Industrial Automation
Monitoring Safety Relay, Guardmaster, Guardlocking, Proximity Inputs Safety Relay (GLP), 1 Dual Channel Input, 2 PNP Proxes, 1 N.C. Solid State Auxiliary Output


SIL according to IEC 61508 | 2 |
Safety integrity level claim limit | 2 |
Hardware fault tolerance | 1 |
Safe failure fraction | 98.95 % |
PFH | 7.19E-9 |
PFD | 4.13E-09 |
Mode of operation | High demand mode |
With approval according to UL | Yes |
With approval for TUV | Yes |
Performance level according to EN ISO 13849-1 | Level d |
Mission time | 20 Year |
Hours of operation | 24 h |
MTTFd | 378 |
Days of operation | 365 Days |
DC avg. (EN ISO 13849-1) | 97.66 % |
Category | Up to 3 |
Performance level | Up to d |
T cycle | 8/28.8 (h/s) |
Rated operating frequency | 4 kHz |
Evaluation inputs | One- and two-channel |
Type of electric connection | Screw connection |
Power consumption | 2 W |
Rated control supply voltage Us at DC | 24 V |
Wire size | 0.2...2.5 mmò (24...14 AWG) |
Number of outputs, safety related, undelayed, with contact | 0 |
Number of outputs, safety related, delayed, with contact | 0 |
Number of outputs, signalling function, undelayed, with contact | 0 |
Number of outputs, signalling function, delayed, with contact | 0 |
Number of outputs, signalling function, undelayed, semiconductors | 1 |
Number of outputs, signalling function, delayed, semiconductors | 0 |
Voltage type for actuating | DC |
Suitable for safety functions | Yes |
With detachable clamps | Yes |
With feedback circuit | Yes |
Surge auxillary output current duration, max | 5 ms |
Surge safety output current duration, max | 5 ms |
Continuous auxiliary output current | 50 mA |
Surge auxiliary output current | 700 mA |
Aggregate current of outputs per module, max | 1.8 A |
Continuous safety output current, max | 0.5 A |
Surge safety output current, max | 1.5 A |
Number of outputs, safety related, undelayed, semiconductor | 2/4 |
Number of outputs, safety related, delayed, semiconductor | 0/2 |
Other output | SWS output |
Operating voltage range | 20.4 V |
Configurable logic | Logic setting 1 - cat 1 stop, logic IN off, Logic setting 2 - cat 1 stop with logic IN, Logic setting 3 - safe limited slow speed, logic IN off, Logic setting 4 - safe limited slow speed with logic IN, Logic setting 5...8 - guard locking with delayed unlo |
Operating temperature | -5 ðC |
Enclosure protection | IP40 (NEMA 1) |
Relative humidity | 90% |
Height | 119.4 mm |
Width | 22.5 mm |
Depth | 113.6 mm |
Vibration | 10...55 Hz, 0.35 mm |
Shock | Shock proof, operating: 10 G, 16 ms |
Function rotational speed monitoring | Yes |
Function standstill monitoring | Yes |
Description other products