ROCKWELL AUTOMATION 1783-BMS12T4E2CGNK
ROCKWELL AUTOMATION 1783-BMS12T4E2CGNK
ROCKWELL AUTOMATIONNot available

Stratix 5700, 12 copper 10/100 ports, 4 PoE ports, 2 combo(copper or SFP slot) 10/100/1000 ports, full FW, 1588 PTP, NAT.conformal coating

Stratix 5700 Switch, Managed, 12 Copper 10/100 Ports, 4 PoE Ports, 2 Combo(Copper or SFP Slot) 10/100/1000 Ports, Full FW, 1588 PTP, NAT, Conformal Coating, DLR
Product Code: 1783-BMS12T4E2CGNK
Partner cod.: 1783-BMS12T4E2CGNK
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Tecnichal data
Width12.7 cm
Height12.95 cm
Depth13.58 cm
Approximate weight1.11 kg
Screw torque, ground terminal, maximum0.96 Nm
Line voltage, nomYes
Screw torque, power and alarm terminals0.23 Nm
Number of ports 10/100 Mbps RJ4512
Number of combination-ports RJ45/Mini GBIC2
Layer 2No
Layer 3No
ManageableYes
Power over Ethernet802.3 af (PoE)
Number of ports PoE4
Max. PoE power30 W
Power consumption, maximum30 W
Power dissipation30 W
Firmware typeFull
Number of combination ports 10/100/1000 Mbps2
Power consumption at 24V DC, 40 ˚C15 W
Total number of ports18
Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire0.5 mm²
Wire size, DC power connection, solid or stranded copper wire rated at 75 °C or greater0.5 mm²
Wire size, ethernet connectionRJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Mounting methodDIN rail (top hat rail)
EthernetYes
Protection typeAlarm not rated
Alarm relay at 30V DC1 A
Alarm relay at 48V DC0.5 A
CIP sync (IEEE 1588)Yes
DLRYes
Ethernet data rate10/100 Mbps
Isolation voltage (continuous), basic insulation type, DC power ports to ground, and PoE power ports to ground60 V
Maximum insulation, DC power connection1.2 mm
NATYes
Power input at 12 - 48V DC, class 2/SELV0.5 A
Power over Ethernet input power, DC48 V
Wire size, ground connection, stranded copper wire, minimum4 mm²
Wire strip length, alarm connection6.3±0.5 mm
Wire strip length, DC power connection6.3±0.5 mm
Wiring category on console and alarm ports3
Wiring category on DC power ports2
Wiring category on Ethernet ports2
Housing base materialOpen-style
Nominal positionT4
Temperature, surrounding air, maximum60 °C
EFT/B immunity for IEC 61000-4-4 at 5 kHz on alarm ports±4 kV
EFT/B immunity for IEC 61000-4-4 at 5 kHz on Ethernet ports±4 kV
Emissions, CISPR11 (IEC 61000-6-4)Class A
ESD immunity, IEC 61000-4-2, air discharges8 kV
ESD immunity, IEC 61000-4-2, contact discharges6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 1000 - 2700 MHz1 Kg/Km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz10 Kg/Km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz10 Kg/Km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)50 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)30 g
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports±2 kV
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)-40 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)-40 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)-40 °C
Selectable start timesT4
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)10 V
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power ports±2.5 kV
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power ports±1 kV
EFT/B immunity for IEC 61000-4-4 at 5 kHz on DC power ports±4 kV
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz10 Kg/Km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports±2 kV
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports±1 kV
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)-40 °C
Vibration, IEC 60068-2-6 (test Fc, operating) at 10 - 500 Hz2 g
Technical Specs
Specifications
Sub Brand:Stratix 5700
Environmental Conditions:IP30
Port:18
ITConnectivity:Yes
Stratix Family Selection Assistance - Optional
Type:Managed Switch
# of Copper Ports Required:9 to 20
Do you need connectivity to an IT environment? (using Cisco technology and tools (CLI, CNA, CiscoWorks)):Yes
Do you need any of these network services?:At least one of the following: Aggregation (EtherChannel), Flexlinks, Access Control Lists (ACLs), 802.1x security, TACACS+ and Radius Authentication, IPV6 support.
Do you need routing capability..?:No
Do you Need PoE(Power Over Ethernet):Yes
Do you need integrated DLR?:Yes
Data
Stratix Ethernet Family:Stratix 5700
Environment:IP30
Ethernet Family:Stratix 5700 Switch, Managed, 12 Copper 10/100 Ports, 4 PoE Ports, 2 Combo(Copper or SFP Slot) 10/100/1000 Ports, Full FW, 1588 PTP, NAT, Conformal Coating, DLR
Accessories
Network Media:Male RJ45 to Male RJ45 Patchcord, Unshielded Twisted Pair, Teal TPE Cable, 1.9 m
Factory Talk Manager:FactoryTalk Network Manager License (download)
Additional Details
Mounting:Din Rail
Operating Temperature:-40..60 °C (-40...140 °F)
Ports per Module:18
Description
Stratix 5700, 12 copper 10/100 ports, 4 PoE 10/100 ports, 2 combo (copper of SFP slot) 10/100/1000 ports, Full FW, 1588 PTP, NAT, Conformalcoating