Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2908672
PHOENIX CONTACT 2908672
PHOENIX CONTACTNot available

ELR H3-IES-PT/500AC-9-IOL - Hybrid motor starter

Networkable hybrid motor starter for starting 3~AC motors up to 500VAC and 9A output current, with adjustable overload shutdown, emergency stop function up to SIL3/PLe, and Push-in connection. Connection to IO-Link.
Product Code: 2908672
Partner cod.: 2908672
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesGeneral: If this device is to be used in combination with the CrossPowerSystem power distribution board, the device mount for the 16 A fuse (order designation: EM-CPS-DA-22,5F/16A; order number: 1002668) is required in order to attach the hybrid motor starter to the power distribution board.
Product propertiesProduct type: Hybrid motor starters
Product family: CONTACTRON
Operating mode: 100% operating factor
Electrical propertiesNumber of phases: 3
Motor starter type: Direct starter
Switching frequency: ≤ 2 Hz (Load-dependent)
Maximum power dissipation: 7 W
Minimum power dissipation: 0.88 W
Coordination type: 1
Supply
Rated control circuit supply voltage US: 24 VDC
Control supply voltage range: 19.2 VDC ... 30 VDC
Rated control supply current IS: 65 mA
Protective circuit: Surge protection
Reverse polarity protection; Parallel polarity protection diode
Supply: IO-Link
Nominal voltage for I/O supply: 24 VDC (This supply voltage is provided via the IO-Link interface of the IO-Link master.)
Current consumption: typ. 65 mA ±15% (24VDC)
max. 150 mA
Protective circuit: Reverse polarity protection
Short-circuit protection
Overload protection
Insulation characteristics
Rated insulation voltage: 550 V
Rated surge voltage: 6 kV
Overvoltage category: III
Degree of pollution: 2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit: Safe isolation (IEC 60947-1)
Isolation characteristics between the control input and control supply voltage to auxiliary circuit: Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Emergency tripping
Operate threshold: > 60 A
Response time: < 0.5 s
Input dataControl
Input name: Enable input
Rated actuating voltage UC: 24 VDC
Triggering voltage range: 19.2 VDC ... 30 VDC
Rated actuating current IC: 7 mA
Switching threshold: 9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level: < 5 VDC (For EMERGENCY STOP)
Typical turn-off time: < 30 ms
IO-Link
Number of ports: 1
Connection method: COMBICON
Connection technology: 3-conductor
Specification: V1.1.1
Reverse polarity protection: yes
Cycle Time: 30 ms
Amount of process data: 8 Byte (Input data)
2 Byte (Output data)
Output dataAC output
Rated operating voltage Ue: 500 VAC
Operating voltage range: 42 VAC ... 550 VAC
Rated operating current Ie: 9 A (AC-51)
7 A (AC-53a)
Mains frequency: 50/60 Hz
Load current range: 1.5 A ... 9 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2: Class 10A
Cooling time: 20 min. (for auto reset)
Leakage current: 0 mA
Protective circuit: Surge protection; Varistor
Connection dataControl circuits
Connection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 14
Load circuit
Connection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 14
SignalingStatus display: Yellow LED
Operating voltage display: Green LED
Error indication: Red LED
DimensionsWidth: 22.5 mm
Height: 127 mm
Depth: 114 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -5°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 2000 m
ApprovalsUKCA
Certificate: UKCA-compliant
UL approval
Certificate: NLDX.E228652
NRNT.E172140
Safety Integrity Level (SIL, IEC 61508)
Identification: ≤3
Note: Safe shutdown
Performance Level (ISO13849)
Identification: e
Note: Safe shutdown
Category (ISO13849)
Identification: ≤3
Note: Safe shutdown
UL data
SCCR: 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (480 V AC (fuse: 20 A RK5 (standard fault)))
FLA: 7.6 A (480VAC)
Group installation: 20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded)
Category code: NLDX / NRNT
Horsepower ratings: 2 hp (208VAC)
2 hp (230 V AC)
2 hp (240VAC)
5 hp (480VAC)
Standards and regulationsStandards/regulations
Standards/regulations: IEC 60947-1
EN60947-4-2
IEC 61508
ISO13849
MountingMounting type: DIN rail mounting
Assembly instructions: alignable, for spacing see derating
Mounting position: vertical (horizontal DIN rail, motor output below)
Technical Specs
ECLASSECLASS-11.0: 27370905
ECLASS-13.0: 27370905
ECLASS-12.0: 27370905
ETIMETIM 9.0: EC001037
UNSPSCUNSPSC 21.0: 25173900
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00076.pdf

Application_note_00183.pdf

Approvals_00051.pdf

Approvals_00052.pdf

Data_sheet_03916.pdf

Manufacturer_declaration_01007.pdf

Manufacturer_declaration_02103.pdf

Manufacturer_declaration_04853.pdf

Manufacturer_declaration_16372.pdf

Package_slip_00946.pdf

Technical_drawing_40675.pdf