Industrial Automation
Number of analogue inputs | 4 |
Input, current | Yes |
Input, voltage | Yes |
Input, resistor | Yes |
Input, resistance thermometer | Yes |
Input, thermocouple | Yes |
Output, current | No |
Output, voltage | No |
Analogue inputs configurable | Yes |
Analogue outputs configurable | No |
Type of electric connection | Screw-/spring clamp connection |
Local CJC sensor accuracy | ñ0.3 ðC |
Input range, current | 0...20 mA, 4....20 mA |
Remote CJC sensor accuracy | Based on specified thermistor: ñ0.3 ðC |
RTD excitation current | 600 üA, 3 wire mode, 100 üA, 2 wire mode |
Module keying | Electronic keying via programming software |
Scan time | Per channel: 625 üs, Per group: 2.5 ms |
Step response time to 63% of value | 7.5 ms (Notch filter 10 kHz) |
Module conversion method | Sigma-Delta, One 24-bit multiplexed ADC |
RTB torque | 5069-RTB18-SCREW, 5069-RTB14CJC-SCREW: 0.4 Nm (3.5 lbin) |
Overvoltage protection, max | Voltage, current, RTD, and thermocouple/mV modes: ñ30V DC |
Common mode voltage | ñ10V (Current mode and 3-wire RTD mode), ñ2V (Voltage mode) |
Data format | IEEE 32-bit floating point |
Wire category | 2 - shielded input ports, 2 - power ports, 1 wire per terminal for each signal port |
Power dissipation, max | Voltage mode: 1.8 W, Current mode: 2.1 W, RTD mode: 2.1 W, Thermocouple / millivolt mode: 1.8 W |
Indicators | 1 green/red module status indicator, 4 yellow/red I/O status indicators, 2 yellow/red CJC status indicators |
Thermal dissipation, max | Voltage mode: 6.1 BTU/hr, Current mode: 7.2 BTU/hr, RTD mode: 7.2 BTU/hr, Thermocouple/millivolt: 6.1 BTU/hr |
Accuracy drift with temperature | Voltage: 0.200% full scale, Current: 0.300% full scale, RTD: 0.200% full scale, Thermocouple/millivolt: 0.200% full scale |
Input Total Unadjusted Error (TUE) | Voltage: 0.300% full Scale, Current: 0.400% full Scale, RTD: 0.300% full Scale, Thermocouple/millivolt: 0.300% full Scale |
Inputs | 4 differential |
Wire size | 5069-RTB18-SPRING and 5069-RTB14CJCSPRING connections: 0.5...1.5 mmò (22...16 AWG) solid or stranded shielded copper wire rated at 105 ðC (221 ðF), or greater, 2.9 mm (0.11 in.), max diameter including insulation, single wire connection only, 5069-RTB18-S |
Calibrated accuracy | Voltage: 0.100% full scale @ 25 ðC Current: 0.100% full scale @ 25 ðC RTD: 0.100% full scale @ 25 ðC Thermocouple/millivolt: 0.100% full scale @ 25 ðC |
Suitable for safety functions | No |
Notch filter frequency at RPI of 2.5 ms, min | 10 kHz |
Input anti-aliasing filter cutoff frequency, typical | 500 Hz |
Onboard data alarming | Yes |
Scaling to engineering units | Yes |
Real-time channel sampling | Yes |
Thermocouple linearization | ITS-90 |
Input range, thermocouple / millivolt | ñ100 mV |
Common mode noise rejection ratio | 130 dB @ 50/60 Hz |
Overcurrent protection, max | Current mode: ñ30 mA |
Input range, voltage | ñ10V, 0...10V, 0...5V |
Notch filter at minimum RPI | 62.5 kHz (0.2 ms, 1 channel enabled) |
Input type, thermocouple | B, C, D, E, J, K, L (TXK/XK), N, R, S, T |
Normal mode noise rejection ratio | 65 dB @ 50/60 Hz, notch filter dependent |
Input digital filter | First order lag, 0 msâ⬦32,767 ms (32.767 s) |
Input range, resistive | 1...500 é, 2...1000 é, 4...2000 é, 8...4000 é |
Calibration methods | Factory calibrated, User-performed (optional) |
Data value during overload condition | Full scale, overrange flag, Data uncertain / data bad |
Resolution, thermocouple / millivolt | 16 bits at 10 Hz notch filter: <3.1 üV/cnt in ñ100 mV mode |
Wire impedance | 25 é maximum for specified accuracy (3-wire RTD mode only) |
