Industrial Automation
OPT-60DC/ 24DC/ 2 - Miniature solid-state relay


Product properties | Product type: Single solid-state relay Operating mode: 100% operating factor Insulation characteristics Insulation: Basic insulation Insulation characteristics: Standards/regulations Insulation: Basic insulation Overvoltage category: III Pollution degree: 2 |
Electrical properties | Maximum power dissipation for nominal condition: 0.18 W Test voltage (Input/output): 2.5 kV (50ÃHz, 1Ãmin., input/output) |
Input data | Nominal input voltage UN: 60 VÃDC Input voltage range in reference to UN: 0.8 ... 1.2 Input voltage range: 48 VÃDC ... 72 VÃDC Switching threshold "0" signal, voltage: ââ°¤ 20 V Switching threshold "1" signal voltage: ââ°¥ 35 V Typical input current at UN: 3 mA Typical response time: 40 õs (at UN) Typical turn-off time: 500 õs (at UN) Transmission frequency: 300 Hz |
Output data | Contact switching type: 1 N/O contact Design of digital output: electronic Output voltage range: 3 VÃDC ... 33 VÃDC Limiting continuous current: 3 A (see derating curve) Maximum inrush current: 15 A (10 ms) Voltage drop at max. limiting continuous current: ââ°¤ 150 mV Output circuit: 2-conductor, floating Protective circuit: Reverse polarity protection; Polarity protection diode Surge protection |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/260a0c446066a14fa55788300101ccb8/-S204x204-FJPG Width: 5 mm Height: 28 mm Depth: 15 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection: RT III Ambient temperature (operation): -25°C ... 60°C Ambient temperature (storage/transport): -25°C ... 70°C |
Approvals | Corrosive gas test Identification: ISA-S71.04. G3 Harsh Group ENÃ60068-2-60 |
Standards and regulations | Standards/regulations Standards/regulations: IEC 60664 ENÃ50178 |
Mounting | Assembly instructions: in rows with zero spacing Mounting position: any |