Industrial Automation
Degree of protection (IP) | IP67 |
Length amplifier | 40 mm |
Width amplifier | 41.91 mm |
Height amplifier | 74.93 mm |
Wave length | 880 nm |
Sensing mode type | Fiber optic large aperture |
Sensing distance | Depends on fiber optic cable |
List of degrees of protection (IP) | IP69K, IP67 |
Operating environment | IP69K, IP67 with 1200 psi, NEMA 3, 4X, 6P, 12, 13, ECOLAB rated |
Setting procedure | Manual adjustment |
Vibration | 10...55 Hz, 1 mm amplitude, meets or exceeds IEC 60947-5-2 |
Shock | 30 G with 1 ms pulse duration, meets or exceeds IEC 60947-5-2 |
Voltage type | AC/DC |
Material housing | Plastic |
Rated control supply voltage at DC | 70 V |
Type of switching output | Other |
Type of light | Infrared light |
Type of electric connection | Cable |
Current consumption, max | 30 mA |
Operating voltage | 70...264V @ AC |
Load current | 300 mA @ 264V AC |
Connection type | 2 m, 300V cable |
Operating voltage/mode | AC/DC - MOSFET |
Protection type | Short circuit, reverse polarity, false pulse, overload |
LED status | Yellow ON: power is on |
Sensor types | Standard ON/OFF |
Output function | Selectable light or dark operate |
Housing material | Valox® |
With time function | No |
Construction type housing | Special construction |
Lens material | Acrylic |
Operating temperature | -34 °C |
Relative humidity | 5 % |
Ambient light immunity | Incandescent light 5000 lux |
Field of view | Depends on fiber optic cable |