HART handheld compliance | Add an external 250 é resistor into the current loop for HART transmitter compliance |
Insulation stripping length | 5069-RTB18-SPRING connections: 10 mm (0.39 in.), 5069-RTB18-SCREW connections: 12 mm (0.47 in.) |
Resolution, current | 16 bits at 10 Hz notch filter: 0...21 mA: <0.32 üA/count (16 bits), 3.6...21 mA: <0.27 üA/count (16 bits) |
Input notch filter (Hz) selections | 5, 10 (50/60 default), 15, 20, 50, 60, 100, 200, 500, 1000, 2500, 5000, 10000, 15625, 25000, 31250, 62500 |
Open circuit detection time, nom | Voltage: + full scale, <2 s, Current: 4...20 mA range, <2 s, RTD: <2 s, Thermocouple / millivolt: + full scale, <10 s |
Input type, RTD | 100, 200, 500, 1000 é platinum, alpha=385, 100, 200, 500, 1000 é platinum, alpha=3916, 120 é nickel, alpha=672, 100, 120, 200, 500 é nickel, alpha=618, 10 é copper 427 |
Resolution, voltage | 16 bits at 10 Hz notch filter: ñ10.5V: <320 üV/count (15 bits plus sign bipolar), 0...10.5V: <160 üV/count (16 bits unipolar), 0...5.25V: <80 ü/V count (16 bits unipolar) |
Resolution, RTD | (16 bits at 10 Hz notch filter) 3 wire mode: <7.9 mé/cnt in 1...500 é mode, <15.8 mé/cnt in 2...1000 é mode, <31.7 mé/cnt in 4...2000 é mode, <63.4 mé/cnt in 8...4000 é mode |
CJC inputs | Two CJC sensors, 2 thermistors embedded in 5069-RTB14CJC-(screw or spring) RTB, -or- 2 thermistors wired to 5069-RTB18-(screw or spring) RTB, Thermistor type: Measurement specialties, Inc. 10K3A1A, (for thermocouple mode use only) |
RTD sensor types/temperature range | 100, 200, 500, 1000 ohm PT 385: -200...870 ðC, -328...1598 ðF, 73...1143 ðK, 132...2058 ðR, 100, 200, 500, 1000 ohm PT 3916: -200...630 ðC, -328...1166 ðF, 73...903 ðK, 132...1626 ðR, 10 ohm CU 247: -200...260 ðC, -328...500 ðF, 73...533 ðK, 132...960 ðR, |
Thermocouple type/temperature range | Thermocouple Type B: 21â⬦1820 ðC, 68â⬦3308 ðF, 293â⬦2093 ðK, 528â⬦3768 ðR, Thermocouple Type C: 0â⬦2320 ðC, 32â⬦4208 ðF, 273â⬦2593 ðK, 492â⬦4668 ðR, Thermocouple Type D: 0â⬦2320 ðC, 32â⬦4208 ðF, 273â⬦2593 ðK, 492â⬦4668 ðR, Thermocouple Type E: -270â⬦1000 ðC, -454â⬦18 |
Width | 22 mm |
Height | 144.57 mm |
Depth | 105.42 mm |
Enclosure type | None (open-style) |
Surrounding air temperature, max | 60 ðC |
North American temperature code | T4 |
Operating temperature | 0 ðC |
Emissions | IEC 61000-6-4 |
ESD immunity | 6 kV contact discharges, 8 kV air discharges |
EFT/B immunity | ñ4 kV @ 5 kHz on power ports, ñ3 kV @ 5 kHz on shielded input ports |
Relative humidity | 5...95% noncondensing |
Conducted RF immunity | 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
Surge transient immunity | ñ1 kV line-line (DM) and ñ2 kV line-earth (CM) on power ports, ñ2 kV line-earth (CM) on shielded input ports |
Radiated RF immunity | 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz |
Nonoperating temperature | -40 ðC |
Voltage variation | 10 ms interruption on MOD power port |
SA power | 100 mA @ 18...32V DC |
SA power passthrough, max | 9.95 A @ 18...32V DC |
MOD power | 75 mA @ 18...32V DC |
MOD power passthrough, max | 9.55 A @ 18...32V DC |
RTB keying | None |
Weight | 175 g |
Vibration | 5 G @ 10...500 Hz |
Shock | Operating: 30 G, Non operating: 50 G |
Slot width | 1 |
DIN rail | Compatible zinc-plated chromate-passivated steel DIN rail, You can use the EN50022 - 35 x 7.5 mm (1.38 x 0.30 in) DIN rail |
Input impedance | Voltage: >1 Mé, Current: 90 é typical, 70â⬦110 é range, RTD: >1 Mé, Thermocouple/millivolt: >1 Mé |
Isolation voltage | 250V (continuous), basic insulation type, 50V Functional isolation between SA power and input ports, No isolation between individual input ports |
ATEX temp code | T4 |
IECEx temp code | T4 |
Description other products