Industrial Automation
Product properties | Product type: System cable |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Degree of protection (Installation location): ⥠IP54 (Installation location) Ambient temperature (operation): -40°C ... 70°C (fixed installation) -10°C ... 70°C (flexible installation) Ambient temperature (storage/transport): -40°C ... 80°C Altitude: ⤠2000 m |
Electrical properties | Operating voltage (AC): ⤠30 VAC Operating voltage (DC): ⤠60 VDC Nominal operating mode: 100% operating factor Current (Per path): ⤠2 A (Uncoiled, see derating) |
Cable/line | Cable length: 1.5 m 25X0.25[PVC] UL AWM Style: 2464/1061 Number of positions: 25 Shielded: yes Cable type: 25X0.25[PVC] Conductor type: Assembled shielded round cable Conductor structure signal line: 14x 0.15 mm AWG signal line: 24 Conductor cross section: 25x 0.25 mm² Wire diameter incl. insulation: 1.2 mm ±0.05 mm External cable diameter: 9.8 mm ±0.5 mm Outer sheath, material: Semi-rigid PVC External sheath, color: gray Conductor material: Bare Cu litz wires Cable resistance: ⤠80 é/km (at 20°C) Insulation resistance: ⥠20 Mé*km (at 20°C) Smallest bending radius, fixed installation: 82 mm Smallest bending radius, movable installation: 155 mm Max. bending cycles: 5000 (at a radius of ⥠15x outside diameter) Halogen-free: no Flame resistance: IEC 60332-1-2 (raw cable) VDE0842, Part332-1-2 (raw cable) IEC 60332-3-22 (raw cable) ULVW-1 CSA FT-1 Resistance to oil: can withstand occasional splashes (raw cable) color code D-SUB25 (1): () = white D-SUB25 (2): () = brown D-SUB25 (3): () = green D-SUB25 (4): () = yellow D-SUB25 (5): () = gray D-SUB25 (6): () = pink D-SUB25 (7): () = blue D-SUB25 (8): () = red D-SUB25 (9): () = black D-SUB25 (10): () = violet D-SUB25 (11): () = gray-pink D-SUB25 (12): () = red-blue D-SUB25 (13): () = white-green D-SUB25 (14): () = brown-green D-SUB25 (15): () = white-yellow D-SUB25 (16): () = yellow-brown D-SUB25 (17): () = white-gray D-SUB25 (18): () = gray-brown D-SUB25 (19): () = white-pink D-SUB25 (20): () = pink-brown D-SUB25 (21): () = white-blue D-SUB25 (22): () = brown-blue D-SUB25 (23): () = white-red D-SUB25 (24): () = brown-red D-SUB25 (25): () = white-black |
Connection data | Connection 1 Connection method: Single wires Stripping length (Sheath): ï» 150 mm Number of positions: 25 Note: The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end. Connection 2 Connection in acc. with standard: IEC 60807-2 DIN41652 Connection method: D-SUB socket strip Screw thread: UNC 4-40 Number of connections: 1 Number of positions: 25 Tightening torque: 0.2 Nm Insertion/withdrawal cycles: > 200 Pitch: 2.77 mm |
Notes | General: No additional touch protection is required when using a SELV/PELV voltage (â¤30VAC or 60VDC). For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
ECLASS | ECLASS-11.0: 27242220 ECLASS-12.0: 27242220 ECLASS-13.0: 27242220 |
ETIM | ETIM 9.0: EC000237 |