ROCKWELL AUTOMATION 1783-BMS4S2SGL
ROCKWELL AUTOMATION 1783-BMS4S2SGL
ROCKWELL AUTOMATION 1783-BMS4S2SGL
ROCKWELL AUTOMATION 1783-BMS4S2SGL
ROCKWELL AUTOMATIONAvailable

Stratix 5700, 4 SFP 10/100 slots, 2 SFP 10/100/1000 slots, lite FW

Stratix 5700 Switch, Managed,6 SFP slots(4 fast Ethernet ports;2 Gigabit ports) lite firmware
Product Code: 1783-BMS4S2SGL
Partner cod.: 1783-BMS4S2SGL
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Tecnichal data
Width8 cm
Height12.95 cm
Depth12.19 cm
Approximate weight1.22 kg
Screw torque, ground terminal, maximum0.4 Nm
Screw torque, power and alarm terminals0.23 Nm
Layer 2No
Layer 3No
ManageableYes
Power consumption, maximum14 W
Power dissipation14 W
Firmware typeLite
Isolation voltage (continuous), basic insulation type, DC power ports to ground, DC power ports to ethernet ports, and DC power ports to alarm ports60 V
Number of ports 10/100 Mbps SFP4
Number of ports 10/100/1000 Mbps SFP2
Power consumption at 24V DC, 40 ˚C12.5 W
Total number of ports6
Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire0.5 mm²
Wire size, DC power connection, solid or stranded copper wire rated at 75 °C or greater0.5 mm²
Mounting methodDIN rail (top hat rail)
EthernetYes
Protection typeAlarm not rated
Alarm relay at 30V DC1 A
Alarm relay at 48V DC0.5 A
Maximum insulation, DC power connection1.2 mm
Power input at 12 - 48V DC, class 2/SELV0.5 A
Wire size, ground connection, stranded copper wire, minimum4 mm²
Wire strip length, alarm connection6.3±0.5 mm
Wire strip length, DC power connection6.3±0.5 mm
Wiring category on console ports3
Wiring category on DC power and alarm ports2
Degree of protection (IP)IP30
Housing base materialOpen-style
Nominal positionT4
Temperature, surrounding air, maximum60 °C
Emissions, CISPR11 (IEC 61000-6-4)Class A
ESD immunity, IEC 61000-4-2, air discharges8 kV
ESD immunity, IEC 61000-4-2, contact discharges6 kV
Magnetic field immunity, IEC 61000-4-8, long duration at 50 ans 60 Hz (A/m)300
Magnetic field immunity, IEC 61000-4-8, short duration at 50 ans 60 Hz (A/m)1000
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz20 Kg/Km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz10 Kg/Km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)50 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)30 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)-40 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)-40 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)-40 °C
Selectable start timesT4
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)10 V
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on alarm ports at 1 MHz and 100 kHz±2.5 kV
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power ports at 1 MHz and 100 kHz±2.5 kV
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on alarm ports at 1 MHz and 100 kHz±1 kV
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power ports at 1 MHz and 100 kHz±1 kV
EFT/B immunity for IEC 61000-4-4 at 2.5, 5, and 100 kHz on alarm ports±4 kV
EFT/B immunity for IEC 61000-4-4 at 2.5, 5, and 100 kHz on DC power ports±4 kV
Magnetic pulse immunity, IEC 61000-4-9 (A/m)300
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 1000 MHz20 Kg/Km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz10 Kg/Km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on alarm ports±2 kV
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports±2 kV
Surge transient immunity, IEC 61000-4-5, line-line (DM) on alarm ports±1 kV
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports±1 kV
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)-40 °C
Vibration, IEC 60068-2-6 (test Fc, operating) at 10 - 500 Hz2 g
Voltage variation IEC 61000-4-29, interruption on DC power ports10 ms
Technical Specs
Specifications
Sub Brand:Stratix 5700
Environmental Conditions:IP30
Stratix Family Selection Assistance - Optional
Type:Managed Switch
# of Copper Ports Required:8 or less
# of Fiber Ports Required:5 or More
Do you need routing capability..?:No
Do you Need PoE(Power Over Ethernet):No
Do you need integrated DLR?:No
Data
Stratix Ethernet Family:Stratix 5700
Environment:IP30
Ethernet Family:Stratix 5700 Switch, Managed,6 SFP slots(4 fast Ethernet ports;2 Gigabit ports) lite firmware
Accessories
Network Media:Male RJ45 to Male RJ45 Patchcord, Unshielded Twisted Pair, Teal TPE Cable, 1.9 m
Factory Talk Manager:FactoryTalk Network Manager License (download)
Additional Details
Mounting:Din Rail
Operating Temperature:-40..60 °C (-40...140 °F)
Description
Stratix 5700, 4 SFP 10/100 slots, 2 SFP 10/100/1000 slots, lite FW