Features | Usage | S3000 PROFINET IO does not have any local inputs or outputs and is only operated in a network with corresponding controller. | Model | Sensor without system plug | Application | Indoor | Protective field range | 5.5 m | Warning field range | 49 m (20 m at 20 % reflectivity) | Distance measuring range | 49 m | Number of simultaneously monitored protective fields | 2 | Type of field set | Dual field sets | Number of field sets | 8 | Number of fields | 16 | Number of monitoring cases | 16 | Scanning angle | 190° | Resolution (can be configured) | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm | Angular resolution | 0.5°, 0.25°, depending on range and resolution | Response time | 60 ms | Protective field supplement | 100 mm | Number of multiple samplings | 2 ... 16, configurable | Delay of automatic reset | 120 ms ... 4,920 ms, configurable |
|
Safety-related parameters | Type | Type 3 (IEC 61496) | Safety integrity level | SIL 2 (IEC 61508) | Category | Category 3 (EN ISO 13849) | Performance level | PL d (EN ISO 13849) | PFHD (mean probability of a dangerous failure per hour) | 8.0 x 10-8 | TM (mission time) | 20 years (EN ISO 13849) | Safe state in the event of a fault | The safety-related data is logic 0. |
|
Functions | Restart interlock | ✔ | Multiple sampling | ✔ | Monitoring case switching | ✔ | Simultaneous monitoring | ✔ | Static protective field switching | ✔ | Contour as a reference | ✔ | Integrated configuration memory | ✔ | Measured data output | Via RS-422 |
|
Interfaces | Connection type | | Bus connection | Copper conductor (2 female connectors for RJ-45 push-pull plug) | Supply connection | System plug with or without connecting cable |
| Configuration and diagnostics interface | RS-232 | Transmission rate | 9.6 kBaud, 19.2 kBaud, 38.4 kBaud |
| Fieldbus, industrial network | PROFINET PROFIsafe | Type of fieldbus integration | Integrated in the device | Device properties | PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2 | | PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4 | | Cycle time 4, 8, 16, 32 ms, etc. | | GSDML according to GSDML specification V2.25 | Switch properties | Filtering Data Base according to IEEE 802.1D | | 6 prioritization levels for IEEE 802.1Q – Network prioritization | | 64 KB SRAM memory for caching telegrams, managed in 768-byte segments | | Resource prioritization for network control and RTC2/3 frames | | Telegram extension based on "Cut-through" | | Port status (Disabled, Blocking, Forwarding) | | Support for non-real-time and real-time data transfer | Port properties | Auto-negotiation | | Auto-crossover (MDIX) | | Auto-polarity | | 100Base-TX | Conformance | Conformance Class B | Topology support | SNMP, MIB-2, LLDP according to IEEE 802.1AB | | MRP client support | Diagnostics | Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable | | Report system errors | | Cable diagnostics | | Neighborhood alerts | | Support for port statistics | | I&M support from I&M0 to I&M4 | Interfaces | TCP port 9000 and UDP port 30718 | | RS-232 | Functions that are not supported | Multicast communication | | Supervisor AR | | MAC-pause mechanism in full duplex | | Back-pressure in half duplex | | Static learning | | Broadcast Storm Control |
|
|
Electrical data | Protection class | III (VDE 0106, EN 60950) | Supply voltage Vs | 24 V DC (16.8 V DC ... 28.8 V DC) | Power consumption | ≤ 0.8 A |
|
Mechanical data | Dimensions (W x H x D) | 155 mm x 185 mm x 160 mm | Weight | 3.3 kg | Housing material | Aluminum die cast | Housing color | RAL 1021 (yellow) | Front screen material | Polycarbonate | Front screen surface finish | Outside with scratch-resistant coating |
|
Ambient data | Enclosure rating | IP65 (EN 60529) | Ambient operating temperature | –10 °C ... +50 °C | Storage temperature | –25 °C ... +50 °C | Vibration resistance | IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 | Class | 5M1 (IEC 60721-3-5) |
| Shock resistance | IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 | Class | 5M1 (IEC 60721-3-5) | Continuous shock | 50 m/s², 11 ms | | 100 m/s², 16 ms |
|
|
Other information | Type of light | Pulsed laser diode | Wave length | 905 nm | Detectable remission factor | 1.8 % ... > 1,000 %, reflectors | Laser class | 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1) |
|
Classifications | ECLASS 5.0 | 27272705 | ECLASS 5.1.4 | 27272705 | ECLASS 6.0 | 27272705 | ECLASS 6.2 | 27272705 | ECLASS 7.0 | 27272705 | ECLASS 8.0 | 27272705 | ECLASS 8.1 | 27272705 | ECLASS 9.0 | 27272705 | ECLASS 10.0 | 27272705 | ECLASS 11.0 | 27272705 | ECLASS 12.0 | 27272705 | ETIM 5.0 | EC002550 | ETIM 6.0 | EC002550 | ETIM 7.0 | EC002550 | ETIM 8.0 | EC002550 | UNSPSC 16.0901 | 39121528 |
|