PHOENIX CONTACT 2961749
PHOENIX CONTACTNot available

DEK-OV- 12DC/ 24DC/ 10 - Solid-state relay terminal block

Power solid-state relay terminal block, input: DC voltage, output: DC voltage, input voltage: 12 V DC
Product Code: 2961749
Partner cod.: 2961749
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesGeneral: The housing is open on one side. The appropriate cover is D-DEK 1,5 GN (2716949).
Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.
Product propertiesProduct type: Solid-state relay module
Product family: DEK
Application: Output function
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics: Standards/regulations
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesTest voltage (Input/output): 2.5 kV AC (Input/output)
Input dataNominal input voltage UN: 12 VDC
Input voltage range in reference to UN: 0.8 ... 1.2
Input voltage range: 9.6 VDC ... 14.4 VDC
Switching threshold "0" signal in reference to UN: ≤ 0.4
Switching threshold "1" signal in reference to UN: ≥ 0.8
Typical input current at UN: 4.7 mA
Typical response time: 250 µs
Typical turn-off time: 800 µs
Operating voltage display: Yellow LED
Protective circuit: Reverse polarity protection
Surge protection
Transmission frequency: 100 Hz
Output dataContact switching type: 1 N/O contact
Design of digital output: electronic
Output voltage range: 5 VDC ... 30 VDC
Limiting continuous current: 10 A (see derating curve)
Surge current: 100 A (t=20ms)
Voltage drop at max. limiting continuous current: < 50 mV
Output circuit: 3-conductor, ground-referenced
Protective circuit: Reverse polarity protection
Surge protection
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 14
Tightening torque: 0.5 Nm
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 56 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -20°C ... 60°C
Ambient temperature (storage/transport): -20°C ... 70°C
Standards and regulationsStandards/regulations
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371604
ECLASS-12.0: 27371604
ECLASS-13.0: 27371604
ETIMETIM 9.0: EC001504
UNSPSCUNSPSC 21.0: 39122300
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Data_sheet_03411.pdf

Manufacturer_declaration_00542.pdf

Manufacturer_declaration_03020.pdf

Manufacturer_declaration_04136.pdf

Manufacturer_declaration_04137.pdf

Manufacturer_declaration_16796.pdf

Package_slip_00896.pdf

Product_information_00033.pdf

Product_information_00806.pdf

Technical_drawing_41395.pdf