PowerFlex 700 AC Drive 14 A at 10 Hp 20B

PowerFlex700 AC Drive, 480 VAC, 3 PH, 14 Amps, 10 HP Normal Duty, 7.5 HP Heavy Duty, IP20 / Type 1, with conformal coating, No HIM (Blank Plate), Brake IGBT Installed, Drive Mounted Brake Resistor Installed, Second Environment Filter per CE EMC directive (89/336/EEC), No Communication Module, Vector Control with 24V I/O, Standard Encoder
Product Code: 20BD014A0AYYANC1
Partner cod.: 20BD014A0AYYANC1
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Tecnichal data
Degree of protection (IP)IP20
Shock15 G peak for 11 ms duration (±1.0 ms)
PWM frequency4 kHz @ 650V DC
Vibration0.152 mm (0.006 inch) displacement, 1 G peak
Number of analogue outputs2
Mains voltage480 V
Integrated breaking resistanceYes
Brake IGBTBrake IGBT installed
Internal communication moduleNo communication module
Fuse current rating30 A @ 650V DC
Input voltage rating480V AC, 3-phase, 60 Hz
AC input undervoltage trip280V AC @ 480V
Bus voltage, nom648V DC @ 480V
Bus undervoltage shutoff/fault305V DC @ 480V
Bus overvoltage trip810V DC @ 480V
Output voltage rating0...460V AC @ 480V AC, 1-phase
Circuit breaker current rating, max50 A @ 480V AC, 3-phase
Motor circuit protector current rating, max20 A @ 480V AC, 3-phase
Output current rating, continuous14 A @ 650V DC
Output current rating, 1 min16.5 A @ 650V DC
Output current rating, 3 sec22 A @ 650V DC
Logic control ride-thru0.5 seconds minimum, 2 seconds typical
Brake resistorWith internal brake resistor
Input current rating14.7 A @ 650V DC
DocumentationManual
Carrier frequency2, 4, 8, and 10 kHz. Drive rating based on 4 kHz
Encoder quadrature90 degrees, ±27 degrees at 25 °C (77 °F)
AC input overvoltage trip570V AC @ 480V
Input power rating10.4 kVA @ 480V AC, 3-phase
Dual element time delay fuse current rating17.5...30 A @ 480V AC, 3-phase
Non-time delay fuse current rating17.5...50 A @ 480V AC, 3-phase
Digital input latency, typical9.2 ms @ stop signal for SVC motor control
Heat sink thermistorMonitored by microprocessor overtemp trip
Digital input latency9.2...16.0 ms @ start signal for SVC motor control
Drive to motor power ratio, maxRecommended not greater than 2:1 ratio
Stop modesMultiple programmable stop modes including — Ramp, Coast, DC-brake, Fast brake, Ramp-to-hold and S-curve
Frequency accuracyDigital input: within ±0.01% of set output frequency
Acceleration/decelerationTwo independently programmable accel and decel times. Each time can be programmed from 0...3600 seconds in 0.1 second increments
Analog input latency, typical6.4 ms @ speed signal for SVC motor control
Number of digital inputs6
Number of digital outputs3
Number of analogue inputs2
Internal watts loss84 W @ 480V, 10 Hp normal duty (IP20, NEMA/UL Type 1)
Motor voltage, nom460V @ 380...480V drive rating, 480V nominal line voltage
Supporting protocol for DeviceNetYes
Human interface modelNo HIM (blank plate inserted)
Max. output frequency420 Hz
External watts loss134 W @ 480V, 10 Hp normal duty (IP20, NEMA/UL Type 1)
Total watts loss218 W @ 480V, 10 Hp normal duty (IP20, NEMA/UL Type 1)
Supporting protocol for EtherNet/IPYes
Line voltage, nom480V @ 380...480V drive rating, 460V nominal motor voltage
Mains frequency60 Hz
Actual short circuit ratingDetermined by AIC rating of installed fuse/circuit breaker
Internal EMC filteringWith EMC filter with common mode choke
Custom drive/firmwareNo custom firmware
Feedback optionStandard encoder
Analog input latency4.8...12.4 ms @ speed signal for SVC motor control
Drive full power range460...528V @ 380...480V drive rating
Drive operating range342...528V @ 380...480V drive rating
Torque regulationWith feedback: ±2 %, 2500 rad/sec bandwidth
Enclosure typeIP20/NEMA/UL Type 1
Output current rating7 A @ 480V AC, 1-phase
Control optionsVector control with 24V DC I/O
Drive overcurrent tripInstantaneous current limit: 220...300% of rated current (dependent on drive rating)
Efficiency97.5% at rated amps, nominal line volts
Encoder supply12V, 250 mA. 12V, 10 mA minimum inputs isolated with differential transmitter, 250 kHz maximum
Speed control-speed regulationWithout feedback (Vector Control Mode): 0.1 % of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
Current limit capabilityProactive current limit programmable from 20...160% of rated output current, Independently programmable proportional and integral gain
Selectable motor controlSensorless vector with full tuning. Standards V/Hz with full custom capability and vector control
Frequency control-speed regulationWith slip compensation (Volts per Hertz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth
Input phases3-phase input provides full rating for all drives. 1-phase operation possible on certain drives and provides 50 % of rated current. Frames 0...6: drive can be supplied as 6 pulse or 18 pulse in an engineered package.
