Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

ROCKWELL AUTOMATION 20AC030A0AYNANC0
ROCKWELL AUTOMATIONAvailable

PowerFlex 70 AC Drive 30 A at 15 kW 20A

PowerFlex70 AC Drive, 400 VAC, 3 PH, 30 Amps, 15 kW Normal Duty, 11 kW Heavy Duty,Panel Mount - IP20 / NEMA Type 1, with conformal coating, No HIM (Blank Plate), Brake IGBT Installed, Without Drive Mounted Brake Resistor, Second Environment Filter per CE EMC directive (89/336/EEC), No Communication Module, Enhanced Control , No Feedback
Product Code: 20AC030A0AYNANC0
Partner cod.: 20AC030A0AYNANC0
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Tecnichal data
Degree of protection (IP)IP20
Shock15 G peak for 11 ms duration (±1.0 ms)
Vibration0.152 mm (0.006 inch) displacement, 1 G peak
Number of analogue outputs1
Mains voltage400 V
Integrated breaking resistanceNo
Internal dynamic brake resistors62 Ohm
Brake IGBTBrake IGBT installed
Bus undervoltage output shutoff305V DC @ 380/400V
Bus undervoltage fault level300V DC @ 380/400V
Internal communication moduleNo communication module
AC input undervoltage trip233V AC @ 380/400V
Bus voltage, nom540V DC @ 380/400V
Bus overvoltage trip810V DC @ 380/400V
Circuit breaker current rating, max120 A @ 400V AC, 3-phase
Motor circuit protector current rating, max50 A @ 400V AC, 3-phase
Output current rating, continuous30 A @ 400V AC, 3-phase
Output current rating, 1 min33 A @ 400V AC, 3-phase
Output current rating, 3 sec45 A @ 400V AC, 3-phase
Logic control ride-thru0.5 seconds minimum, 2 seconds typical
Brake resistorWithout drive mounted brake resistor
Input current rating30.3 A @ 400V AC, 3-phase
DocumentationManual
Carrier frequencyStandard control: 2, 3, 4, 5, 6, 7, 8, 9, and 10 kHz, vector control: 2, 4, 8, and 12 kHz, drive rating based on 4 kHz
Encoder quadrature90° ±27°
AC input overvoltage trip475V AC @ 380/400V
Input power rating21 kVA @ 400V AC, 3-phase
Dual element time delay fuse current rating40...60 A @ 400V AC, 3-phase
Non-time delay fuse current rating40...120 A @ 400V AC, 3-phase
Heat sink thermistorMonitored by microprocessor overtemp trip
Drive to motor power ratio, maxRecommended not greater than 2:1 ratio
Stop modesMultiple programmable stop modes including — Ramp, Coast, DC-brake, Fast brake, Ramp-to-hold and S-curve
Frequency accuracyDigital input: within ±0.01% of set output frequency
Acceleration/decelerationTwo independently programmable accel and decel times. Each time can be programmed from 0...3600 seconds in 0.1 second increments
Number of digital inputs6
Number of digital outputs2
Number of analogue inputs2
Internal watts loss42.9 W @ 400V, 15 Hp normal duty
Motor voltage, nom460V @ 380...480V drive rating, 480V nominal line voltage
Supporting protocol for DeviceNetYes
Human interface modelNo HIM-blank plate
Application in industrial area permittedYes
External watts loss432.9 W @ 400V, 15 Hp normal duty
Total watts loss475.8 W @ 400V, 15 Hp normal duty
Supporting protocol for EtherNet/IPYes
Line voltage, nom480V @ 380...480V drive rating, 460V nominal motor voltage
Mains frequency50 Hz
Output frequency rangeStandard control: 0...400 Hz, enhanced control: 0...500 Hz
Internal EMC filteringSecond environment filter per CE EMC directive (89/336/EEC)
Feedback optionNo feedback
Drive full power range460...528V @ 380...480V drive rating, 460V nominal motor voltage
Drive operating range342...528V @ 380...480V drive rating, 460V nominal motor voltage
Torque regulationWithout feedback +/-10%, with feedback +/-5%
Enclosure typePanel mount-IP20/NEMA Type 1
Output current rating30 amps, 15 kW normal duty, 11 kW heavy duty, frame D
Cooling fan operationFrames B, D, and E: fan operates when power is applied and in run condition
Control optionsEnhanced control with 24V I/O
Drive overcurrent tripSoftware current limit: 20...160% of rated current
Efficiency97.5% at rated amps, nominal line volts
Encoder supply5V/12V configurable ±5%
Speed control-speed regulationWithout feedback (Vector Control mode): 0.1% of base speed across 120:1 speed range, 120:1 operating range, 30 rad/sec bandwidth
