Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2963996
PHOENIX CONTACTNot available

PSR-SPP-24UC/ESAM4/8X1/1X2 - Safety relays

Safety relay for emergency stop and safety door monitoring up to SIL3 or Cat.4, PLe in accordance with ENISO13849, single- or two-channel operation, 8enabling current paths, US=24VDC, pluggable Push-in terminal block
Product Code: 2963996
Partner cod.: 2963996
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Safety relays
Product family: PSRclassic
Application: Emergency stop
Safety door
Mechanical service life: approx. 107 cycles
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN61810-3
Electrical propertiesMaximum power dissipation for nominal condition: 31.7 W (US=26.4V, IL²=144A², PTotalmax=2.9W+28.8W)
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 V
Rated surge voltage/insulation: Basic insulation 4kV:
between all current paths and housing
Safe isolation, reinforced insulation 6kV:
between A1/A2 and 63/64, 73/74, 83/84
between S10/S11/S12/S33/S34/S35 and 63/64, 73/74, 83/84
between 63/64, 73/74, 83/84 among one another
Input dataGeneral
Rated control circuit supply voltage US: 24 VDC -15% / +10%
Power consumption at US: typ. 2.4 W (DC)
Rated control supply current IS: typ. 100 mA DC (at US)
Inrush current: 3.5 A (Δt=2ms at Us)
max. 150 mA (Δt=1ms, with Us/Ix at S10)
max. 200 mA (Δt=1ms, with Us/Ix at S12)
max. -180 mA (Δt=1ms, with Us/Ix at S22)
< 10 mA (with Us/Ix to S34)
< 10 mA (with Us/Ix to S35)
Current consumption: 50 mA (with Us/Ix to S10)
50 mA (with Us/Ix to S12)
-50 mA (with Us/Ix to S22)
0 mA (with Us/Ix to S34)
1 mA (with Us/Ix to S35)
Voltage at input/start and feedback circuit: 24 VDC -15% / +10%
Filter time: 2 ms (at A1 in the event of voltage dips at Us)
max. 1.5 ms (at S10, S12; test pulse width)
7.5 ms (at S10, S12; test pulse rate)
Test pulse rate=5xTest pulse width
Typical response time: < 120 ms (automatic start)
< 140 ms (manual start)
Typ. starting time with Us: < 200 ms (when controlled via A1)
Typical release time: < 20 ms (when controlled via S11/S12 and S21/S22)
< 50 ms (when controlled via A1)
Concurrence: ∞
Recovery time: < 500 ms (following demand of the safety function)
< 1 s (Boot time)
Maximum switching frequency: 0.5 Hz
Protective circuit: Surge protection; Suppressor diode
Max. permissible overall conductor resistance: 11 Ω (Input sensor circuit S10,S12,S22)
50 Ω (S34,S35 start circuit input)
Operating voltage display: 1 x green LED
Status display: 2 x green LEDs
Output dataContact switching type: 8 enabling current paths
1 signaling current path
Contact material: AgSnO2
Maximum switching voltage: 250 VAC
Minimum switching voltage: 5 V AC/DC
Limiting continuous current: 6 A
Maximum inrush current: 6 A
Inrush current, minimum: 10 mA
Sq. Total current: 144 A2 (Enabling current paths)
36 A2 (Signaling current path)
Switching capacity min.: 50 mW
Switching capacity in accordance with IEC 60947-5-1: 5 A (DC13)
3 A (AC15)
0.5 A (AC15)
Output fuse: 10 A gL/gG (Enabling current paths)
6 A gL/gG (Signaling current path)
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG: 24 ... 16
Stripping length: 8 mm
DimensionsWidth: 45 mm
Height: 112 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 0
Safety data: ENISO13849
Category: 4
Performance level (PL): e (3ADC13; 3AAC15; 8760switching cycles/year)
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 3
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -20°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 70°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Shock: 15g
Vibration (operation): 10Hz...150Hz, 2g
ApprovalsCE
Certificate: CE-compliant
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: DINEN60947-1
MountingMounting type: DIN rail mounting
Assembly instructions: See derating curve
Mounting position: vertical or horizontal
Connection method: Push-in connection
Technical Specs
ECLASSECLASS-11.0: 27371819
ECLASS-13.0: 27371819
ECLASS-12.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00317.pdf

Approvals_00835.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Data_sheet_03965.pdf

Data_sheet_03964.pdf

Manufacturer_declaration_00585.pdf

Manufacturer_declaration_02369.pdf

Manufacturer_declaration_05474.pdf

Manufacturer_declaration_16849.pdf

Package_slip_01901.pdf

Package_slip_01902.pdf

Technical_drawing_41444.pdf