PHOENIX CONTACT 3246560
PHOENIX CONTACTNot available

HDFK 50-VP-IB/IB - Panel feed-through terminal block

Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Cable lug connection, number of positions: 1, load current: 150 A, cross section: 16 mm2-50 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 18.8 mm
Product Code: 3246560
Partner cod.: 3246560
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Product propertiesProduct type: Panel feed-through terminal block
Product family: HDFK 50-VP
Number of positions: 1
Pitch: 18.8 mm
Number of connections: 2
Number of potentials: 1
Electrical propertiesNominal current IN: 150 A
Nominal voltage UN: 690 V
Degree of pollution: 3
Rated voltage (III/3): 690 V
Rated surge voltage (III/3): 8 kV
Connection dataConnection technology
Connector system: HDFK 50
Nominal cross section: 50 mm²
Conductor connection exterior
Connection method: Screw connection with tension sleeve
Connection direction of the conductor to plug-in direction: 0°
Conductor cross section rigid: 16 mm² ... 50 mm²
Conductor cross section flexible: 16 mm² ... 50 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 10 mm² ... 50 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 10 mm² ... 50 mm²
2 conductors with same cross section, solid: 6 mm² ... 16 mm²
2 conductors with same cross section, flexible: 10 mm² ... 16 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 6 mm² ... 16 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 6 mm² ... 10 mm²
Internal cylindrical gage: B10
Stripping length: 24 mm
Tightening torque: 6 Nm ... 8 Nm
Conductor connection interior
Connection method: Cable lug connection
Connection direction of the conductor to plug-in direction: 0°
Material specificationsMaterial data - contact
Note: WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Contact material: Cu alloy
Surface characteristics: tin-plated
Material data - housing
Color (Housing): gray (7042)
Insulating material: PA
Insulating material group: I
CTI according to IEC 60112: 600
Flammability rating according to UL 94: V0
Glow wire flammability index GWFI according to EN60695-2-12: 850
Glow wire ignition temperature GWIT according to EN60695-2-13: 775
Temperature for the ball pressure test according to EN60695-10-2: 125°C
NotesSafety note
Safety note: • Only electrically qualified personnel may install and operate the product.
To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering.
• Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data.
• The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection.
• To maintain the nominal voltage, align the cable lugs straight and centered, and cast the terminals on the inside.
 There is no electrical contact to the housing. Make sure that protective grounding is provided for green/yellow color variants and articles marked with PE.
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e840d33717330747ad0c7b5d4b264f71/-S204x204-FJPG
Pitch: 18.8 mm
Width [w]: 18.8 mm
External dimensions
Height [h1]: 54 mm
Length [l1]: 43 mm
Internal dimensions
Height [h2]: 37 mm
Length [l2]: 35 mm
Electrical testsAir clearances and creepage distances | 1. Insulation coordination
Application: Metal wall 4.5mm...6.0mm
Internal part molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 690 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 8 mm
Air clearances and creepage distances | 2. Insulation coordination
Application: Metal panel 2.0mm...4.5mm
Internal part molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 800 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 10 mm
Air clearances and creepage distances | 3. Insulation coordination
Application: Metal panel 1.0mm...2.0mm
Internal part molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 1000 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 12.5 mm
Air clearances and creepage distances | 4. Insulation coordination
Application: Plastic panel 1.0...6.0mm
Internal part molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 1000 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 12.5 mm
Air clearances and creepage distances | 5. Insulation coordination
Application: Metal wall 1.0mm...6.0mm
Internal part not molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 250 V
Rated surge voltage (III/3): 4 kV
minimum clearance value - non-homogenous field (III/3): 3 mm
minimum creepage distance (III/3): 3.2 mm
Air clearances and creepage distances | 6. Insulation coordination
Application: Plastic panel 1.0...6.0mm
Internal part not molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 250 V
Rated surge voltage (III/3): 4 kV
minimum clearance value - non-homogenous field (III/3): 3 mm
minimum creepage distance (III/3): 3.2 mm
Packaging specificationsType of packaging: packed in cardboard
Technical Specs
ECLASSECLASS-11.0: 27141134
ECLASS-13.0: 27141134
ECLASS-12.0: 27141134
ETIMETIM 8.0: EC001283
UNSPSCUNSPSC 21.0: 39121400