
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
Product propertiesProduct type: Energy measuring device
Product family: EMpro
Insulation characteristics
Overvoltage category: III (300ÂV)
Pollution degree: 2
Electrical propertiesElectrical isolation: IEC 61010-1 (Overvoltage category III at 300ÂVÂACOvervoltage category II at 600ÂVÂAC)
IEC 61010-1 (Measurement category III at 300ÂVÂACMeasurement category II at 600ÂVÂAC)
Test voltage: 4 kV AC (50ÂHz, 60Âs)
Maximum power dissipation for nominal condition: 10 VA
Mains type: 3-phase (3 or 4-conductor), 2-phase (2-conductor), and single-phase (1-conductor)
Supply
Supply voltage range: 100 VÂAC ... 400 VÂAC (±20Â%)
150 VÂDC ... 250 VÂDC (±20Â%)
Power consumption: ≤ 4 W
Nominal frequency: 50 Hz ... 60 Hz (AC sine)
Input dataGeneral
Measuring principle: True r.m.s. value measurement
Measured value: ACÂsine (50/60 Hz)
Acquisition of harmonics: up to 63rd harmonic
Description of the input: Digital input in accordance with IEC/ENÂ61131-2 (type 3)
Number: 1
Voltage input signal: 24 VÂDC
0 VÂDC ... 30 VÂDC
Current input signal: 2 mA ... 15 mA
Protection: 250 mA (fast-blow)
Measurement: Voltage
Input name: Voltage measuring input V1, V2, V3
Input voltage range direct: 35 VÂAC ... 690 VÂAC (Phase/Phase)
20 VÂAC ... 400 VÂAC (Phase/neutral conductor)
Input voltage range via external transformers: 60 VÂAC ... 2000000 VÂAC (primary)
60 VÂAC ... 400 VÂAC (secondary)
Surge voltage capacity: 760 VÂAC (Phase/Phase)
Precision: 0.2 %
Power consumption: < 2 VA
Measurement: Current
Input name: Current measurement RC1, RC2, RC3
Input current: ≤ 400 A (Measurement levelÂ1)
≤ 4000 A (Measurement levelÂ2)
Input measuring range voltage: 500 µV ... 400 mV (1000 A)
Response threshold from measuring range nominal value: 5 A
Operate threshold: 500 µV (5ÂA)
Precision: 0.5 %
Measurement: Power
Precision: 1 %
Real energy (IEC 62053-21): ClassÂ1
Reactive power (IEC 62053-23): ClassÂ2
Output dataOutput description: Digital output in accordance with IEC/ENÂ61131-2 (type 3)
Number: 1
Current output signal: ≤ 100 mA
Voltage output signal: 24 VÂDC
Protection: 250 mA (fast-blow)
Connection dataCurrentÂ/ÂvoltageÂ/Âsupply
Connection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 6 mm²
Conductor cross section flexible: 0.2 mm² ... 4 mm²
Conductor cross section AWG: 24 ... 10
Tightening torque: 0.5 Nm ... 0.6 Nm
Digital I/OÂ/Âcommunication
Connection method: Screw connection
Stripping length: 7 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 1.5 mm²
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.5 Nm ... 0.6 Nm
InterfacesData: Network interface
Communication protocol: Modbus/TCP
REST
Connection method: RJ45
Data: Network interfaceâۉ€¹
Communication protocol: EtherNet/IPâ„¢
Connection method: RJ45
Number of connections: 2
Note: DLR ready
DimensionsWidth: 96 mm
Height: 96 mm
Depth: 75 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection (Housing): IP20 (Housing)
Degree of protection (Display): IP54 (Display (+ EEM-MA-IP))
Ambient temperature (operation): -10°C ... 55°C
Ambient temperature (storage/transport): -40°C ... 70°C
Altitude: ≤ 2000 m
Max. permissible relative humidity (operation): ≤ 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA/Canada
Identification: UL/C-UL Listed ULÂ61010-1
UL data
Operating mode: Indoor use
UL dataâۉ€¹
Operating mode: Indoor use
MountingMounting type: Panel mount
Mounting position: Front panel installation, horizontal
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00078.pdf

Approvals_01227.pdf

Approvals_01228.pdf

Manual_00220.pdf

Manufacturer_declaration_01121.pdf

Manufacturer_declaration_02259.pdf

Manufacturer_declaration_16339.pdf

Package_slip_00926.pdf

Product_information_00033.pdf

Product_information_00722.pdf

Technical_drawing_40616.pdf