Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

ROCKWELL AUTOMATION 140M-C2E-A40
ROCKWELL AUTOMATION 140M-C2E-A40
ROCKWELL AUTOMATIONAvailable

Motor Protection Circuit-Breaker

Product Code: 140M-C2E-A40
Partner cod.: 140M-C2E-A40
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Tecnichal data
With integrated auxiliary switchNo
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, AC100 kA
Rated operation power at AC-3, 230 V0.06 kW
Rated operating voltage230 A
Type of control elementTurn button
Overload release current setting0.25 A
Type of electrical connection of main circuitScrew connection
Magnetic release current per IEC5.2 A
Rated operational current (Ie) per IEC0.4 A
Magnetic trip current5.2 A
Short circuit current (Type 2 coordination), max-inv65 kA @ 480V
Current range0.25...0.40 A
Ultimate short circuit breaking capacity (Icu) per IEC100 kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC100 kA @ 690V
Hp rating, max0.25 Hp @ 575V, 3-phase
Rated operating voltage, max690V per IEC, SEV, VDE0660
Electrical life cycle(Ie max.) 100000 operations
Short circuit current for combination motor controller with 100-K contactor, max-inv65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for combination motor controller with 100-C contactor, max-inv65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv65 kA @ 480Y/277V, UL 508-Type E
Switching of standard motors per IEC0.18 kW @ 690V, 3-phase
KW rating, max0.18 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IECNo back-up fuse required @ 690V
Short circuit current for group motor installation with 100-K contactor, max-inv65 kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-K contactor, max-inv65 kA @ 480V, UL 508-manual motor controller
Short circuit current for group motor installation with 100-C contactor, max-inv65 kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max-inv65 kA @ 480V, UL 508-manual motor controller
Rated thermal current0.1...32 A @ 60 °C ambient temperature (Ith)-inv
Short circuit current for tap conductor protection, max65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max65 kA @ 480V/277V per UL 508-self-protected (Type E)
Fuse or circuit breaker per NEC, max450 A, UL 508-manual motor controller
Fuse or circuit breaker rating per NEC, max450 A, UL 508-manual motor controller with 100-C contactor
Short circuit current for group motor installation, max65 kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max65 kA @ 480V, UL 508-manual motor controller
Magnetic release currentFixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %)
Number of poles3
With thermal protectionYes
Phase failure sensitiveYes
Switch off techniqueThermomagnetic
Switching frequency, max25 ops/h
Trip class10
Rated frequency50/60 Hz
Rated supply current0.1 A
Total power loss (Pv) for circuit breaker at rated load operating temperature-inv6 W
Phase loss protectionDifferential release
Fuse or circuit breaker rating with 100-K contactor per NEC, max450 A, UL 508-manual motor controller
Main circuits/overvoltage category6kV/III @ rated impulse withstand voltage (Uimp)
Auxiliary circuits/overvoltage category-inv6kV/III @ rated impulse withstand voltage (Uimp)
Width45 mm
Depth74.5 mm
Height90 mm
Contactor size (Type 2 coordination), min-inv100-C09 @ 600V
Frame sizeFrame size C, 32 A
Contactor size, min-inv100-K05: UL-508-Type F combination motor controller
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP2X
Weight317 lb
Mechanical life operations100000 /h
Breaking capacityStandard breaking capacity
Protection typeAdjustable thermal/fixed magnetic (13 x In)
Factory optionNo circuit-breaker auxiliary or trip contacts
Terminal typeScrew connection
Vibration resistanceOperation (60068-2-6): 5 G
Shock resistanceTransport (60068-2-27): 30 G, 11 ms, all axes
Ambient storage temperature-40 °C
Ambient operating temperature-25 °C
Ambient temperature compensation-20 °C
Site altitudeTo 2000 N.N.(m)
Moisture heat40 °C, relative humidity 93 %, 56 days (60068-2-3)-inv
Dry heat100 °C, relative humidity < 50 %, 7 days (60086-2-2)-inv
Dependence on temperatureNo current reduction @ 60 °C-inv
Moisture change climate23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv
Pollution degree3
Utilization categoryMotor starter: AC-3 (IEC60947-4-1)
Overload protection characteristicsIEC 60947-4-1 motor protection