Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

ROCKWELL AUTOMATION 140M-D8N-B25
ROCKWELL AUTOMATION 140M-D8N-B25
ROCKWELL AUTOMATION 140M-D8N-B25
ROCKWELL AUTOMATION 140M-D8N-B25
ROCKWELL AUTOMATIONAvailable

MCP, Standard Magnetic Trip (Fixed at 13 x le), 2.5 A, High Performance, Frame Size D

MCP, Standard Magnetic Trip (Fixed at 13 x le), 2.5 A, High Performance, Frame Size D
Product Code: 140M-D8N-B25
Partner cod.: 140M-D8N-B25
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Number of poles3
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100 kA
Complete device with protection unitYes
Rated permanent current Iu2.5 A
Rated voltage230 V
Type of control elementTurn button
Magnetic release current per IEC32 A
Rated operational current (Ie) per IEC2.5 A
Current range2.5 A
Rated supply current (Ie)1.6 A
Ultimate interrupting current for group motor installation65 kA @ 480V
Ultimate short circuit breaking capacity (Icu) per IEC100 kA @ 500V
Rated service short circuit breaking capacity (Ics) per IEC100 kA @ 500V
Magnetic trip current33 A
Hp rating, max2 Hp @ 575V, 3-phase
Rated insulation voltage (Ui)Rated 690V per IEC, SEV, VDE0660
KW rating, max1.8 kW @ 690V (AC-3), 3-phase
Switching of standard motors per IEC1.8 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IECNo back-up fuse required @ 500V
Short circuit current (Type 2 coordination), max65 kA @ 480V
Short circuit current for UL 508 Type E (Self-Protected) combination motor controller, max65 kA @ 480Y/277V with 100-C contactors
Total power loss (Pv) for circuit breaker6...11.6 W @ rated load operating temperature
Electrical life cycle100000 operations (Ie maximum)
Rated thermal current (Ith)1.6…32 A up to 60 °C ambient temperature
Fuse or circuit breaker per NEC, max450 A, UL 508—manual motor controller
Fuse or circuit breaker rating per NEC, max450 A, UL 508—manual motor controller with 100-C contactor
Rated impulse withstand voltage (Uimp)Main circuits (Uimp)/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max65 kA @ 480V, UL 508—manual motor controller with 100-C contactors
Short circuit current for motor disconnect, max65 kA @ 480V, UL 508—manual motor controller with 100-C contactors
Magnetic release current (±20 %)Fixed setting 13...14 x Ie maximum (Ie maximum = maximum values of setting ranges)
Protection typeFixed magnetic only (13 x In)
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Switching frequency, max25 ops/h
Rated frequency50/60 Hz
Phase loss protectionDifferential release
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Degree of protection (IP)IP2X
Weight365 lb
Mechanical life operations100000 /h
Breaking capacityHigh breaking capacity
VibrationOperation (60068-2-6): 5 G
ShockTransport (60068-2-27): 30 G, 11 ms, all axes
Factory optionNo circuit-breaker auxiliary or trip contacts
Ambient storage temperature-40 °C
Ambient operating temperature-25 °C
Ambient temperature compensation-20 °C
Site altitude2000 m (NN)
Dependence on temperatureNo reduction @ 60 °C (140 °F)
Pollution degree3
Moisture heat (60068-2-3)40 °C, relative humidity 93 %, 56 days
Dry heat (60086-2-2)100 °C, relative humidity < 50 %, 7 days
Moisture change climate (600068-2-30)23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles
Frame sizeFrame size D, 32 A
Contactor size (Type 2 coordination), min100-C30 @ 600V
Contactor size, min100-C23, UL-508—Type E (self-protected) combination motor controller with 100-C contactor
Device constructionBuilt-in device fixed built-in technique
Utilization categoryMotor starter: AC-3 (IEC60947-4-1)
Technical Specs
Specifications
Type:High Breaking Capacity
System Voltage Data
Supply Voltage:480V 60Hz
Circuit Breaker
Circuit Breaker Type:Motor Circuit Protector
Rated Operational Current (A):2.5A
Application:Standard Magnetic Trip (Fixed at 13 x le)
Frame Size:Frame Size D
Magnetic Trip Current (A):33A Fixed
Breaking Capacity:High Breaking Capacity
UL Listed Application Ratings:UL 508 - Manual Motor Controller
Short Circuit Coordination
Coordination Type:Type 1
Options
Side Mount Shunt Trip and Undervoltage Release:None
Front Mount Auxiliary and Trip Contacts:None
Side Mount Auxiliary and Trip Contacts (TESTDESC):None