PLC-BSC- 24UC/ 1/ACT - Relay base

6.2 mm PLC basic terminal block for output functions with screw connection, without relay or solid-state relay, for mounting on DIN rail NS 35/7,5, with load return line connection (BB), 1 N/O contact, input voltage 24 V AC/DC
Product Code: 2982799
Partner cod.: 2982799
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Relay socket
Product family: PLC-INTERFACE
Application: Output function
Operating mode: 100% operating factor
Compatible components: Miniature relay, REL-MR-24DC/21, REL-MR-24DC/21AU; miniature optocoupler, OPT-24DC/24DC/2, OPT-24DC/48DC/100, OPT-24DC/230AC/1
Insulation characteristics
Pollution degree: 3
Input dataNominal input voltage UN: 24 V AC/DC
Protective circuit: Bridge rectifier
Relay assembly
Rated control circuit supply voltage US: 24 V AC/DC
Voltage range with reference to US: 0.8 ... 1.2
Typical input current at UN: 15.6 mA (50Hz)
8.5 mA (60Hz)
Typical response time: 5 ms
Typical release time: 30 ms
Operating voltage display: Yellow LED
Protective circuit: Bridge rectifier; Bridge rectifier
Optocoupler assembly
Rated control circuit supply voltage US: 24 V AC/DC
Voltage range with reference to US: 0.8 ... 1.2
Typical input current at UN: 15 mA (50Hz)
8.3 mA (60Hz)
Typical response time: 10 ms
Typical release time: 20 ms
Operating voltage display: Yellow LED
Protective circuit: Bridge rectifier; Bridge rectifier
Output dataCompatible components: Miniature relay, REL-MR-24DC/21, REL-MR-24DC/21AU; miniature optocoupler, OPT-24DC/24DC/2, OPT-24DC/48DC/100, OPT-24DC/230AC/1
Maximum switching voltage: 33 VDC
48 VDC
253 VAC
Minimum switching voltage: 3 VDC
24 VAC
Limiting continuous current: 3 A (see derating curve)
100 mA
0.75 A (see derating curve)
Voltage drop at max. limiting continuous current: ≤ 150 mV
≤ 1 V
≤ 1 V
Output circuit: 2-conductor, floating
2-conductor floating, zero voltage switch
Protective circuit: Reverse polarity protection Parallel polarity protection diode
Surge protection
Reverse polarity protection Parallel polarity protection diode
Surge protection
RCV circuit
Leakage current: ≤ 1 mA
Max. load value: 4.5 A2s (tp = 10ms, at 25°C)
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing))
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 94 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -20°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371603
ECLASS-12.0: 27371603
ECLASS-13.0: 27371603
ETIMETIM 9.0: EC001456
UNSPSCUNSPSC 21.0: 39122300
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Application_note_00002.pdf

Application_note_00148.pdf

Approvals_00240.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Manufacturer_declaration_03373.pdf

Manufacturer_declaration_03374.pdf

Manufacturer_declaration_03684.pdf

Manufacturer_declaration_17057.pdf

Package_slip_01741.pdf

Product_information_00033.pdf

Product_information_00546.pdf

Technical_drawing_41704.pdf