Motor Circuit Protector Circuit-Breaker

MCP, Standard Magnetic Trip (Fixed at 13 x le), 25 A, High Performance, Frame Size D
Product Code: 140M-D8N-C25
Partner cod.: 140M-D8N-C25
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Tecnichal data
Number of poles3
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65 kA
Complete device with protection unitYes
Rated permanent current Iu25 A
Rated voltage230 V
Type of control elementTurn button
Magnetic release current per IEC325 A
Rated operational current (Ie) per IEC25 A
Current range25 A
Rated supply current (Ie)1.6 A
Ultimate interrupting current for group motor installation30 kA @ 480V
Ultimate short circuit breaking capacity (Icu) per IEC65 kA @ 400/415V
Rated service short circuit breaking capacity (Ics) per IEC4 kA @ 690V
Magnetic trip current325 A
Hp rating, max7.5 Hp @ 230V, 3-phase
Rated insulation voltage (Ui)Rated 690V per IEC, SEV, VDE0660
KW rating, max5.5 kW @ 230V (AC-3), 3-phase
Switching of standard motors per IEC5.5 kW @ 230/240V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IECNo back-up fuse required @ 230/240V
Short circuit current (Type 2 coordination), max65 kA @ 480V
Short circuit current for UL 508 Type E (Self-Protected) combination motor controller, max65 kA @ 480Y/277V with 100-C contactors
Total power loss (Pv) for circuit breaker6...11.6 W @ rated load operating temperature
Electrical life cycle100000 operations (Ie maximum)
Rated thermal current (Ith)1.6…32 A up to 60 °C ambient temperature
Fuse or circuit breaker per NEC, max450 A, UL 508—manual motor controller
Fuse or circuit breaker rating per NEC, max450 A, UL 508—manual motor controller with 100-C contactor
Rated impulse withstand voltage (Uimp)Main circuits (Uimp)/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max30 kA @ 600V, UL 508—manual motor controller with 100-C contactors
Short circuit current for motor disconnect, max30 kA @ 600V, UL 508—manual motor controller with 100-C contactors
Magnetic release current (±20 %)Fixed setting 13...14 x Ie maximum (Ie maximum = maximum values of setting ranges)
Protection typeFixed magnetic only (13 x In)
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Switching frequency, max25 ops/h
Rated frequency50/60 Hz
Phase loss protectionDifferential release
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Degree of protection (IP)IP2X
Weight365 lb
Mechanical life operations100000 /h
Breaking capacityHigh breaking capacity
VibrationOperation (60068-2-6): 5 G
ShockTransport (60068-2-27): 30 G, 11 ms, all axes
Factory optionNo circuit-breaker auxiliary or trip contacts
Ambient storage temperature-40 °C
Ambient operating temperature-25 °C
Ambient temperature compensation-20 °C
Site altitude2000 m (NN)
Dependence on temperatureNo reduction @ 60 °C (140 °F)
Pollution degree3
Moisture heat (60068-2-3)40 °C, relative humidity 93 %, 56 days
Dry heat (60086-2-2)100 °C, relative humidity < 50 %, 7 days
Moisture change climate (600068-2-30)23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles
Frame sizeFrame size D, 32 A
Contactor size (Type 2 coordination), min100-C30 @ 600V
Contactor size, min100-C30, UL 508—Type E self-protected combination motor controller with 100-C contactors
Device constructionBuilt-in device fixed built-in technique
Utilization categoryMotor starter: AC-3 (IEC60947-4-1)
Technical Specs
Specifications
Type:High Breaking Capacity
System Voltage Data
Supply Voltage:480V 60Hz
Circuit Breaker
Circuit Breaker Type:Motor Circuit Protector
Rated Operational Current (A):25A
Application:Standard Magnetic Trip (Fixed at 13 x le)
Frame Size:Frame Size D
Magnetic Trip Current (A):325A Fixed
Breaking Capacity:High Breaking Capacity
UL Listed Application Ratings:UL 508 - Manual Motor Controller
Short Circuit Coordination
Coordination Type:Type 1
Options
Side Mount Shunt Trip and Undervoltage Release:None
Front Mount Auxiliary and Trip Contacts:None
Side Mount Auxiliary and Trip Contacts (TESTDESC):None
Description
Circuit-Breaker, Motor Circuit Protector, TheMaxRtgForMPCBs=630.0A, 25A, Frame Size D, High Breaking Capacity, No Bus Bar Mount, 25 A, No Knob Adaptor Modification, for Thermal Overloads, None, None, None, Std Mgntc Tr (Fxd at 13 x le)., None, UL 508 - Manual Motor Cntrlr, None, Trigger Constraints, None, No Options Right