Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2981512
PHOENIX CONTACTNot available

PSR-SCP- 24DC/URD3/4X1/2X2 - Extension module

1-channel contact extension with TBUS interface, 4N/O contacts, 1N/C contact, 1 confirmation current path, adjustable dropout delay of 0.5...30 s, Cat.3, PL e in accordance with ENISO13849, plug-in screw terminal blocks, width: 22.5mm
Product Code: 2981512
Partner cod.: 2981512
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Safety relays
Product family: PSRclassic
Application: Extension module
Mechanical service life: approx. 107 cycles
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN61810-3
Electrical propertiesMaximum power dissipation for nominal condition: 2.02 W
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 V
Rated surge voltage/insulation: 4 kV / basic isolation (safe isolation, reinforced insulation and 6 kV between input circuit/N/C contacts and enabling current paths).
Input dataGeneral
Nominal input voltage UN: 24 VDC
Input voltage range in reference to UN: 0.85 ... 1.1
Typical input current at UN: 84 mA
Typical response time: 20 ms
Typical release time range: 0.5 s ... 38 s ±20% (BG rating to max. 30 s)
Recovery time: 1 s
Protective circuit: Surge protection; Suppressor diode
Fuse; PTC resistor
Operating voltage display: Green LED
Status display: Green LED
Output dataContact switching type: 4 delayed enabling current paths
1 delayed signaling current path
1 delayed confirmation current path
Contact material: AgSnO2
Maximum switching voltage: 250 V AC/DC
Minimum switching voltage: 15 V AC/DC
Limiting continuous current: 6 A (N/O contact)
3 A (N/C contact)
Maximum inrush current: 6 A (N/O contact)
3 A (N/C contact)
Inrush current, minimum: 25 mA
Sq. Total current: 50 A2 (ITH2 = I12 + I22 + I32 + I42)
Interrupting rating (ohmic load) max.: 114 W (24 V DC, τ = 0 ms, N/C contact 65/66: 72 W)
288 W (48 V DC, τ = 0 ms, N/C contact 65/66: 144 W)
77 W (110 V DC, τ = 0 ms)
88 W (220 V DC, τ = 0 ms)
1500 VA (250 V AC, τ = 0 ms, N/C contact 65/66: 750 VA)
Maximum interrupting rating (inductive load): 48 W (24VDC, τ=40ms)
40 W (48 V DC, τ = 40 ms)
35 W (110 V DC, τ = 40 ms)
33 W (220 V DC, τ = 40 ms)
Switching capacity min.: 0.4 W
Switching capacity (360/h cycles): 6 A (24VDC)
5 A (230 V AC)
Switching capacity (3600/h cycles): 3 A (24V (DC13))
3 A (230 V (AC15))
Output fuse: 10 A gL/gG NEOZED (N/O contact)
4 A gL/gG NEOZED (N/C contact)
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 12
Stripping length: 7 mm
Screw thread: M3
DimensionsWidth: 22.5 mm
Height: 99 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 1
Safety data: ENISO13849
Category: 3 (In conjunction with suitable evaluating device)
Performance level (PL): e (In conjunction with suitable evaluating device)
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3 (In conjunction with suitable evaluating device)
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 3 (In conjunction with suitable evaluating device)
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3 (In conjunction with suitable evaluating device)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -20°C ... 55°C
Ambient temperature (storage/transport): -40°C ... 70°C
Maximum altitude: max. 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60664-1
MountingMounting type: DIN rail mounting
Mounting position: any
Connection method: Screw connection
Technical Specs
ECLASSECLASS-11.0: 27371819
ECLASS-12.0: 27371819
ECLASS-13.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Approvals_01812.pdf

Approvals_01813.pdf

Certification_00173.pdf

Certification_00340.pdf

Data_sheet_03981.pdf

Manufacturer_declaration_00584.pdf

Manufacturer_declaration_02367.pdf

Manufacturer_declaration_17029.pdf

Package_slip_01886.pdf

Technical_drawing_41670.pdf