ROCKWELL AUTOMATIONNot available

Smart Motor Controller, 85 A 15-60 Hp at 460V AC, 600V AC 50/60 Hz Three-Phase, Open, 100...240V AC, Braking Control

SMC-Flex, Solid State Controller, Open, 85 A, 15...60Hp @ 460V AC, Input Volt.: 200...600V, Control Volt.: 100...240V AC, Braking Control Option
Product Code: 150-F85NCDD
Partner cod.: 150-F85NCDD
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Tecnichal data
With displayYes
Voltage type for actuatingAC
Rated operating voltage Ue200 V
Rated control supply voltage at AC 50 Hz100 V
Rated control supply voltage at AC 60 Hz100 V
Overload current for line connected devices17 A
Overload current for delta connected devices29.4 A
Controller typeSoft starter
Control optionsBrake control
Trip classes10, 15, 20 and 30
Trip current rating117% of motor FLC
Transformer control module75VA @ 100...240V AC (-15%, +10%)
Heatsink fan rating20VA @ 110/120V AC or 220/240V AC
DV/DT protectionRC snubber network for power circuit
Repetitive peak inverse voltage rating1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz for power circuit
Line connected motor power, max75 Hp @ 575V AC, 60 Hz, 3-phase
Delta connected motor power, max90 kW @ 500V AC, 50 Hz, 3-phase
Rated impulse voltage6000V per IEC for power circuit
Dielectric withstand2500V per IEC for power circuit
Line connected motor current17...85 A @ 500/575V AC, 3-phase
Delta connected motor current29.4...147 A @ 500/575V AC, 3-phase
Transient protectionMetal oxide varistors: 220 Joules (optional) for power circuit
Insulation voltageRated 500V per IEC for power circuit
Rated operational voltage200...600V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current<10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device listStandard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts1 for auxiliary contacts
High capacity available fault current, max70 kA @ 600V, maximum current 200 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentAC for auxiliary contacts
Conventional thermal current (Ith)AC/DC: 5 A for auxiliary contacts
Type of control circuitElectromagnetic relay for auxiliary contacts
Type of contactsProgrammable NO/NC for auxiliary contacts
Utilization categoryMG 1 per UL/CSA/NEMA for power circuit
Standard controller featureStatus indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max10 kA @ 200...600V, maximum standard fuse 400 A for delta device operational current rating
Optional controller featureSMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
Number of sensors, max6 for PTC input ratings
Inrush current control module5 A @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = open), max30V for PTC input ratings
Transient watts control module60 W @ 24V DC (-15%, +10%)
Steady state watts control module24 W @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = 4 kΩ), max<7.5 for PTC input ratings
Response time800 ms for PTC input ratings
Inrush time control module250 ms @ 24V DC (-15%, +10%)
Transient time control module500 ms @ 24V DC (-15%, +10%)
Cold resistance of PTC sensor chain, max1500 Ohm for PTC input ratings
Tachometer input0...5V DC, 4.5V DC = 100% Speed
Allen bradley power supply control module, min1606-XLP50E @ 24V DC (-15%, +10%)
Short circuit trip resistance25 Ohm ± 10 Ohm for PTC input ratings
Response resistance3400 Ohm ± 150 Ohm for PTC input ratings
Reset resistance1600 Ohm ± 100 Ohm for PTC input ratings
Input OFF-state voltage, max50V AC, 10V DC/12V AC for control circuit
Input ON-state voltage, min85V AC, 19.2V DC/20.4V AC for control circuit
Lower line side cable size0.8...2.5 mm2 (18...14 AWG) for power terminals
Lower load side cable size0.8...2.5 mm2 (18...14 AWG) for power terminals
Upper load side cable size2.5...50 mm2 (14...1 AWG) for load power terminals
Upper line side cable size2.5...95 mm2 (14...3/0 AWG) for line power terminals
Rated operational current3 A @ 120V AC, 1.5 A @ 240V AC for auxiliary contacts
Input ON-state current20 mA @ 120V AC/40mA @ 240V AC, 7.6 mA @ 24V AC/DC for control circuit
Contact typeauxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Steady state heat dissipation with control and fan power129 W
Storage and transportation temperature-20 °C
Humidity5...95% (noncondensing)
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
Protection against electrical shockIP20 per IEC for power circuit
EMC emission levelsRadiated emission: Class A
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2
Altitude2000 m
Pollution degree2
Weight5.7 kg
ShockOperational: 15 G
Width150 mm (5.90 inch)
Depth203 mm (8 inch)
Height321 mm (12.60 inch)
Power pole constructionHeatsink thyristor modular design
VibrationOperational: 1.0 G peak, 0.15 mm (0.006 inch) displacement
Make3600VA for auxiliary contacts
Break360VA for auxiliary contacts
Tightening torque14.7 Nm (130 lb.inch) for power terminals
Internal bypassYes
FunctionSingle direction
Power terminal markingsNEMA, CENELEC EN50 012
Control terminalsClamping yoke connection, M3 screw clamp
Wire strip length18...20 mm (0.22...0.34 inch) for power terminals
Number of poles3
EnclosureOpen type
Control modules constructionThermoset and thermoplastic moldings
Metal parts constructionPlated brass, copper or painted steel