Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2908581
PHOENIX CONTACTNot available

EEM-EM375 - Measuring instrument

Three-phase power meter for active power measurement with current transformer measurement 1A/5A in networks of up to 500V, with S0 output, Ethernet interface, certified in accordance with the MID directive
Product Code: 2908581
Partner cod.: 2908581
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Energy meter
Insulation characteristics
Protection class: II (EN50470-1)
Insulation characteristics​
Pollution degree: 2
Electrical propertiesElectric strength: 6 kV
4 kV (EN50470-3, 7.2)
Supply
Supply voltage range: Supply from the measuring circuit
Input dataMeasurement
Input voltage range: 3x 184 V ... 288 V (320V...500V)
Input current range: up to transformer ratio 10000
Power consumption: 3.5 VA (1W)
Frequency range: 45 Hz ... 65 Hz
Start current Ist: 0.002 A
Minimal current Imin: 0.01 A
Maximum current Imax: 6 A
Transient current Itr: 0.05 A
Nominal current Iref: 1 A
Secondary rated current Isn: 1 A
5 A
Current transformer ratio: 1 ... 10000 (max. 10000/1 or 50000/5)
Current transformer load: 1.5 mΩ
Energy (EN 50470-3): ClassB
Real energy (IEC 62053-21): Class1
Reactive power (IEC 62053-23): Class2
Output dataS0 output
Output description: Passive opto-isolated
Maximum switching voltage: 27 VDC
Max. switching current: 27 mA
Pulse time: 50 ms ±2ms
Pause time: 30 ms ±2ms
Pulse LED: 10000imp/kWh
Meter constant: 100imp/kWh, kVAh, kvarh
1000imp/kWh, kVAh, kvarh (CT 1...4)
200imp/kWh, kVAh, kvarh (CT 5...24)
40imp/kWh, kVAh, kvarh (CT 25...124)
8imp/kWh, kVAh, kvarh (CT 125...624)
1imp/kWh, kVAh, kvarh (CT 625...3124)
0.1imp/kWh, kVAh, kvarh (CT 3125...10000)
Connection dataMeasurement connection
Connection method: Screw connection
Conductor cross section rigid: 1.5 mm² ... 6 mm²
Conductor cross section flexible: 1.5 mm² ... 6 mm²
Conductor cross section AWG: 16 ... 10 (rigid/flexible)
Tightening torque: 1.5 Nm
Other connections
Connection method: Screw connection
Conductor cross section rigid: 0.14 mm² ... 1.5 mm²
Conductor cross section flexible: 0.14 mm² ... 1.5 mm²
Conductor cross section AWG: 26 ... 16 (rigid/flexible)
Tightening torque: 0.5 Nm
InterfacesCommunication
Communication protocol: Modbus/TCP
HTTP
NTP
DHCP
FTP
Communication standard: IEEE 802.3
Connection method: RJ45
Transmission speed range: 10 Mbps ... 100 Mbps
DimensionsWidth: 72 mm
Height: 90 mm
Depth: 67 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection (Front): IP51 (Front)
Degree of protection (Connections): IP20 (Connections)
Ambient temperature (operation): -25°C ... 55°C
Ambient temperature (storage/transport): -25°C ... 75°C
Max. permissible relative humidity (operation): 80 %
ApprovalsCE
Certificate: CE-compliant
MID
Identification: MID-compliant
Standards and regulationsStandards/specifications: EN50470-1
EN50470-3
Technical Specs
ECLASSECLASS-11.0: 27142330
ECLASS-12.0: 27142330
ECLASS-13.0: 27142330
ETIMETIM 9.0: EC002301
UNSPSCUNSPSC 21.0: 41113600
Description
Three-phase power meter for active power measurement with current transformer measurement 1 A / 5 A in networks of up to 500 V, with S0 output, Ethernet interface, certified in accordance with the MID directive
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Manual_00096.pdf

Manufacturer_declaration_01042.pdf

Package_slip_00912.pdf

Product_information_00033.pdf

Product_information_00729.pdf

Technical_drawing_40662.pdf