ROCKWELL AUTOMATION 2080-IF2
ROCKWELL AUTOMATION 2080-IF2
ROCKWELL AUTOMATION 2080-IF2
ROCKWELL AUTOMATION 2080-IF2
ROCKWELL AUTOMATIONAvailable

Micro800 2 Point Analog Input Plug-In

2080 Micro800 System, 2-ch V/I Analog Input Unipolar 0-10V/0-20mA (non-isolated)
Product Code: 2080-IF2
Partner cod.: 2080-IF2
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Tecnichal data
Number of analogue inputs2
Resolution of the analogue inputs12 Bit
Input, currentYes
Input, voltageYes
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Input signal, configurableNo
Output, currentNo
Output, voltageNo
Output signal configurableNo
Analogue inputs configurableYes
Analogue outputs configurableNo
Type of electric connectionScrew connection
Data range0 to 65535
Channel to channel isolationNon-isolation
Update time180 ms per enabled channel
Input group to bus isolationNo isolation
Module errorVoltage: ±1.5% @ over full temperature range, -20...65°C (-4...149°F), Current: ±2.0% @ over full temperature range, -20...65°C (-4...149°F)
Wire sizeSolid: 0.14 mm2 (26 AWG)...1.5 mm2 (16 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 (26 AWG)...1.0 mm2 (18 AWG) @ Rated @ 90 °C (194 °F) insulation maximum
Suitable for safety functionsNo
SIL according to IEC 61508None
Recommended maximum shielded cable length10 m
Voltage ranges0 V
Current range0 mA
Field input calibrationNot required
Overall accuracyVoltage terminal: ±1% full scale @ 25°C, Current terminal: ±1% full scale @ 25°C
Surrounding air temperature, max65 °C
North American temperature codeT4
Power consumption<60 mA @ 3.3V
EmissionsCISPR 11 (IEC 61000-6-4): Class A
ESD immunityIEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
EFT/B immunityIEC 61000-4-4: ±2 kV @ 5 kHz on shielded ports
Relative humidityIEC 60068-2-30 (Test Db, unpackaged damp heat), 5...95% noncondensing
Conducted RF immunityIEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunityIEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports
Operating temperature-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
Radiated RF immunityIEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
Operating altitude2000 m
Nonoperating temperature-40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
Non-linearity±0.1% @ in percent full scale
Repeatability±0.1%
VibrationIEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz
ShockIEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating
Mounting torque0.2 Nm
Terminal screw torque0.22...0.25 Nm (1.95...2.21 lb-in) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)
Input impedance>100 kΩ for voltage mode, 250 Ω for current mode
Explosion safety category for gasNone
Explosion safety category for dustNone
Technical Specs
Plug-In Modules
Plug-In Modules:2-ch V/I Analog Input Unipolar 0-10V/0-20mA (non-isolated)
Description
Analog Input, 2 Unipolar Non Isolated Points, Voltage/Current, 0-10V DC, 0-20 mA