UWV 25 - Panel feed-through terminal block


Product properties | Product type: Panel feed-through terminal block Product family: UWV 25 Number of positions: 1 Pitch: 15.1 mm Number of connections: 2 Number of rows: 1 Number of potentials: 1 Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Electrical properties | Nominal current IN: 101 A Nominal voltage UN: 630 V Degree of pollution: 3 Rated voltage (III/3): 630 V Rated surge voltage (III/3): 6 kV |
Connection data | Connection technology Connector system: UW 25 Nominal cross section: 25 mm² Conductor connection exterior Connection method: Screw connection with tension sleeve Connection direction of the conductor to plug-in direction: -90° Conductor cross section rigid: 6 mm² ... 35 mm² Conductor cross section flexible: 10 mm² ... 25 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 4 mm² ... 25 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 4 mm² ... 25 mm² 2 conductors with same cross section, solid: 2.5 mm² ... 10 mm² 2 conductors with same cross section, flexible: 4 mm² ... 10 mm² 2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 2.5 mm² ... 10 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 2.5 mm² ... 10 mm² Internal cylindrical gage: B7 Stripping length: 19 mm Tightening torque: 4 Nm ... 4.5 Nm Conductor connection interior Connection method: Screw connection with tension sleeve Connection direction of the conductor to plug-in direction: 0° Conductor cross section rigid: 6 mm² ... 35 mm² Conductor cross section flexible: 10 mm² ... 25 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 4 mm² ... 25 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 4 mm² ... 25 mm² 2 conductors with same cross section, solid: 2.5 mm² ... 10 mm² 2 conductors with same cross section, flexible: 4 mm² ... 10 mm² 2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 2.5 mm² ... 10 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 2.5 mm² ... 10 mm² Internal cylindrical gage: B7 Stripping length: 19 mm Tightening torque: 4 Nm ... 4.5 Nm |
Mounting | Plate thickness: 1 mm ... 6 mm |
Material specifications | Material data - contact Note: WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 Contact material: Cu alloy Surface characteristics: tin-plated Material data - housing Color (Housing): gray (7042) Insulating material: PA Insulating material group: I CTI according to IEC 60112: 600 Flammability rating according to UL 94: V0 Glow wire flammability index GWFI according to ENÃ60695-2-12: 850 Glow wire ignition temperature GWIT according to ENÃ60695-2-13: 775 Temperature for the ball pressure test according to ENÃ60695-10-2: 125°C |
Notes | Safety note Safety note: â⬢ Only electrically qualified personnel may install and operate the product. To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering. â⬢ Observe the technical data provided here and refer to the documents listed under ââ¬Ã Downloadsââ¬. The download area contains important information, such as installation notes, technical drawings, and 3D data. â⬢ The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection. |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e840d33717330747ad0c7b5d4b264f71/-S204x204-FJPG Pitch: 15.1 mm Width [w]: 15.1 mm External dimensions Width [w]: 15.1 mm Height [h1]: 54.8 mm Length [l1]: 45.5 mm Internal dimensions Width [w]: 15.1 mm Height [h2]: 45 mm Length [l2]: 33.3 mm |
Mechanical tests | Test for conductor damage and slackening Specification: IEC 60947-7-1:2009-04 Result: Test passed Pull-out test Specification: IEC 60947-7-1:2009-04 Conductor cross section/conductor type/tractive force setpoint/actual value: 6 mm² / solid / > 80 N 10 mm² / flexible / > 90 N 35 mm² / stranded / > 190 N 25 mm² / flexible / > 135 N |
Electrical tests | Temperature-rise test Specification: IEC 60947-7-1:2009-04 Requirement temperature-rise test: Increase in temperature ââ°¤Ã45ÃK Short-time withstand current Specification: IEC 60947-7-1:2009-04 Air clearances and creepage distances | 1. Insulation coordination Application: without spacer plate Specification: IEC 60947-7-1:2009-04 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 630 V Rated surge voltage (III/3): 6 kV minimum clearance value - non-homogenous field (III/3): 5.5 mm minimum creepage distance (III/3): 8 mm Air clearances and creepage distances | 2. Insulation coordination Application: with spacer plate Specification: IEC 60947-7-1:2009-04 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 800 V Rated surge voltage (III/3): 8 kV minimum clearance value - non-homogenous field (III/3): 8 mm minimum creepage distance (III/3): 10 mm |
Environmental and real-life conditions | Glow-wire test Specification: IEC 60695-2-11:2000-10 Temperature: 960°C Time of exposure: 30 s Ambient conditions Ambient temperature (operation): -40°C ... 100°C (Depending on the current carrying capacity/derating curve) Ambient temperature (storage/transport): -40°C ... 70°C Relative humidity (storage/transport): 30 % ... 70 % Ambient temperature (assembly): -5°C ... 100°C |
Packaging specifications | Type of packaging: packed in cardboard |