Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 5603260
PHOENIX CONTACT 5603260
PHOENIX CONTACTAvailable

PLC-OSC- 24DC/ 24DC/ 2/C1D2 - Optocoupler

PLC-INTERFACE, consisting of DIN rail-mountable basic terminal block with screw connection and plug-in miniature solid-state relay, input: 24VDC, output: 3 ... 33VDC/3A, UL/cUL: approved for use in Ex Zone Class I, Div. 2
Product Code: 5603260
Partner cod.: 5603260
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Solid-state relay module
Product family: PLC-INTERFACE
Application: Class I, Division 2
potentially explosive areas
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics: Standards/regulations
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.2 W
Test voltage (Input/output): 2.5 kV (50Hz, 1min., input/output)
Input dataNominal input voltage UN: 24 VDC
Input voltage range in reference to UN: 0.8 ... 1.2
Input voltage range: 19.2 VDC ... 28.8 VDC
Switching threshold "0" signal in reference to UN: ≤ 0.4
Switching threshold "1" signal in reference to UN: ≥ 0.8
Typical input current at UN: 8.5 mA
Typical response time: 20 µs (at UN)
Typical turn-off time: 300 µs (at UN)
Operating voltage display: Yellow LED
Protective circuit: Reverse polarity protection; Polarity protection diode
Freewheeling diode; Freewheeling diode
Transmission frequency: 300 Hz
Output dataContact switching type: 1 N/O contact
Design of digital output: electronic
Output voltage range: 3 VDC ... 33 VDC
Limiting continuous current: 3 A
Maximum inrush current: 15 A (10 ms)
Voltage drop at max. limiting continuous current: ≤ 200 mV
Output circuit: 2-conductor, floating
Protective circuit: Reverse polarity protection; Polarity protection diode
Surge protection
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.6 Nm ... 0.8 Nm
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 94 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -20°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCE
Certificate: CE-compliant
UL, USA
Identification: Class I, Zone 2, AEx nA nC IIC T6
UL, USA/Canada
Identification: Class I, Div. 2, Groups A, B, C, D
UL, Canada
Identification: Class I, Zone 2, Ex nA nC IIC Gc T6 X
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
Standards and regulationsStandards/regulations
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371604
ECLASS-12.0: 27371604
ECLASS-13.0: 27371604
ETIMETIM 9.0: EC001504
UNSPSCUNSPSC 21.0: 39122300
Description
PLC-INTERFACE, consisting of DIN rail-mountable basic terminal block with screw connection and plug-in miniature solid-state relay, input: 24 V DC, output: 3 ... 33 V DC/3 A, UL/cUL: approved for use in Ex Zone Class I, Div. 2