Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

ROCKWELL AUTOMATION 440R-N23114
ROCKWELL AUTOMATION 440R-N23114
ROCKWELL AUTOMATIONAvailable

Safety Relay, MSR126.1T, 24V AC/DC, Automatic/Manual, Fixed, 22.5MM Housing Width, Infinite, One 2 N.C. Input, One LC Input, 2 Safety Output, CAT 4 Rated

440R Single Function Safety Relays, Dual Channel N/A,2 N.O., , 24V DC , Fixed,Automatic/Manual Reset
Product Code: 440R-N23114
Partner cod.: 440R-N23114
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Tecnichal data
Number of outputs, safety related, undelayed, with contact2
Number of outputs, safety related, delayed, with contact0
Number of outputs, signalling function, undelayed, with contact0
Number of outputs, safety related, undelayed, semiconductors0
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
With start inputYes
With muting functionNo
Voltage type for actuatingAC/DC
Rated control supply voltage at DC24 V
ModelBasic device
Type of electric connectionScrew connection
Evaluation inputsOne- and two-channel
Power consumption4 W
Terminal typeFixed
Fuses outputExternal: 6 A slow blow or 10 A quick blow
Rated thermal current (Ith)Non switching: 6 A maximum in one current path
Continuous safety output currentUL: B300, 5 A @ 250V AC, 24V AC, 6 A @ 24V DC, AC-15: 6 A @ 250V AC, DC-13: 3 A @ 24V DC
Wire size0.2 to 2.5 mm²
Electrical life cycle100000 (220V AC / 4 A / 880VA cosφ = 0.35), 500000 (220V AC / 1.7 A / 375VA cosφ = 0.6), 1000000 (30V DC / 2 A / 60 W), 2000000 (10V DC / 0.01 A / 0.1 W)
Number of outputs, signalling function, delayed, with contact0
With feedback circuitYes
Suitable for monitoring of magnetic switchesYes
Suitable for monitoring of proximity switchesYes
Suitable for monitoring of emergency-stop circuitsYes
Suitable for monitoring of optoelectronic protection equipmentYes
Suitable for monitoring of position switchesYes
Suitable for monitoring of tactile sensorsYes
Suitable for monitoring of valvesYes
Immediate safe dry No output2
Impulse withstand voltage2500 V
Switching current, min10 mA @ 10V
Output utilization per IEC 60947-4-1, resistiveDC-1: 6 A @ 24V DC
Utilization categoryUL: B300, 5 A/250V AC, 24V AC, 6 A/24V DC
Operating voltage range24V AC/DC, 0.85 to 1.1 x rated voltage 50 60 Hz
Output utilization per IEC 60947-5-1, inductiveP300, DC-13: 3 A @ 24V DC, 6 A @ 24V DC @ 6 ops/min
SIL according to IEC 615083
With approval according to ULYes
Stop category according to IEC 602040
Performance level according to EN ISO 13849-1Level e
Type of safety according to IEC 61496-14
With approval for TUVYes
With detachable clampsNo
Rated control supply voltage at AC 50 Hz24 V
Rated control supply voltage at AC 60 Hz24 V
Terminal protectionIP20
Weight160 g
Vibration10...55 Hz, 0.35 mm
Shock10 G, 16 ms, 100 shocks
Rail mounting possibleYes
Enclosure protectionIP40 (NEMA 1)
MTTFd375 year
DC avg99 %
T cycle8/28800 (h/s)
Category according EN ISO 13849-14
Mission time20 year
Hours of operation24 h
Days of operation365 Days
Operating temperature-5 °C
Relative humidityOperating: 90%
Pollution degree2
PFHd2.03e-09
Height75 mm
Width22.5 mm
Depth110 mm
Mounting35 mm DIN rail in enclosure to a min of IP54
ResetManual monitored or automatic/manual