PHOENIX CONTACT 2985688
PHOENIX CONTACTNot available

IB IL 24 PSDI 8-PAC - Safety module

Safety-related digital input module, IP20 protection, for the SafetyBridge, INTERBUS-Safety, and PROFIsafe system. The module has 4 safe digital inputs for two-channel assignment or 8 safe digital inputs for single-channel assignment.
Product Code: 2985688
Partner cod.: 2985688
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/2182c65be3908e489150116208cdf69e/-S204x204-FJPG
Width: 48.8 mm
Height: 119.8 mm
Depth: 71.5 mm
Note on dimensions: Housing dimensions
InterfacesInline local bus
No. of channels: 2
Connection method: Inline data jumper
Transmission speed: 500 kbps / 2 Mbps (can be switched)
System propertiesModule
ID code (dec.): 163
ID code (hex): A3
Length code (hex): 04
Length code (dec): 04
Process data channel: 8 Byte
Input address area: 8 Byte ((Operating mode: SafetyBridge))
Output address area: 8 Byte ((Operating mode: SafetyBridge))
Register length: 8 Byte
Required parameter data: 1 Byte ((Operating mode: SafetyBridge))
Required configuration data: 5 Byte ((Operating mode: SafetyBridge))
Input dataDigital
Input name: Digital inputs
Description of the input: IEC 61131-2 type 3
Number of inputs: 4 (for 2-channel assignment)
8 (for 1-channel assignment)
Cable length: max. 200 m (200 m from the clock output to the safe input (total based on forward and return path))
Connection method: Spring-cage connection
Connection technology: 2-, 3-, 4-conductor
Input voltage: 24 VDC (via clock outputs UT1 and UT2 or external supply)
Input voltage range: -3 VDC ... 30 VDC
Input voltage range "0" signal: -3 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Typical input current per channel: 4.2 mA (at 24V)
Typical response time: See technical data
Product propertiesType: modular
Product type: I/O component
Product family: Inline
Application: Functional safety
Electrical propertiesMaximum power dissipation for nominal condition: 24.12 W
Transmission medium: Copper
Potentials: Communications power (U
Supply voltage: 7.5 VDC (see safety data)
Current draw: max. 180 mA
Potentials: Main circuit supply (U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 825 mA (see safety data)
typ. 25 mA (plus current consumption of the inputs when supplied via the clock outputs, plus current consumption of the connected initiators when via through the clock outputs)
Supply: Module electronics
Supply voltage: 24 VDC (via voltage jumper)
Supply voltage range: 19.2 VDC ... 30 VDC
Electrical isolation/isolation of the voltage ranges
Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics): 500 VAC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics): 500 VAC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O): 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: Inline connector
pluggable: yes
Conductor connection
Connection method: Spring-cage connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Inline connector
Connection method: Spring-cage connection
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 55°C
Degree of protection: IP20
Air pressure (operation): 80 kPa ... 108 kPa (up to 2000m above sea level)
Air pressure (storage/transport): 66 kPa ... 108 kPa (up to 3500m above sea level)
Ambient temperature (storage/transport): -25°C ... 70°C
Permissible humidity (operation): 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Permissible humidity (storage/transport): 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27242604
ECLASS-12.0: 27242604
ECLASS-13.0: 27242604
ETIMETIM 9.0: EC001599
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00104.pdf

Application_note_00226.pdf

Application_note_00111.pdf

Application_note_00183.pdf

Application_note_00059.pdf

Approvals_00168.pdf

Approvals_00523.pdf

Approvals_00833.pdf

Approvals_01152.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Approvals_01358.pdf

Certification_00182.pdf

Certification_00369.pdf

Manual_00235.pdf

Manufacturer_declaration_00963.pdf

Manufacturer_declaration_02135.pdf

Manufacturer_declaration_17060.pdf

Package_slip_01304.pdf

Quick_start_guide_00025.pdf

Quick_start_guide_00016.pdf

Quick_start_guide_00045.pdf

Quick_start_guide_00046.pdf

Technical_drawing_41707.pdf

Various_00038.pdf