Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

ROCKWELL AUTOMATION 20DE041A0EYNANANK
ROCKWELL AUTOMATION 20DE041A0EYNANANK
ROCKWELL AUTOMATIONNot available

PowerFlex 700S AC Drive 20D

PowerFlex700S AC Drive, 600 VAC, 3 PH, 41 Amps, 40HP Normal Duty, 30HP Heavy Duty, IP20 / Type 1, with conformal coating, No HIM (Blank Plate), Brake IGBT Installed, Without Drive Mounted Brake Resistor, Second Environment Filter per CE EMC directive (89/336/EEC), No Communication Module, Phase II control, Expanded cassette, Standard (Incremental Encoder), Phase II, 5730 DriveLogix, no embedded comm
Product Code: 20DE041A0EYNANANK
Partner cod.: 20DE041A0EYNANANK
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Degree of protection (IP)IP20
Shock10 G peak for 11 ms duration (±1.0 ms)
PWM frequency4 kHz @ 810V DC
Vibration0.152 mm (0.006 in.) displacement, 1 G peak, 5.5 Hz
Number of analogue outputs2
Mains voltage600 V
Integrated breaking resistanceNo
Max. output voltage932 V
DC bus overvoltage trip1164V DC @ 600V
DC nominal bus voltage931V DC @ 600/690V
Brake IGBTBrake IGBT installed
Internal communication moduleNo communication module
Fuse current rating70 A @ 810V DC
Input voltage rating600V AC, 3-phase, 60 Hz
Displacement power factor0.98 across speed range
Output current, continuous41 A @ 810V DC
Output current, 1 min48 A @ 810V DC
Output current, 3 sec64 A @ 810V DC
Circuit breaker current rating, max150 A @ 600V AC, 3-phase
Motor circuit protector current rating, max100 A @ 600V AC, 3-phase
Logic control ride-thru0.25 seconds, drive not running
Brake resistorNo internal brake resistor
Cable20D-DL2-CL3, 20D-DL2-CR3
Input current rating43.9 A @ 810V DC
Rated power rating40 Hp @ 810V DC, normal duty
DocumentationEnglish documentation
Carrier frequencyDrive rating: 4 kHz, settings: 2, 4, 6, 8, 10 kHz (6 kHz is for V/Hz operation only)
AC input overvoltage trip863V AC @ 600V (six pulse, 3-phase)
Input power rating39.1 kVA @ 600V AC, 3-phase
Electronic motor overload protectionClass 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Dual element time delay fuse current rating50...90 A @ 600V AC, 3-phase
Non-time delay fuse current rating50...150 A @ 600V AC, 3-phase
Heat sink thermistorMonitored by microprocessor overtemperature trip
Drive to motor power ratio, maxThe drive to motor rating cannot exceed a 2:1 ratio
Stop modesMultiple programmable stop modes including – Ramp, Coast, and Current Limit
Acceleration/decelerationIndependently programmable accel and decel times adjustable from 0 to 6553.5 in 0.1 second increments
Number of digital inputs6
Number of digital outputs2
Number of analogue inputs3
Motor voltage, nom575V @ 500...690V drive rating
Human interface modelNo HIM (no blank plastic inserted)
Additional configurationPhase II DriveLogix 5730
Max. output frequency400 Hz
Line voltage, nom600V @ 500...690V drive rating
Mains frequency60 Hz
Internal EMC filteringWith EMC filter & common mode choke
User available memory base1.5 MB (compactflash for non-volatile storage also available)
Watt loss667 W @ 600V AC, 40 Hp normal duty, 30 Hp heavy duty
Feedback optionFuture use
Drive full power range575...660V @ 500...690V drive rating
Drive operating range475...759V @ 500...690V drive rating
Torque regulationTorque regulation - without feedback: ±5%, 600 rad/sec bandwidth
Battery1769-BA 0.59 g lithium
Enclosure typeIP20/NEMA/UL Type 1
Output current rating41 amps, 40 Hp normal duty, 30 Hp heavy duty, frame 3
Control optionsPhase II control, expanded cassette
Drive overcurrent tripSoftware current limit: 105% of motor rated to 200% of drive rated current
Efficiency97.5% at rated amps, nominal line volts
Speed controlSpeed regulation - without feedback: 0.1% of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
Current limit capabilityIndependent motoring and regenerative power limits programmable to 800% of rated output current
Selectable motor controlField oriented control with and without a feedback device and permanent magnet motor control
Serial cable1761-CBLPM02 to 1761-NET-AIC, 1761-CBLPA00 to 1761-NET-AIC, 1756-CP3 directly to controller,1747-CP3 directly to controller, category 3(2)
Input phasesSix-pulse, 3-phase input provides full rating for all drives, single-phase operation provides 50% of rated current
Control methodInduction motor and brushless motor: sine coded PWM with programmable carrier frequency, indirect self organized, field-oriented control, current-regulated, ratings apply to all drives, refer to the PowerFlex 700S Phase ll control reference manual, public
Number of phases output3
Number of phases input3
Relative symmetric net voltage tolerance10 %
Input frequency, max400 Hz
Output frequency range0 Hz
DC bus undervoltage tripAdjustable
Output voltage range0 to rated motor voltage
Power ride-thru15 milliseconds at full load
S-curve timeAdjustable 0.5...4.0 seconds
Short circuit tripPhase-to-phase on drive output
Ground fault tripPhase-to-ground on drive output
Control logic noise immunityShowering arc transients upto 1500V peak
Line transientsUp to 6000 volts peak per IEEE C62.41-1991
Compact I/O configurationUp to (16) modules (8 modules per bank or 4 max on either side of the power supply)
Intermittent overload110% overload capability for up to 1 minute, 150% overload capability for up to 3 seconds
Short circuit current, maxUsing recommended fuse or circuit breaker type: maximum short circuit current rating to match specified fuse/circuit breaker capability ≤200000 Amps
Encoder voltage supply5V DC or 12V DC 320 mA/channel, 5V DC minimum high state voltage state of 0.4V DC, 12V DC minimum high state voltage of 7.0V DC, maximum low state voltage of 0.4V DC
Height, approx517.5 mm
Depth, approx200 mm
Width, approx253.9 mm
Weight, approxDrive: 18.55 kg
Sound levelFrame 3: 61 dB @ 120 CFM fan speed
Altitude1000 m (3300 ft.) maximum without derating
Degree of protection (NEMA)1
AtmosphereDrive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors, or dust, If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosi
Operating temperature50 °C @ 810V DC
Storage temperature-40 °C
Relative humidity5...95% noncondensing
Surrounding air temperature without deratingNEMA/UL Type 1: 0° to 40° C (32° to 104° F)
Technical Specs
Base Drive Information
Input Voltage:600 VAC, 3 PH
Output Current:41 Amps
Enclosure:IP20 / Type 1, with conformal coating
Frame Size:Frame Size 3
Brake IGBT:Brake IGBT Installed
Brake Resistor:Without Drive Mounted Brake Resistor
EMC Filtering Options:Second Environment Filter per CE EMC directive (89/336/EEC)
Phase II, Control Options:Phase II control, Expanded cassette
Feedback Option:Standard (Incremental Encoder)
Additional Configurations:Phase II, 5730 DriveLogix, no embedded comm
Firmware:Standard
Options
Base Plus Options:Base Plus Options Method
Internal Communication Module:No Communication Module

Other products