Control methodSine coded PWM with programmable carrier frequency, ratings apply to all drives, the drive can be supplied as 6 pulse or 18 pulse in an engineered solution
Encoder requirementsEncoders must be line driver type, quadrature (dual channel) or pulse (single channel), 8...15V DC output (4...6V DC when jumpers are in 5V position), single-ended or differential and capable of supplying a min. of 10 mA per channel, maximum input frequen
Number of phases output3
Number of phases input3
Relative symmetric net voltage tolerance10 %
With control elementYes
Supporting protocol for LONYes
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Motor overload protectionFrames 0...6 vector control: powerflex 700 drives with vector control, which is identified by a C or D in position 15 of the catalog number, provide class 10 motor overload protection according to NEC article 430 and motor overtemperature protection acco
Input frequency tolerance47 Hz
Encoder duty cycle50% ±10%
Displacement power factor (all drives)0.98 across speed range
Short circuit rating, max200000 amps symmetrical
Output voltage range0 to rated motor voltage
Encoder typeIncremental, dual channel
Power ride-thru15 milliseconds at full load
Short circuit tripPhase-to-phase on drive output
Ground fault tripPhase-to-ground on drive output
Drive to motor power ratio, minRecommended not less than 1:2 ratio
Control logic noise immunityShowering arc transients upto 1500V peak
Line transientsUp to 6000 volts peak per IEEE C62.41-1991
Intermittent overload110% overload capability for up to 1 minute, 150% overload capability for up to 3 seconds
Height, approxIP20, NEMA/UL type 1: 336 mm
Depth, approxIP20, NEMA/UL type 1: 200 mm
Width, approxIP20, NEMA/UL type 1: 135 mm
Weight, approxIP20, NEMA/UL type 1: 9.98 kg (drive and packaging weight)
Sound levelFrame 1: 59 dB @ 30 CFM fan velocity
Altitude1000 m (3300 ft.) maximum without derating
Degree of protection (NEMA)1
Surrounding air temperatureIP20, NEMA/UL type 1 (with top label): 0...50 °C (0...122 °F) @ frames 5…6, most ratings
AtmosphereDrive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere
Operating temperature50 °C @ 650V DC
Storage temperature-40 °C
Relative humidity5...95% noncondensing
Pollution degree 1 according to EN 61800-5-1No pollution occurs, only dry non-conductive pollution occurs, and has no influence
Pollution degree 4 according to EN 61800-5-1The pollution generates persistent conductivity caused, for example, by conductive dust, rain or snow
Pollution degree 3 according to EN 61800-5-1Conductive pollution occurs, dry non-conductive pollution occurs and becomes conductive due to condensation
Pollution degree 2 according to EN 61800-5-1Normally only non-conductive pollution occurs, Occasionally a temporary conductivity, caused by condensation is expected when the drive is out of operation
Surrounding environment pollution degreeAll enclosures are acceptable for pollution degree 1 and 2, an enclosure that meets or exceeds IP54, NEMA/UL Type 12, is required for pollution degree 3 and 4