PHOENIX CONTACT 2982702
PHOENIX CONTACT 2982702
PHOENIX CONTACTAvailable

PLC-OSC- 24DC/ 24DC/ 10/R - Solid-state relay module

PLC-INTERFACE with checkback contact, consisting of basic terminal block with screw connection and integrated miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24VDC, output: 3 ... 33VDC/10A
Product Code: 2982702
Partner cod.: 2982702
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesGeneral: The PLC-ATP partition plate must be installed for voltages greater than 250V (L1, L2, L3) between identical terminal blocks on adjacent modules.
The PLC-ATP separating plate should be installed for safe isolation between adjacent modules
Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch.
The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.
At least one functional insulation against adjacent modules is complied with in the support rail direction.
If the application has higher requirements on the insulation (basic or reinforced insulation), then these must be realized through suitable measures (e.g., partition plates).
Do not use to separate SELV / PELV circuits from other circuits, because safe isolation is not guaranteed.
Product propertiesProduct type: Solid-state relay module
Product family: PLC-INTERFACE
Application: With integrated solid-state relay
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation: Basic insulation
Overvoltage category: II
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.07 W
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 50 VDC
Rated surge voltage: 0.5 kV
Input dataRated actuating voltage UC: 24 VDC
Rated actuating current IC: 3.5 mA
Switching threshold "0" signal in reference to UN: < 0.4
Switching threshold "1" signal in reference to UN: > 0.8
Typical response time: 100 µs
Typical turn-off time: 500 µs
Operating voltage display: Yellow LED
Protective circuit: Reverse polarity protection; Polarity protection diode
Surge protection
Surge voltage protection: > 33 V
Transmission frequency: 100 Hz
Output dataDesignation: DC voltage output
Alarm output
Contact switching type: 1 N/O contact
Design of digital output: electronic
Contact connection type: Power contact
Output voltage range: 8 VDC ... 33 VDC
3 VDC ... 33 VDC
Limiting continuous current: 10 A (see derating curve)
100 mA
Quiescent current: 5.2 mA
Voltage drop at max. limiting continuous current: < 50 mV
< 1.2 V
Output circuit: 3-conductor, ground-referenced
2-conductor, floating
Protective circuit: Inverse diode
Surge protection
Reverse polarity protection; Polarity protection diode
Surge protection; Suppressor diode
Surge voltage protection: > 33 V
Error indication: Red LED
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing))
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 86 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Degree of protection (Installation location): IP54 (Installation location)
Ambient temperature (operation): -25°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371604
ECLASS-12.0: 27371604
ECLASS-13.0: 27371604
ETIMETIM 9.0: EC001504
UNSPSCUNSPSC 21.0: 39122300
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_00240.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01883.pdf

Manufacturer_declaration_00971.pdf

Manufacturer_declaration_01805.pdf

Manufacturer_declaration_04163.pdf

Manufacturer_declaration_04164.pdf

Manufacturer_declaration_17052.pdf

Package_slip_01741.pdf

Product_information_00033.pdf

Product_information_00841.pdf

Technical_drawing_41699.pdf