Current limit capabilityProactive current limit programmable from 20...160% of rated output current, Independently programmable proportional and integral gain
Selectable motor controlSensorless vector with full tuning. Standards V/Hz with full custom capability and vector control
Frequency control-speed regulationWith slip compensation (Volts per Hertz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth
Input phasesThree-phase input provides full rating for all drives. single-phase operation provides 50% of rated current
Control methodSine coded PWM with programmable carrier frequency. Ratings apply to all drives
Number of HW-interfaces RS-2322
Number of HW-interfaces RS-4852
Number of HW-interfaces USB2
Number of phases output3
Number of phases input3
Relative symmetric net voltage tolerance10 %
With control elementYes
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Application in domestic- and commercial area permittedYes
Motor overload protectionClass 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Input frequency tolerance47 Hz
Encoder duty cycle50% ±10%
Voltage tolerance-10 %
Displacement power factor (all drives)0.98 across speed range
Short circuit rating, max200000 amps symmetrical
Output voltage range0 to rated motor voltage
Encoder typeIncremental, dual channel
Power ride-thru15 milliseconds at full load
Short circuit tripPhase-to-phase on drive output
Ground fault tripPhase-to-ground on drive output
Drive to motor power ratio, minRecommended not less than 1:2 ratio
Control logic noise immunityShowering arc transients upto 1500V peak
Line transientsUp to 6000 volts peak per IEEE C62.41-1991
Short circuit current rating, maxMaximum short circuit current rating to match specified fuse/circuit breaker capability
Intermittent overload110% overload capability for up to 1 minute, 150% overload capability for up to 3 seconds
Height, approxIP66, NEMA/UL Type 4X/12 for indoor use: 350 mm
Depth, approxIP66, NEMA/UL Type 4X/12 for indoor use: 210.7 mm
Width, approxIP66, NEMA/UL Type 4X/12 for indoor use: 219.9 mm
Weight, approxIP66, NEMA/UL Type 4X/12 for indoor use: 9.13 kg
Altitude1000 m (3300 ft.) maximum without derating
Degree of protection (NEMA)1
Surrounding air temperature, maxIP20, NEMA/UL Type 1: 0...50 °C (32...122 °F) without derating
AtmosphereDrive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere
Storage temperature-40 °C
Relative humidity5...95% noncondensing
Pollution degree 1 according to EN 61800-5-1No pollution occurs, only dry non-conductive pollution occurs, and has no influence
Pollution degree 4 according to EN 61800-5-1The pollution generates persistent conductivity caused, for example, by conductive dust, rain or snow
Pollution degree 3 according to EN 61800-5-1Conductive pollution occurs, dry non-conductive pollution occurs and becomes conductive due to condensation
Pollution degree 2 according to EN 61800-5-1Normally only non-conductive pollution occurs, Occasionally a temporary conductivity, caused by condensation is expected when the drive is out of operation
Surrounding environment pollution degreeAll enclosures are acceptable for pollution degree 1 and 2, an enclosure that meets or exceeds IP54, NEMA/UL type 12, is required for pollution degree 3 and 4
Technical Specs
Specifications
Voltage Rating:400 VAC, 3 PH
Base Drive Information
Input Voltage:400 VAC, 3 PH
Output Current:30 Amps
Enclosure:Panel Mount - IP20 / NEMA Type 1, with conformal coating
Frame Size:Frame Size D
Brake IGBT:Brake IGBT
EMC Filtering Options:Second Environment Filter per CE EMC directive (89/336/EEC)
Options Information
Base Plus Options:Base Plus Options Method
Human Interface Module:No HIM (Blank)
Internal Communication Module:No Communication Module
Description
20A, 30 A at 15 kW, 400V AC Three-Phase, IP20/NEMA/UL 1, No Feedback, No HIM - Blank Plate, No Communication Module, W/ EMC Filt & ComModeChoke, Brake IGBT Installed, No Internal Brake Resistor, D Frame, Enhanced Control with 24V I/O, Documentation