Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2967109
PHOENIX CONTACTNot available

PLC-RSC- 24DC/ 1- 1/ACT - Relay Module

PLC-INTERFACE for output functions, consisting of PLC-BSC.../ACT basic terminal block with screw connection and plug-in miniature relay with power contact, for mounting on DIN rail NS 35/7,5, 2 N/O contacts (1-1), input voltage 24 V DC
Product Code: 2967109
Partner cod.: 2967109
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Relay Module
Product family: PLC-INTERFACE
Application: Output function
Operating mode: 100% operating factor
Mechanical service life: 3x 107 cycles
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.43 W
Test voltage (Winding/contact): 4 kVrms (50Hz, 1min.)
Test voltage (): 1 kVrms (50Hz, 1min.)
Test voltage (N/O contact / N/O contact): 2.5 kVrms (50Hz, 1min.)
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VAC
Rated surge voltage: 4 kV (Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths)
Input dataCoil side
Nominal input voltage UN: 24 VDC
Input voltage range: 20.2 VDC ... 33.6 VDC (20°C)
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 18 mA
Input power dissipation for UN: 0.43 W
Typical response time: 8 ms
Typical release time: 10 ms
Protective circuit: Reverse polarity protection; Polarity protection diode
Freewheeling diode; Freewheeling diode
Operating voltage display: Yellow LED
Output dataSwitching
Contact switching type: 2 N/O contacts
Type of switch contact: Single contact
Contact material: AgNi
Maximum switching voltage: 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage: 5 V (10mA)
Limiting continuous current: 6 A
Maximum inrush current: 25 A (20ms)
Min. switching current: 10 mA (5V)
Interrupting rating (ohmic load) max.: 144 W (24VDC)
96 W (48VDC)
60 W (at 60 V DC)
44 W (at 110 V DC)
60 W (at 220 V DC)
1500 VA (250VAC)
Switching capacity min.: 50 mW
Switching capacity: 2 A (24V (DC13))
0.2 A (250V (DC-13))
3 A (24V (AC15))
3 A (120V (AC15))
3 A (250V (AC15))
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.6 Nm ... 0.8 Nm
DimensionsWidth: 14 mm
Height: 80 mm
Depth: 94 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection (Relay): RT III
Degree of protection (Relay base): IP20
Degree of protection (Installation location): ≤ IP54
Ambient temperature (operation): -40°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
Standards and regulationsStandards/regulations
Standards/regulations: IEC 61810-1
Air clearances and creepage distances between the power circuits
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371601
ECLASS-12.0: 27371601
ECLASS-13.0: 27371601
ETIMETIM 9.0: EC001437
UNSPSCUNSPSC 21.0: 39122300
Description
PLC-INTERFACE for output functions, consisting of PLC-BSC.../ACT basic terminal block with screw connection and plug-in miniature relay with power contact, for mounting on DIN rail NS 35/7,5, 2 N/O contacts (1-1), input voltage 24 V DC
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00002.pdf

Application_note_00006.pdf

Application_note_00148.pdf

Approvals_00240.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01883.pdf

Manufacturer_declaration_03393.pdf

Manufacturer_declaration_03394.pdf

Manufacturer_declaration_03599.pdf

Manufacturer_declaration_16932.pdf

Package_slip_01742.pdf

Product_information_00033.pdf

Product_information_00521.pdf

Technical_drawing_41542.pdf